Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

VENTS supplier in Romania

For VENTS we quote axial fans OVK, OV, VKF, VKOM and VPVO, centrifugal roof fans VKH, VKV and VKHC, smoke extraction fans and VUT ventilation units; for a quotation we need the series, size, air flow and voltage.

Headquarters: Boyarka, Kyiv region, Ukraine

Request a quote

Who is VENTS and what does it make?

VENTS is a Ukrainian manufacturer of ventilation equipment, based in Boyarka, in the Kyiv region. Its commercial and industrial lines include axial and centrifugal fans, smoke extraction fans, ventilation units with heat recovery and their accessories.

Axial fans are recognised by series. OVK and OVK EC are wall-mounted axial fans, OV and OV EC are also wall-mounted, OV1 and OVK1 have aluminium impellers and are also listed by the manufacturer among the wall-mounted axial fans, and VKF, VKOM and OVP are inline axial fans. The VPVO series comprises axial fans with an air flow of up to 120,000 m3/h; for smoke extraction there are the VDO series, with an aluminium impeller and fire resistance of 300 °C or 400 °C for 2 hours.

Centrifugal roof fans are made in the VKHC, VKV (vertical discharge), VKH (horizontal discharge) and VKMK series, with versions with EC motors. Commercial ventilation units with a polystyrene counterflow heat exchanger belong to the VUT series (for example VUT PE EC, VUT PBE EC, VUT PBW EC). The factory also makes grilles, diffusers, ducts, smoke dampers and electrical accessories. The range also includes inline fans for round and rectangular ducts, chimney fans, air curtains, destratification fans, heating and cooling coils, variable frequency drives and controllers. For a replacement, the exact series, size, air flow and motor voltage matter.

What do we supply from the VENTS range?

ProductDescription
OVK, OV, VKF, VKOM axial fansWall-mounted (OVK, OV, OV1, OVK1) and inline (VKF, VKOM, OVP) axial fans, with versions with EC motors. They are chosen by air flow, pressure, diameter and mounting conditions.
VPVO axial fans and smoke extraction fansVPVO are axial fans for air flows up to 120,000 m3/h. For smoke extraction there are the VDO series, with an aluminium impeller and 2-hour resistance at 300 °C or at 400 °C, including the VDO 1400 and 1600 sizes; VPVO 1400 and 1600 are the pressurisation versions.
Centrifugal roof fansVKHC and VKHC EC, VKV and VKV EC (vertical discharge), VKH and VKH EC (horizontal discharge) and VKMK. The EC versions reduce energy consumption through high-efficiency motors and continuous control.
VUT ventilation unitsCommercial units with counterflow heat recovery, in suspended versions (for example VUT PBE EC, VUT PBW EC and VUT 1500 PB EC) and vertical versions (VUT 300 E2V EC); VUT PE EC is a compact unit with an electric heater.

Why VENTS?

  • Wall-mounted and inline axial fans — OVK, OV, VKF, VKOM, OVP, with EC versions
  • Large VPVO axial fans — air flow up to 120,000 m3/h
  • Smoke extraction — aluminium impeller with fire resistance of 300 °C or 400 °C for 2 hours
  • Roof fans — VKH, VKV, VKHC with EC motors and horizontal or vertical discharge
  • VUT ventilation units — polystyrene counterflow heat exchanger, suspended and vertical versions

Which VENTS codes and series are requested most often?

CodeDescription
OVKWall-mounted axial fan
OVK ECWall-mounted axial fan with EC motor
OVWall-mounted axial fan
OV ECWall-mounted axial fan with EC motor
OV1Wall-mounted axial fan with aluminium impeller
OVK1Axial fan with aluminium impeller, for direct exhaust through the wall
VKFInline axial fan
VKOMInline axial fan
VPVOAxial fan for air flows up to 120,000 m3/h
VKHCCentrifugal roof fan
VKVCentrifugal roof fan with vertical discharge
VKHCentrifugal roof fan with horizontal discharge
VKMKCentrifugal roof fan
VUT PE ECCompact ventilation unit, with electric heater
VUT PBE ECCommercial ventilation unit, suspended version

Where is VENTS equipment used?

  • Commercial and industrial buildings — ventilation with inline and wall-mounted fans
  • Halls and warehouses — large VPVO axial fans
  • Smoke extraction and pressurisation — fire-resistant axial fans
  • Roofs and hall ventilation — VKH, VKV, VKHC centrifugal fans
  • Commercial buildings — VUT ventilation units with heat recovery

How do we supply VENTS in Romania?

From the VENTS range we can quote commercial and industrial axial and centrifugal fans, smoke extraction fans, VUT units and accessories. For a quotation, send the series and size from the nameplate, the air flow and pressure required, the voltage (230 V or 400 V, AC or EC), the type of mounting and, for smoke extraction, the fire resistance class. Items can ship in 24–72 h when the item is in stock, locally or at the supplier; the others we bring in to order, usually in 1–4 weeks, and the exact lead time is given in the quotation.

For smoke extraction fans we confirm the fire resistance class and the certifications required by the project before the quotation.

Frequently asked questions about VENTS

What does VENTS make?

VENTS makes axial and centrifugal fans, smoke extraction fans, ventilation units with heat recovery, grilles, ducts and accessories. The company is based in Boyarka, in the Kyiv region, in Ukraine.

How do I choose between an axial fan and a centrifugal roof fan?

Axial fans (OVK, VKF, VPVO) suit high air flows at low pressure. Centrifugal roof fans (VKH, VKV, VKHC) give more pressure and are mounted directly on the roof, with horizontal or vertical discharge. The air flow and the pressure loss in the network decide the choice.

What sizes, airflow rates and materials does the VENTS OVK1 axial fan series have?

The OVK1 series has four sizes, with duct connections of 150, 200, 250 and 315 mm. Maximum airflow is 180, 390, 1070 and 1700 m³/h respectively, at rated powers of 26, 33, 68 and 110 W. The impeller is aluminium and the casing is coated steel. We confirm the exact variant with the quotation.

Can I replace an old axial fan with a VENTS series?

We check the diameter, air flow, pressure, direction of rotation, voltage and type of mounting. If you send the nameplate of the old fan, we compare the data with the suitable series and confirm the replacement after checking.

What data do I send for a quotation on a VENTS OVK axial fan?

The series and size, the air flow and pressure required, the voltage, the type of mounting (wall, inline, roof) and, for smoke extraction, the temperature and the duration of fire resistance. For a VUT unit, add the air flow and the type of mounting.

How do I request a VENTS quotation?

Send the VENTS code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: VENTS (manufacturer documentation)