Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Pyroban supplier in Romania

Ex protection for vehicles and engines: ATEX conversions, kits, Hazpak packages

Headquarters: Shoreham-by-Sea (West Sussex), United Kingdom

Request a quote

Who is Pyroban and what does it make?

Pyroban is a British company from Shoreham-by-Sea, West Sussex, which has worked for more than 50 years on explosion protection for vehicles and engines used in classified areas. Its beginnings are tied to a project from 1969, born after an explosion caused by a diesel engine in a chemical plant. The company does not make forklift trucks: it takes well-known machines from other manufacturers and converts them for zone 1, 2, 21 or 22, keeping the original specification and ergonomics, so that the customer buys the brand they want. Conversions generally follow standards such as EN 1755, and the products have ATEX variants under Directive 2014/34/EU, according to the manufacturer's documentation.

The range is divided into four. Conversions of handling equipment: forklift trucks, pallet trucks, reach trucks and VNA trucks for zone 1 (category 2G, according to the manufacturer's documentation, with the Euromech 2G solutions for diesel and Ex-Tec 2G for electric), zone 2 (3G, active with system6000 gas detection or passive), and zones 21 and 22. Kits and packages for diesel engines intended for zone 2: Pyroban kits for branded engines, plus Hazpak packages, engines supplied with declared certification, from 100 to over 1100 bhp. Ex components and systems, including consultancy for ignition risk assessment. Gas detection on vehicles, for example Gascheka Zone 3, for areas adjacent to classified ones.

Typical uses are in chemical and petroleum warehouses, refineries, the paint and distillery industries and companies that operate drilling equipment and well services. For a quotation, the type of machine, the make and model, the target zone, the fuel (diesel or electric) and the required standard matter.

What do we supply from the Pyroban range?

ProductDescription
Zone 1 conversions (2G)Explosion-proof conversions for forklift trucks, pallet trucks, reach trucks and order pickers, in the Euromech 2G variants for diesel and Ex-Tec 2G for electric, only for diesel or electric vehicles.
Zone 2 (3G) conversions with system6000A package that combines gas detection with ignition protection, for diesel and electric forklift trucks of all types. A passive variant, without gas detection, also exists.
Engine kits and packages (Hazpak)Explosion-risk area kits for zone 2 diesel engines and Hazpak packages of 100, 200, 350, 500 and over 1100 bhp, from radiator to flywheel, standard or adapted to the project.
Gascheka Zone 3 and Ex componentsAuxiliary gas detection system for vehicles in areas adjacent to classified ones, plus Ex components and systems, ignition risk assessments and annual audits.

Why Pyroban?

  • Keeping the machine's brand — the conversion keeps the original specification and ergonomics of the forklift truck, pallet truck or reach truck
  • system6000 for zone 2 — combines gas detection with protection methods, for diesel and electric machines
  • Kits for branded diesel engines, in a version for explosion-risk areas — intended for zone 2 in well services and production, available for reference models
  • Hazpak packages from 100 to over 1100 bhp — engines supplied with declared certification, standard or customised, from radiator to flywheel
  • Gascheka Zone 3 — gas detection on any vehicle that crosses areas adjacent to classified ones

Which Pyroban codes and series are requested most often?

CodeDescription
system6000Conversion system for zone 2 with gas detection
Euromech 2GDiesel conversion for zone 1 (and 2)
Ex-Tec 2GElectric conversion for zone 1
Gascheka Zone 3Gas detection on vehicles, adjacent areas
Hazpak 100Engine package in a version for explosion-risk areas, over 100 bhp
Hazpak 200Engine package in a version for explosion-risk areas, over 200 bhp
Hazpak 350Engine package in a version for explosion-risk areas, over 350 bhp
Hazpak 500Engine package in a version for explosion-risk areas, over 500 bhp
Hazpak 1100Engine package in a version for explosion-risk areas, over 1100 bhp
ATEX 2GZone 1 conversions
ATEX 3GZone 2 conversions, active or passive
ATEX 2DZone 21 conversions
ATEX 3DZone 22 conversions

Where is Pyroban equipment used?

  • Chemical and petroleum warehouses — forklift trucks for zone 1 and 2
  • Oil and gas — diesel engines for well services and production
  • Cosmetics and pharmaceuticals — handling in areas with solvents
  • Paints, inks and distilleries — machines for areas with flammable vapours
  • Food and beverages — zones 21 and 22 with combustible dust

How do we supply Pyroban in Romania?

We can take requests for Pyroban components, kits and engine packages, as well as for conversions of handling equipment for explosion-risk areas. They are supplied to order; for kits and components the lead time is usually 1–4 weeks, while engine packages and vehicle conversions are configured projects, with a longer lead time, set in the quotation. For a correct proposal we need the make, model and series of the machine or engine, the fuel, the target zone (1, 2, 21 or 22), the gas or dust group and the temperature class. For spare parts, send the series of the converted equipment.

The feasibility of a conversion is assessed on the basis of the exact model of the machine, and converting a vehicle is a configured project, with the logistics set in the quotation.

Frequently asked questions about Pyroban

What products does Pyroban make?

Pyroban, from Shoreham-by-Sea (United Kingdom), makes conversions of forklift trucks and other machines for zones 1, 2, 21 and 22 (according to the manufacturer's documentation), Ex kits and packages for diesel engines (Hazpak), gas detection systems for vehicles and Ex components. The solution keeps the brand and specification of the base machine.

How do I choose between an active and a passive 3G conversion for zone 2?

The active variant uses system6000, with gas detection that warns the driver of an accidental leak, and is recommended by the manufacturer, as a rule, for zone 2. The passive one has no detection. The choice depends on the risk analysis of the site, which we ask for together with the machine data.

Can you supply Pyroban products in Romania and within what lead time?

Yes, to order. Kits and components usually take 1–4 weeks to order; vehicle conversions and engine packages are configured projects, so they have a longer lead time, confirmed in the quotation after the model and the zone are clarified.

Can I convert a machine I already have for an Ex zone?

Sometimes; we confirm it after checking. Send the make, model, year and series of the machine, the fuel (diesel or electric), the zone and the gas group. On the basis of these data we check feasibility; the vehicle logistics are set in the quotation.

What information do you need for a quotation for a Hazpak engine package?

The make and model of the engine wanted or the power required in bhp (from 100 to over 1100), the zone (zone 2 for kits), the application, the gas group and the temperature class, and whether the package must be standard or adapted to the project. With these the power class is chosen.

How do I request a Pyroban quotation?

Send the Pyroban code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Pyroban Ltd (manufacturer documentation)