Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

RSP supplier in Romania

For RSP we quote trackside worker warning systems (ATWS, SATWS, TAWS, SCWS, LOOWS), steel or GRP location cases, REB relocatable equipment buildings and Magshields covers for 2BA terminals; for a quotation we need the standard required, the dimensions and the material.

Headquarters: Saltash, United Kingdom

Request a quote

Who is RSP and what does it make?

RSP (Rail Signalling and Power) is a British manufacturer of equipment for railway signalling and power distribution, with its factory at Saltash, in Cornwall. We quote trackside worker warning systems, location cases for signalling equipment, relocatable equipment buildings (REB) and protective covers for 2BA terminal blocks. The equipment is designed to British railway standards, so it suits projects that explicitly require them.

The warning systems cover several working principles: semi-automatic (SATWS), automatic (ATWS), train approach (TAWS), signal-controlled (SCWS) and lookout-operated (LOOWS); they are supplied with housings for the control system, cabinets, disconnection boxes, mounting posts and trackside audible warning units. The location cases are made of mild steel, galvanised steel, stainless steel or GRP, empty or fitted out, for schemes with SSI electronic interlocking, with extra-deep, tunnel or anti-vandal variants. REB buildings are made to the BR1615D specification, in type sizes 1–9, and are factory tested to 3A and/or BS EN 61439. Magshields covers are fitted over existing 2BA terminals, to NR/L2/SIG/11201 Mod B3, with 4 mm holes for testing.

For an accurate quotation, what matters is the standard required by the project, the type of warning system, the dimensions and material of the cabinet or building, the internal configuration, the RAL colour, the factory tests required and the place of installation on the track.

What do we supply from the RSP range?

ProductDescription
Trackside worker warning systemsSATWS, ATWS, TAWS, SCWS and LOOWS systems, with housings for the control system, cabinets, disconnection boxes, mounting posts and trackside audible warning units. Design, construction and factory acceptance testing (FAT) for each project.
Location casesCabinets for signalling, telecommunications and electrification equipment, in mild steel, galvanised steel, stainless steel or GRP, empty or fitted out, including SSI, extra-deep, tunnel and anti-vandal variants, with colour bands and LEMUR-AG15 coating.
REB relocatable equipment buildingsRelocatable equipment buildings to the BR1615D specification, in type sizes 1–9, with BRSM440 racking. They are supplied empty, partly or fully fitted out, in RAL colours (olive green, grey), factory tested to 3A or BS EN 61439.
Magshields covers for 2BA terminalsProtective covers that cover existing 2BA terminals and give protection against touching live parts, without replacing the terminals. They comply with NR/L2/SIG/11201 Mod B3 and have 4 mm holes for testing with the cover fitted.

Why RSP?

  • Five types of warning system — SATWS, ATWS, TAWS, SCWS and LOOWS — for the protection of staff working on the track
  • Location cases in mild steel, galvanised steel, stainless steel or GRP — the material is chosen by environment and by project requirements
  • REB buildings to BR1615D, type sizes 1–9 and 3A or BS EN 61439 factory testing — supplied empty, partly or fully fitted out
  • Magshields covers for 2BA terminals — touch protection fitted over the existing terminals, with 4 mm test holes
  • Design, construction and factory testing in a single programme — housings, cabinets, disconnection boxes and posts

Which RSP codes and series are requested most often?

CodeDescription
SATWSSemi-automatic warning system for trackside workers
ATWSAutomatic warning system for trackside workers
TAWSTrain approach warning system
SCWSSignal-controlled warning system
LOOWSLookout-operated warning system
LOCLocation case in steel or GRP
SSI LOCLocation case for schemes with SSI electronic interlocking
REBRelocatable equipment building, BR1615D, types 1–9
MagshieldsProtective cover for 2BA terminals, NR/L2/SIG/11201 Mod B3
LEMUR-AG15Coating for reducing the solar effect on cabinets

Where is RSP equipment used?

  • Railways — warning systems for work on the track
  • Railway signalling — location cases for SSI schemes
  • Electrification and installations — relocatable equipment buildings
  • Signalling maintenance — covers for existing 2BA terminals
  • Railway infrastructure — housings, disconnection boxes and mounting posts

How do we supply RSP in Romania?

From the RSP range we can quote warning systems for trackside work, location cases, relocatable equipment buildings and covers for 2BA terminals. For an accurate quotation, send the standard required by the project, the type of system or case, the dimensions, the material (steel or GRP), the internal configuration, the RAL colour and the factory tests needed. For existing parts, the code or a photo helps. RSP equipment is supplied to order, usually in 1–4 weeks. For systems designed on request, depending on the specification, the lead time can be longer. The exact lead time appears in the quotation.

The product is designed for British railway standards; compliance with other railway standards is checked separately, on request.

Frequently asked questions about RSP

What does RSP make?

At Saltash, RSP makes warning systems for trackside workers (SATWS, ATWS, TAWS, SCWS, LOOWS), location cases, relocatable equipment buildings and covers for 2BA terminals, plus power distribution equipment. Our offer is limited to the railway signalling products.

How do I choose between ATWS, TAWS and LOOWS systems?

ATWS works automatically, SATWS is semi-automatic, TAWS warns on the approach of a train, SCWS is signal-controlled and LOOWS is operated by a lookout. The choice depends on the working procedure on the track. Send us the type of work, the length of the section and the checking requirements.

Can you supply RSP equipment in Romania and how soon?

Yes, to order: equipment usually arrives in 1–4 weeks. For systems designed on request, depending on the specification, the lead time can be longer. Small spare parts can ship in 24–72 h when the item is in stock, locally or at the supplier. We confirm the exact lead time in the quotation.

I have a location case or 2BA terminals in an old installation; what data do you need?

For a case: the dimensions, the material (steel or GRP), the internal scheme and the standard followed. For 2BA terminals: the type of terminal block, the number of terminals and the installation conditions. A photo of the installation helps to establish the suitable item for your configuration.

What do I need to state for a quotation on an REB relocatable equipment building?

The type size (1–9), the BR1615D or project specification, the RAL colour, the equipment to be fitted, whether you want the building empty, partly or fully fitted out, and the factory test required (3A or BS EN 61439). Tell us the installation site as well.

How do I request a RSP quotation?

Send the RSP code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: RSP (manufacturer documentation)