Siemens Electrical supplier in Romania
Electrical technology for industry and buildings
Founded in 1847 · Headquarters: Munich, Germany
Who is Siemens Electrical and what does it make?
Siemens Electrical means low-voltage switchgear for electrical panels: SENTRON 5SL modular circuit breakers, SIRIUS 3RT2 contactors, 3RV2 motor protection circuit breakers, 3RW soft starters and SIVACON distribution boards. They are used in residential, commercial and industrial panels, for circuit protection and for starting pump and fan motors. For panels in Romania we can quote the components starting from the single-line diagram.
Modular circuit breakers are chosen by breaking capacity: the 5SL3 series has 4.5 kA, 5SL6 has 6 kA and 5SL4 has 10 kA, all to IEC/EN 60898-1 and with a width of one module per pole. The 5SL6 covers 0.3–63 A with B and C characteristics, and the 5SL4 adds the D characteristic. For motors, the 3RT2 contactors and 3RV2 circuit breakers are built on the same four sizes, S00, S0, S2 and S3, and the size can be read directly from the digits of the code.
On the digital side, the 5SL6 COM circuit breakers record energy and status data, and the Powercenter 1100 collects data from up to 24 devices and transmits it via Modbus TCP. For large panels, the SIVACON S4 reaches 4,000 A (6,300 A with the extended licence option), with design verification to IEC 61439.
What do we supply from the Siemens Electrical range?
| Product | Description |
|---|---|
| SENTRON 5SL modular circuit breakers | The 5SL3 (4.5 kA), 5SL6 (6 kA, 0.3–63 A, B and C characteristics) and 5SL4 (10 kA, B, C and D characteristics) are described by Siemens for meter panels and small distribution boards in residential and commercial buildings. The breaking capacity is chosen according to the short-circuit current at the point of installation. For industrial applications, Siemens points to the 5SY series, with a breaking capacity of up to 25 kA on rated currents of 0.3–80 A. The 5SL6 COM variant records energy and status data. |
| SIRIUS 3RT2 contactors and 3RV2 motor protection circuit breakers | The size can be read from the code: in 3RT2015 and 3RV2011 the sixth position in the code shows the size (1 = S00, 2 = S0, 3 = S2, 4 = S3). Contactors are chosen by motor power and coil voltage; at size S00, for example, -1AP0 means a 230 V AC coil, and -1BB4 a 24 V DC coil. On the 3RV2, the current setting range is encoded in the code: 3RV2011-1KA10 sets 9–12.5 A (S00), and 3RV2041-4MA10 sets 80–100 A (S3). |
| SIRIUS 3RW30 and 3RW40 soft starters | The 3RW30 is described by Siemens for soft starts and a high switching frequency. The 3RW30 and 3RW40 cover sizes S00–S3, and the 3RW40 starts from S0. The range goes up to 106 A rated current (55 kW at 400 V). They are chosen when direct starting of the motor puts too much strain on the couplings or the network. |
| SIVACON S4 and S8plus panels | The SIVACON S4 reaches 4,000 A, and 6,300 A with the extended licence option, with design verification to IEC 61439, for industrial and commercial installations. The SIVACON S8plus is developed and tested to IEC 61439-2 and can have an active arc-fault protection system, with optical sensors, tested to IEC/TR 61641 and IEC TS 63107. The panel configuration is set on the basis of the single-line diagram and the component list. |
Why Siemens Electrical?
