ICF Ingeniería y Control Ferroviario supplier in Romania
Axle counters, LED signals and SIL 4 level crossing protection
Headquarters: Alcobendas (Madrid), Spain
Who is ICF Ingeniería y Control Ferroviario and what does it make?
ICF Ingeniería y Control Ferroviario is a Spanish manufacturer of railway signalling equipment, started in Madrid and headquartered in Alcobendas. The company designs, manufactures, installs and maintains axle counters, LED light signals, level crossing protection systems and safety solutions for trackside personnel, all with functional safety and certifications according to the manufacturer's documentation. For a signalling engineer, level crossings and axle counters are relevant: they are long-life infrastructure equipment, replaced selectively on low-traffic lines or when renovating old systems with track circuits.
The AC-900 axle counter connects a track section of up to 8 km over a bus, with the entire electronic system centralised in the cabin, and operates at speeds from 0 to 400 km/h. A single 19-inch, 6U rack can host 96 SDE-900 sensors and 96 track sections, configured by software only. The SDE-900 sensor has three coils, IP68 protection with immersion down to 2 m, a temperature range from -40 to 85 °C and resistance to vibration and shock. The SPN-900 level crossing protection can operate in the wireless-photovoltaic version, without civil works, with autonomy of up to 60 days without energy input.
The SLS-900 LED signals cover 1–5 aspects, in red, yellow, green, blue, white and violet, with a supply of 6, 12, 24 or 48 V DC or 110/220 V AC and lenses of 120–300 mm, while the SALS-900 are alphanumeric signals with 7 or 16 segments. They are of interest for level crossing renovations, low-traffic lines and trackside work zones.
What do we supply from the ICF Ingeniería y Control Ferroviario range?
| Product | Description |
|---|---|
| AC-900 and SDE-900 — axle counters and sensors | The AC-900 counter connects track sections of up to 8 km over a bus, at speeds from 0 to 400 km/h, and a 19-inch 6U rack can manage 96 SDE-900 sensors and 96 sections. The sensor also measures the axle speed, with functional safety, up to 450 km/h. |
| SPN-900 — level crossing protection | A modular system with functional safety for level crossings, without electromechanics, with automatic or interlocking operation and a single 4 × 1.4 mm cable for warning and signal pedal. The wireless-photovoltaic version uses SDE-900 sensors and signals linked through a VHF channel, solar powered. |
| SLS-900 and SALS-900 — LED signals | The SLS-900 is the LED traffic signal, with 1–5 aspects, lenses of 120–300 mm, a supply of 6–48 V DC or 110–220 V AC and a power of 5–20 W. The SALS-900 is the alphanumeric version, with fixed pictograms, speed indicators and variable information panels with 7 or 16 segments. |
| SPO-900 and SPA-900 — personnel and pedestrian safety | The SPO-900 protects trackside workers, with an audible signal above 120 dB, a light intensity above 200 cd and batteries with 48 h autonomy. The SPA-900 is a standalone system for pedestrian crossing between platforms, built from already certified technologies. |
Why ICF Ingeniería y Control Ferroviario?
- AC-900 axle counter with a bus of up to 8 km, with functional safety according to the manufacturer's documentation — the electronics stay in the cabin and only the sensors remain on the track
- SDE-900 sensor with IP68 (2 m immersion), -40…85 °C, three coils — reliability in harsh environments
- SPN-900 level crossing in the wireless-photovoltaic version — no civil works and no cable, with autonomy of up to 60 days without energy
- SLS-900 LED signals, 1–5 aspects — compatible with existing interlockings and with the incandescent lamps already installed
- SPO-900 system for protecting trackside workers — audible signal above 120 dB, batteries with 48 h autonomy, installation in under an hour
Which ICF Ingeniería y Control Ferroviario codes and series are requested most often?
| Code | Description |
|---|---|
| AC-900 | Axle counter with functional safety, bus of up to 8 km |
| SDE-900 | Axle detection sensor, IP68, -40…85 °C |
| SPN-900 | Level crossing protection system, with functional safety |
| SPN-900 wireless-fotovoltaic | Level crossing without cable and without civil works |
| SLS-900 | LED traffic signal, 1–5 aspects |
| SALS-900 | Alphanumeric signal with 7 or 16 segments |
| SPO-900 | Trackside worker protection system |
| SPA-900 | Standalone system for pedestrian crossing between platforms |
Where is ICF Ingeniería y Control Ferroviario equipment used?
- Railway infrastructure — axle counters and sensors for track section detection
- Level crossings — automatic systems with functional safety or linked to the interlocking
- Low-traffic lines — replacing track circuits with axle counters
- Trackside works — warning signals for personnel
How do we supply ICF Ingeniería y Control Ferroviario in Romania?
We can quote, to order, ICF axle sensors, counter components and signals for existing railway signalling installations or for extensions. Components are supplied to order, usually in 1–4 weeks, while level crossing systems configured per project may take longer and this is specified in the quotation. For identification, it helps us to have the type and code on the equipment (for example SDE-900, SLS-900), the supply voltage, the type of interlocking the installation connects to and the number of tracks at the level crossing.
Compatibility with a particular interlocking is established on the basis of the installation's technical documentation.
Frequently asked questions about ICF Ingeniería y Control Ferroviario
What products does ICF Ingeniería y Control Ferroviario make?
ICF, a Spanish company from Alcobendas, makes railway signalling equipment: AC-900 axle counters with SDE-900 sensors, SPN-900 level crossing protection systems, SLS-900 and SALS-900 LED signals, and safety systems for workers and pedestrians.
How do I choose between a classic SPN-900 level crossing and the wireless-photovoltaic one?
The wired version is chosen where a cable route and a power supply already exist. The wireless-photovoltaic one suits hard-to-reach locations or places without a power network, since it removes civil works and cable, with autonomy of up to 60 days without energy. The number of tracks and the lighting conditions matter.
Do you supply ICF equipment in Romania and how fast?
Yes, ICF equipment is supplied to order. Components are supplied to order, usually in 1–4 weeks, while systems configured per project may have a longer lead time; the exact value is confirmed in the quotation.
Can the AC-900 replace track circuits on a low-traffic line?
ICF axle counters are used to renovate track circuits on low-traffic lines, but a replacement requires checking the interlocking, the section lengths and the track conditions. Send the diagram of the existing installation and the type of interlocking for review.
What data do I need to send for a quotation on SLS-900 signals?
The number of aspects, the colours needed, the lens diameter (120–300 mm), the supply voltage (6–48 V DC or 110–220 V AC), the power required by the interlocking and, for replacements, a photo of the existing signal and of its nameplate.
How do I request a ICF Ingeniería y Control Ferroviario quotation?
Send the ICF Ingeniería y Control Ferroviario code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: ICF Ingeniería y Control Ferroviario (manufacturer documentation)