Smar supplier in Romania
For Smar we quote LD290, LD300 and LD400 pressure transmitters, TT300 temperature transmitters, FY300 positioners, CD600Plus controllers and the DFI302 platform; we need the series, the protocol (HART, FOUNDATION Fieldbus, PROFIBUS PA) and the measuring range.
Who is Smar and what does it make?
Smar is a Brazilian manufacturer of process instrumentation and automation. The programme starts from field transmitters: absolute, differential, gauge, hydrostatic and level pressure, temperature, density and position, in versions with a 4–20 mA signal, HART, FOUNDATION Fieldbus or PROFIBUS PA. To these are added smart positioners for valves, pneumatic and electric actuators and a communications line with HART and PROFIBUS PA interfaces, junction boxes, repeaters and surge protectors.
On the control side, Smar builds the CD600Plus multi-loop digital controller, the DFI302 platform with input and output modules, the LC800 programmable controller and the AuditFlow flow measurement system, with a flow computer. The ProcessView64 supervisory software and the NOVA O-PAS line of distributed systems, built on the Open Process Automation standard, complete the programme.
A Smar transmitter or controller on an existing machine is identified by the series and the code on the nameplate, and the communication protocol decides which version can be fitted in its place. The same series appears in several fieldbus versions, so the series alone is not enough for a quotation. The LD, TT and TP series each have a version for every protocol: 4–20 mA with HART, FOUNDATION Fieldbus and PROFIBUS PA, to which are added the wireless WirelessHART versions of the 400 series. For a correct choice, we check the existing fieldbus of the installation, the measuring range and the type of process connection. For a quotation, send the complete series, the measuring range and the type of output.
What do we supply from the Smar range?
| Product | Description |
|---|---|
| LD290, LD300 and LD400 pressure transmitters | LD290 to LD293 are in-line gauge pressure transmitters, and LD301, LD302 and LD303 of the LD300 series cover the HART, FOUNDATION Fieldbus and PROFIBUS PA protocols. The LD400 series comes in HART and WirelessHART versions, for pressure, level and flow. |
| TT300 and TT400 temperature transmitters | TT301, TT302 and TT303 are transmitters for HART, FOUNDATION Fieldbus and PROFIBUS PA, while TT383 measures on eight channels. TT400SIS is for safety instrumented systems (SIS), and TT400WH and TT481WH work through WirelessHART. |
| FY300, FY400 and FY500 smart positioners | Positioners for control valves. The BFY brackets allow mounting on valves of several makes. The programme also includes ACP301 and ACP303 pneumatic actuators and electric actuators of the AD, AR and AL series. |
| CD600Plus, DFI302 and LC800 controllers | CD600Plus is a multi-loop digital controller, configured with the CONF600 Plus application. DFI302 is a control platform with controllers and input and output modules, and LC800 is a programmable controller with a CPU800 processor and the LogicView programming environment. |
Why Smar?
- The same series of transmitters appears in 4–20 mA, HART, FOUNDATION Fieldbus and PROFIBUS PA versions — the version is chosen according to the fieldbus of the installation
- Pressure, temperature, density and position transmitters from the same family — the instruments of a loop are chosen from the same programme
- WirelessHART versions for pressure, temperature and position — they suit points that are hard to cable
- CD600Plus, DFI302 and LC800 controllers — the control loop can be covered from measurement to command
- FY300, FY400 and FY500 positioners with BFY brackets for several makes of valves — they are mounted on existing valves after the bracket is checked
Which Smar codes and series are requested most often?
| Code | Description |
|---|---|
| LD290 | In-line gauge pressure transmitter, 4–20 mA |
| LD291 | In-line pressure transmitter, 4–20 mA with HART |
| LD292 | In-line pressure transmitter, FOUNDATION Fieldbus |
| LD301 | HART pressure transmitter |
| LD303 | PROFIBUS PA pressure transmitter |
| LD400 | HART pressure transmitter |
| TT301 | 4–20 mA temperature transmitter with HART |
| TT383 | PROFIBUS temperature transmitter, eight channels |
| FY301 | Smart positioner for valves |
| CD600Plus | Multi-loop digital controller |
| DFI302 | Control and automation platform |
| LC800 | Programmable controller, 800 series |
Where is Smar equipment used?
- Pressure loops — LD290, LD300 and LD400 transmitters on pipes and vessels
- Level and flow measurement — hydrostatic and in-line versions and RD500 radar
- Valve control — FY positioners and pneumatic or electric actuators
- Temperature measurement — TT300 transmitters with multiple channels
- Process control — DFI302 platforms and multi-loop controllers
How do we supply Smar in Romania?
We can quote Smar pressure, temperature, density and position transmitters, valve positioners and controllers from the CD600Plus, DFI302 and LC800 series. For a correct quotation we need the complete series from the nameplate, the measuring range, the communication protocol and, for positioners, the type of actuator and the mounting bracket. If you are replacing an existing instrument, send a photo of the nameplate and a description of the loop. Items are supplied to order, usually in 1–4 weeks; for special versions or systems with several modules the lead time may be longer. The exact lead time appears in the quotation.
The configuration of an existing instrument, with its protocol and loop parameters, is checked once we receive the nameplate and the complete series, and compatibility is established in the quotation.
Frequently asked questions about Smar
What roles do LD290, LD300, LD400, TT300, FY300 and CD600Plus have at Smar?
LD290, LD300 and LD400 are pressure transmitters, TT300 is the temperature series, FY300 is for positioners, and CD600Plus is for multi-loop control.
How do I choose between LD301, LD302 and LD303?
The three transmitters of the LD300 series differ by protocol: LD301 uses HART, LD302 FOUNDATION Fieldbus and LD303 PROFIBUS PA. The choice follows the fieldbus of the installation, then the measuring range and the type of connection. Send the series from the nameplate of the current instrument and we confirm the suitable version in the quotation.
Do you supply Smar instruments in Romania, and how fast?
Instruments are supplied to order, usually in 1–4 weeks, and can ship in 24–72 h when the item is in stock, locally or at the supplier. For special versions or systems with several modules, the lead time may be longer; the exact lead time is confirmed in the quotation.
Can I replace a Smar CD600 controller with a CD600Plus?
Yes, if the type of inputs and outputs, the functions used and the loop configuration match; compatibility between generations is checked against these data. CD600Plus is the multi-loop digital controller of the current programme, configured with CONF600 Plus. Send the nameplate of the existing controller and a description of the loop, and we check compatibility before the quotation.
What data do I send for an LD301 or LD303 transmitter?
Send the complete series from the nameplate, the measuring range, the type of output or protocol (4–20 mA, HART, FOUNDATION Fieldbus, PROFIBUS PA), the type of process connection and, if applicable, the requirement for hazardous areas. For positioners add the actuator and the mounting bracket.
How do I request a Smar quotation?
Send the Smar code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Nova Smar S/A (manufacturer documentation)