- 5SL3 (4.5 kA), 5SL6 (6 kA) and 5SL4 (10 kA) circuit breakers to IEC/EN 60898-1, one module wide per pole
- 3RT2 contactors and 3RV2 motor protection circuit breakers on the same four sizes, S00–S3
- 3RW30 and 3RW40 soft starters in sizes S00–S3, up to 106 A
- Communicating 5SL6 COM variants, with energy and status data
- SIVACON S4 panels up to 4,000 A, with design verification to IEC 61439
- Circuit protection, motor control and the distribution board from the same product family
Which Siemens Electrical codes and series are requested most often?
| Code | Description |
|---|---|
| 5SL3 | Modular circuit breaker, 4.5 kA, B and C characteristics |
| 5SL6 | Modular circuit breaker, 6 kA, 0.3–63 A, B and C characteristics |
| 5SL4 | Modular circuit breaker, 10 kA, B, C and D characteristics |
| 5SL6 COM | Communicating circuit breaker, with energy and status data |
| 5SY | Modular circuit breaker for industrial applications, up to 25 kA |
| 3RT2 | SIRIUS contactor, sizes S00, S0, S2 and S3 |
| 3RT1 | SIRIUS contactor for large sizes (S6, S10) |
| 3RV2 | Motor protection circuit breaker, sizes S00–S3 |
| 3RV29 | Infeed system for 3RV2 circuit breakers |
| 3RU2 | SIRIUS overload relay |
| 3RW30 | Soft starter for soft starts and a high switching frequency |
| 3RW40 | Soft starter with current limiting and integrated overload relay |
Where is Siemens Electrical equipment used?
- Residential electrical installations – meter panels and small distribution boards
- Commercial buildings – offices, shops, hotels
- Industry – circuit protection and motor control for pumps, fans and compressors
- Main low-voltage distribution boards for industrial and commercial installations
- Pumping and water treatment stations
How do we supply Siemens Electrical in Romania?
At InfiniTrade we supply Siemens electrical equipment - 5SL circuit breakers, SIRIUS contactors, 3RV2 circuit breakers, soft starters and components for SIVACON panels - to installers in Romania to order. We work from the manufacturer's technical documentation; the exact availability is stated in the quotation. As a general rule, standard ready-prepared devices can ship in 24–72 h when the item is in stock, locally or at the supplier, while specially ordered configurations typically take 1–4 weeks. For a correct quotation send us the full device code, or the rated current, the characteristic (B, C or D) and the single-line diagram, and each order receives a separate quotation.
Our offer covers the switchgear and the panels; availability for each SIVACON series is checked on request, and the software configuration of the monitoring system is agreed separately.
Frequently asked questions about Siemens Electrical
How do I read a Siemens 5SL circuit breaker code, for example 5SL4102-8?
5SL4 is the series (10 kA); the first digit after the series shows the number of poles (1 = 1P, 2 = 2P, 3 = 3P, 5 = 1P+N), the next two digits give the rated current (02 = 2 A; for fractional currents the code differs, for example 14 = 0.3 A), and the suffix after the hyphen gives the characteristic: -6 = B, -7 = C, -8 = D. So 5SL4102-8 is a single-pole 2 A circuit breaker with the D characteristic.
Can I order accessories for an already installed 3RT2 contactor or 3RV2 circuit breaker?
Yes, but the accessories depend on the size. For example, the 1NO+1NC auxiliary contact block is mounted transversely (3RV2901-1E) or laterally (3RV2901-1A) on sizes S00, S0 and S3, while the three-phase feed-in terminal has a different code at S00/S0 (3RV2925-5AB) and at S2 (3RV2935-5A). Send the full code of the base device, and we will determine the accessory.
What data do you need to propose a Siemens contactor for a motor?
The rated power or current of the motor, the mains voltage, the control coil voltage (for example 24 V AC/DC, 110 V AC or 230 V AC), the number of auxiliary contacts required and the type of starting (direct, star-delta, reversing). If you already have a device installed, the code on the label saves us these questions.
How long does it take to bring in Siemens components for a panel?
To order, typically 1–4 weeks, depending on the series and the configuration; the exact lead time is confirmed in the quotation. SIVACON panels are quoted on the basis of the single-line diagram and the component list.
How do I request a Siemens Electrical quotation?
Send the Siemens Electrical code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Siemens, Siemens AG (manufacturer documentation)