Richard AG supplier in Romania

Rail pantographs, vacuum circuit breakers and earthing switches

Founded in 1906 · Headquarters: Murgenthal, Switzerland

Request a quote

Who is Richard AG and what does it make?

Richard AG is a Swiss, owner-managed company based and manufacturing in Murgenthal that develops, manufactures and assembles power supply components for rail vehicles: pantographs, vacuum circuit breakers, earthing switches and roof systems. The company's history dates back to 1906, it has around 130 employees and quality certifications according to the manufacturer's documentation. For a rolling stock engineer, the relevant part is spare parts and upgrades for electric locomotives, multiple units and trams: the pantograph that collects current from the contact line, the vacuum circuit breaker that disconnects the vehicle from the supply, and the earthing switch used for work in the workshop.

The generation 3 main-line pantographs are designed without welds, with optimised aerodynamics and noise, for nominal voltages of 3 kV DC and 15–25 kV AC, current up to 2500 A and speeds up to 250 km/h. The ADD system automatically lowers the pantograph when the contact strip or slider is damaged, and a contact strip heater is optional for DC networks. The Gen 2 and Gen 3 tram pantographs work up to 3 kV DC and 80 km/h, in three design versions. The vacuum circuit breakers for 15–25 kV AC, 800–1000 A and 200 km/h come in an electric version, with phase-synchronised switching, and a lighter pneumatic version.

The range also includes the charging pantograph for battery vehicles, rated 1000–2000 A DC, with a winter heating system, earthing switches for 0.75–3 kV DC and 11–25 kV AC, with current from 120 to 4000 A, and complete roof boxes.

What do we supply from the Richard AG range?

ProductDescription
Main-line pantographs Gen 2 and Gen 3Modular pantographs for locomotives and trains, at 3 kV DC and 15–25 kV AC, current up to 2500 A, speed up to 250 km/h for Gen 3. Gen 3 eliminates welds, has an aerodynamic shape, ADD and an optional contact strip heater for DC networks.
Tram pantographs Gen 2 and Gen 3Modular roof pantographs for urban transport, in three design versions, up to 3 kV DC and 80 km/h. They have low-profile insulators for compact mounting, ADD and, optionally, contact force sensors that control lowering of the slider.
Vacuum circuit breakers for locomotivesMain switching and isolating elements between the contact line and the vehicle equipment, at 15–25 kV AC, 800–1000 A, up to 200 km/h. Electric version, with phase-synchronised switching and no pneumatic line, or lighter pneumatic version; both with earthing switch and an adapter for connections.
Charging pantograph and earthing switchesThe charging pantograph serves battery vehicles at fast-charging stations, at 1000–2000 A DC, with thermostat-controlled heating. The earthing switches (for example those with codes RM 5169 and RM 5200-303) cover 0.75–3 kV DC and 11–25 kV AC.

Why Richard AG?

  • Gen 3 pantographs without welds, 3 kV DC and 15–25 kV AC, up to 2500 A and 250 km/h — also suitable for upgrades
  • ADD system and optional contact force sensors — they lower a damaged pantograph automatically, which limits damage to the contact line
  • Electric or pneumatic vacuum circuit breaker, 15–25 kV AC — the electric version switches in phase synchronisation and needs no air line
  • Charging pantograph 1000–2000 A DC with heating — stable contact at charging stations in winter
  • Manual, pneumatic or electric earthing switches, 120–4000 A — safety of personnel during inspections and work

Which Richard AG codes and series are requested most often?

CodeDescription
Full Track Gen 2Main-line pantograph, second generation
Full Track Gen 3Main-line pantograph, 3 kV DC / 15–25 kV AC, 2500 A
Tram Gen 2Tram pantograph, second generation
Tram Gen 3Tram pantograph, up to 3 kV DC and 80 km/h
RM 5169Mechanical earthing switch with Hirsch switch
RM 5200-303Compact, withdrawable earthing switch
ADDAutomatic pantograph lowering device

Where is Richard AG equipment used?

  • Electric locomotives and multiple units — pantographs and vacuum circuit breakers
  • Trams and urban transport — modular roof pantographs
  • Battery-powered rail vehicles — charging pantographs with heating
  • Maintenance workshops — earthing switches for personnel safety

How do we supply Richard AG in Romania?

We can quote Richard AG components for rolling stock in service: pantographs, contact strips, vacuum circuit breakers, earthing switches and spare parts. Parts are supplied to order, usually in 1–4 weeks, while pantographs or circuit breakers configured for a vehicle may take longer, confirmed in the quotation. For an accurate quotation, the following are useful: vehicle type and series, network voltage (3 kV DC, 25 kV AC, etc.), rated current, working height, the code on the nameplate of the existing unit and the roof mounting interface.

Compatibility of a part with an older pantograph or circuit breaker is established from the original nameplate or the mounting drawing.

Frequently asked questions about Richard AG

What product range does Richard AG have?

Richard AG, a Swiss company from Murgenthal with a history dating back to 1906, manufactures main-line and tram pantographs, vacuum circuit breakers for locomotives, charging pantographs, earthing switches and complete roof systems for rail vehicles.

How do I choose a Richard AG pantograph for a locomotive?

Start from the network voltage (3 kV DC or 15–25 kV AC), the required rated current, the maximum speed and the roof clearance. Gen 3 covers up to 2500 A and 250 km/h; for trams there are dedicated versions up to 3 kV DC and 80 km/h.

Can you supply Richard AG components in Romania and within what lead time?

Yes, Richard AG components are supplied to order. For parts, the lead time is usually 1–4 weeks, while pantographs and circuit breakers configured for a vehicle may have a longer lead time; the exact value is confirmed in the quotation.

Can an electric vacuum circuit breaker replace a pneumatic one?

The electric version needs no pneumatic line and switches in phase synchronisation, but replacement depends on the mounting interface, the rated currents and the vehicle control. Equivalence is confirmed from the data: send the nameplate of the existing unit and the vehicle series.

What data do you need for a quotation on an earthing switch?

Rated voltage and current, the type of actuation (manual, pneumatic or electric), the mounting position, the code on the nameplate (for example RM 5169) and, for a replacement, a photo of the existing unit and of the terminals.

How do I request a Richard AG quotation?

Send the Richard AG code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote