voestalpine Signaling supplier in Romania
UniAC[2] axle counters, switch drives and zentrak monitoring
Who is voestalpine Signaling and what does it make?
voestalpine Signaling brings together signalling, switch drive and monitoring activities, with companies in Germany (Siershahn), Austria and Poland. The range includes axle counting systems (UniAC), switch drive and locking mechanisms (HYDROSTAR, UNISTAR), end position detectors, switch heating systems and diagnostic and monitoring technologies for infrastructure and rolling stock under the zentrak brand. For a railway infrastructure engineer, the interest lies in the parts and systems for stations and lines: switch drives with locking, wheel sensors and end position detectors.
The UniAC[2] axle counting system has functional safety according to the manufacturer's documentation, a modular architecture and can be installed centrally, in a signalling room, or decentralised, next to the track, which shortens the cables between the wheel sensors and the modules. It is powered from 18 to 72 V DC, complies with EULYNX Baseline 4 version 3 and NEUPRO, has relay, optocoupler or serial protocol interfaces and a 20 mA current loop, and a single module type can perform all functions, depending on the configuration. The UniAS[2] wheel sensor has a cable with a connector, with no electronics on the track.
The switch drive and locking family includes the HYDROSTAR and UNISTAR COMPACT operating systems with integrated locking, the UNISTAR CSV 34 mechanism, the HYDROLINK force transmission system, the SPHEROLOCK Classic lock, the EPD 4.0, IE2010 and UNISTAR ELP end position detectors and the PHS 1601 heating system. Under zentrak there are hot axle box and hot wheel detectors, detectors for wheels with defects and dragging equipment, and weighing in motion.
What do we supply from the voestalpine Signaling range?
| Product | Description |
|---|---|
| UniAC[2] — axle counting system | System with functional safety, with a modular architecture, 18–72 V DC supply, relay, optocoupler or serial interfaces, 20 mA current loop and EULYNX Baseline 4 version 3 compliance, according to the manufacturer's documentation. It includes a configuration tool (Application Architect) and diagnostics with online storage of analogue signals. |
| Switch drive and locking systems | The HYDROSTAR and UNISTAR COMPACT family for operation with integrated locking, the UNISTAR CSV 34 mechanism, the HYDROLINK force transmission system and the SPHEROLOCK Classic lock, completed by end position detectors (EPD 4.0, IE2010, UNISTAR ELP). |
| PHS 1601 — switch heating | Switch heating system, part of the switch control and heating family, alongside cable fixing and protection systems (protection channel, excess cable cabinet, SDK 02 rail plug). |
| zentrak — diagnostics and monitoring | Monitoring ecosystem for infrastructure and rolling stock: modular diagnostic system, automatic vehicle identification, derailment detection, hot axle box and hot wheel detectors, detection of wheels with defects and dragging equipment, weighing in motion and visual train analysis. |
Why voestalpine Signaling?
- UniAC[2], with functional safety according to the manufacturer's documentation — central or decentralised installation, with a single module type that performs all functions
- EULYNX Baseline 4 version 3 compliance — safe communication with the interlocking without external cryptographic devices
- UniAS[2] wheel sensor with a cable with a connector and no electronics on the track — fewer maintenance items in the field
- Separate families for switch drive and locking (HYDROSTAR, UNISTAR, HYDROLINK, SPHEROLOCK) — solutions for track with or without external locking
- zentrak monitoring with detectors for axle boxes, hot wheels and wheels with defects — modular systems, extended over time
Which voestalpine Signaling codes and series are requested most often?
| Code | Description |
|---|---|
| UniAC[2] | Axle counting system with functional safety, 18–72 V DC |
| UniAC[1] | Previous generation of axle counting system |
| UniAS[2] | Wheel sensor with cable with connector |
| UNIOC | Object controller platform |
| HYDROSTAR | Switch operating system with integrated locking |
| UNISTAR COMPACT | Compact switch operating system |
| UNISTAR CSV 34 | Switch drive mechanism |
| HYDROLINK | Force transmission system for switches |
| SPHEROLOCK Classic | Switch locking system |
| EPD 4.0 | End position detector |
| IE2010 | End position detector |
| UNISTAR ELP | End position detector |
| PHS 1601 | Switch heating system |
| SDK 02 | Double-sided rail plug |
Where is voestalpine Signaling equipment used?
- Railway infrastructure — axle counting and detection of track section clearance
- Stations and switches — drives with locking, end position detectors and heating
- Rolling stock monitoring — hot axle box and wheel-with-defect detectors
- Railway asset management — condition data and predictive maintenance
How do we supply voestalpine Signaling in Romania?
We can quote voestalpine Signaling components and spare parts for existing installations: wheel sensors, axle counter modules, end position detectors and switch drive elements. Parts are supplied to order; the lead time is usually 1–4 weeks for parts, while for systems configured for a station it can be longer and is confirmed in the quotation. For a correct quotation we need the name and the code from the nameplate (for example UniAS[2], EPD 4.0 or UNISTAR), the type of switch or interlocking, the supply voltage and the number of counting points.
The compatibility of a part with an older generation of the system is determined on the basis of the exact code and the installation diagram.
Frequently asked questions about voestalpine Signaling
What product range does voestalpine Signaling have?
voestalpine Signaling makes UniAC axle counting systems, HYDROSTAR and UNISTAR switch drive and locking mechanisms, end position detectors, switch heating and zentrak monitoring systems.
How do I choose between central and decentralised installation for UniAC[2]?
Central installation, in a signalling room, brings the electronics for the whole station together, while decentralised installation, next to the track, shortens the cables to the wheel sensors. The choice depends on the station geometry, the length of the sections and the interlocking the system connects to.
Do you supply voestalpine Signaling components in Romania and within what lead time?
Yes, voestalpine Signaling parts are supplied to order, usually in 1–4 weeks, and systems configured for a station can have a longer lead time; the exact value is confirmed in the quotation.
What replaces an older IE2010 end position detector?
The current range includes EPD 4.0 and UNISTAR ELP, but equivalence is confirmed after checking: the mechanism type, the mounting and the interface matter. Send the code from the existing detector and the switch data, and we check the suitable variant.
What do I need to send for a quotation for a UniAC[2] axle counting system?
The number of counting points and sections, the rail type, the interlocking and the interface required (relay, optocoupler or serial), the supply voltage and whether it is an extension of an existing UniAC system, in which case add the module codes.
How do I request a voestalpine Signaling quotation?
Send the voestalpine Signaling code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.