Who is Rugged Monitoring and what does it make?

Rugged Monitoring is a company based in Canada, specialised in IoT sensors, local data collection devices and an asset management software suite called RM EYE, for monitoring the condition of electrical equipment. The products cover transformers, power cables, GIS switchgear, rotating machines and medium-voltage cells. The common idea is measurement with sensors immune to electromagnetic interference, even in environments where ordinary electronics would give false readings.

For transformers, the range is divided into four directions. The first is fibre optic temperature: TSENS probes with a GaAs (gallium arsenide) element, 9 mm discs for windings, core, busbars or tap changers, versions with Kevlar sheath or with fluorescence, as well as the T301, T401, T501 and D501FL monitors. The second is partial discharge, with UHF sensors for the tank, valves and bushings, UHF and HF monitors and a combined UHF with HF system. The third is bushing monitoring, by means of the BSENS sensor and the BM201 system. The fourth is hydrogen and DGA, with the GSENS H2 sensor and the GSENS2 system.

In Romania, such a system is justified on power transformers in 110–400 kV substations, on reactors and on rotating machines in power plants. Whoever already has sensors installed asks whether the new monitors can be connected to them; whoever builds a transformer asks which probes can be inserted in the winding. The answer depends on the type of fibre, the connectors and the number of channels, so on data that we ask for at the quotation stage.

What do we supply from the Rugged Monitoring range?

ProductDescription
TSENS and LSENSFibre optic temperature probes: TSENS for dry or oil-filled transformers, TSENS-K with Kevlar sheath, TSENS-FL with fluorescence, LSENS-T for high temperatures and LSENS-U for harsh conditions. They resist solvents and have a PTFE sheath.
T301 / T401 / T501 / D501FLFibre optic temperature and condition monitors for several assets. T301 is multichannel for GaAs and fluorescence, T401 and T501 are multichannel condition monitors, and D501FL is dedicated to fluorescence probes.
USENS, PD201 / PD211, UPM601 / HPM601 / CPM601UHF sensors for valves and tank (USENS-T, USENS-V), for bushings (USENS-BT) and partial discharge monitors: UHF, HF or combined UHF with HF, in continuous or portable versions.
BSENS / BM201 / GSENS H2 / GSENS2BSENS and BM201 form the transformer bushing monitoring. GSENS H2 is a dissolved hydrogen sensor, and GSENS2 a DGA monitoring system, both for tracking fault gases in oil.

Why Rugged Monitoring?

  • TSENS probes with GaAs, without calibration and without drift over time — winding temperature remains repeatable over the life of the transformer
  • 9 mm discs in Kevlar, fluorescence or high-temperature versions — the probe is chosen according to the place in the winding
  • Monitors with NIST calibration certificate (T301, O201) — usable in the laboratory and in heat-run tests, not only in service
  • UHF sensors for valves, tank and bushings — the same partial discharge architecture across the whole transformer
  • RM EYE platform with more than 14 interconnected modules — temperature, discharge, bushing and DGA data in a single environment

Which Rugged Monitoring codes and series are requested most often?

CodeDescription
TSENSFibre optic temperature probe with GaAs, 9 mm disc
TSENS-KProbe with Kevlar sheath for transformers
TSENS-FLFluorescence temperature probe
LSENS-TTemperature probe for high values
LSENS-UTemperature probe for harsh conditions
T301Multichannel temperature monitor (GaAs and fluorescence)
O201Fluorescence temperature monitor
H201Portable fibre optic temperature monitor
T401Multi-asset condition monitor
T501Multichannel condition monitor
D501FLTemperature monitor for fluorescence probes
USENS-TUHF partial discharge sensor for the tank valve
USENS-BTPartial discharge sensor for bushings
BM201Online bushing monitoring system
GSENS H2Dissolved hydrogen sensor for transformers
GSENS2DGA monitoring system

Where is Rugged Monitoring equipment used?

  • Power transformers and reactors — hot spot temperature, partial discharge, bushings and DGA
  • Power cables — partial discharge and thermal stress
  • GIS — UHF sensors for partial discharge in gas-insulated switchgear
  • Rotating machines in power plants and industry — temperature, vibration and electrical stress
  • Medium-voltage cells and energy storage — condition tracking with IoT sensors

How do we supply Rugged Monitoring in Romania?

We can quote temperature probes and monitors, partial discharge sensors and bushing or DGA systems from the Rugged Monitoring range. Orders are usually fulfilled in 1–4 weeks; multichannel systems may have a longer lead time, confirmed in the quotation. A correct request includes the type of asset, the voltage, the number of channels, the type of fibre and the existing connectors, the interface wanted to SCADA and whether the sensors are installed in the factory or on equipment already in service.

The availability of a probe with non-standard length or sheath depends on the complete specification of the mounting point.

Frequently asked questions about Rugged Monitoring

What products does Rugged Monitoring make?

The company, based in Canada, makes IoT sensors, local data collection devices and the RM EYE suite for monitoring electrical equipment. Its products include TSENS fibre optic temperature probes, UHF and HF partial discharge monitors, bushing systems and hydrogen sensors.

How do I choose the TSENS, TSENS-K or TSENS-FL probe?

TSENS is the standard probe with a GaAs element, TSENS-K has a Kevlar sheath for mechanical protection, and TSENS-FL works on the fluorescence principle. The choice depends on the type of monitor, the place in the winding and the length of the fibre; send us the drawing of the winding or the specification of the transformer.

Can you supply Rugged Monitoring equipment in Romania and in what time?

Yes, we supply Rugged probes and monitors to order. The lead time is usually 1–4 weeks, longer for multichannel systems. We confirm the availability of a specific model before the quotation and state it explicitly in the final document.

Can I connect a Rugged monitor to probes already installed?

Sometimes, but compatibility depends on the type of fibre (GaAs or fluorescence), the connectors and the protocol. Equivalences between makes are confirmed from the codes. Send us the make and code of the existing probes and the number of channels, and we check the configuration before the quotation.

What information do you need for a monitoring system quotation?

Send the type of asset (transformer, cable, GIS, rotating machine), the rated voltage, the quantities to be tracked, the number of channels and the integration protocol. For transformers, a sketch with the valves, the bushings and the available mounting points greatly shortens the check.

How do I request a Rugged Monitoring quotation?

Send the Rugged Monitoring code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote