Teledyne Gas and Flame Detection supplier in Romania
Gas and flame detection systems for industrial installations
Who is Teledyne Gas and Flame Detection and what does it make?
Teledyne Gas and Flame Detection is an American manufacturer of toxic gas, combustible gas and flame detection equipment, with over a hundred years of combined experience in industrial safety. The range covers OLCT and OLC fixed detectors, MX series multi-channel controllers, GasSurveyor portable detectors and SpyGlass and DF-TV7 flame detectors. In Romania, the brand means access to detection equipment used where a gas leak or the start of a fire must be signalled within seconds.
Teledyne Gas and Flame Detection covers several sensor technologies under the same brand: electrochemical and catalytic on the OLCT family, infrared on the GD10-IR series and on the IR3 triple-sensor flame detectors. The MX controllers centralise the fixed detectors from a single operator station, from the compact single-channel unit (MX 16) to multi-channel models (MX 62, MX 256); the number of channels is confirmed per model.
For installations in Romania with a risk of explosion or poisoning — refineries, LPG stations, chemical depots, ships — the range includes detectors with ATEX variants according to the manufacturer's documentation (to be confirmed per model), useful for extensions or for replacing existing detectors. Compatibility with an existing controller is checked case by case.
What do we supply from the Teledyne Gas and Flame Detection range?
| Product | Description |
|---|---|
| OLCT Family — Fixed Gas Detectors | Fixed toxic and combustible gas detectors, with electrochemical and catalytic variants (OLCT-10, OLCT-20, OLCT-60, OLCT-80, OLCT-100). Mounted near tanks, compressors or process lines, they send the signal to a central controller. The choice of model depends on the gas type, the concentration range and the certification zone of the installation; these details must be confirmed before quoting. |
| MX Series Controllers | Central controllers for networks of fixed detectors, from the single-channel MX-16 unit to multi-channel models (MX-32, MX-43, MX-62, MX-256); the number of channels is confirmed per model. They manage alarm thresholds and can control relays for ventilation or emergency shutdown. Integration with an existing SCADA system depends on the communication protocol available on the chosen variant. |
| GasSurveyor Family and SpyGlass Flame Detectors | Portable multi-gas detectors from the GasSurveyor 500 series, with self-test functions, complemented by leak detectors (LeakSurveyor) and marine variants (ShipSurveyor-IR). The SpyGlass SG50 and DF-TV7 optical flame detectors use a UV/IR or triple infrared sensor, for areas with a fire risk at a distance from the source. Battery life and coverage angle must be confirmed for each model. |
Why Teledyne Gas and Flame Detection?
- Covers toxic gas, combustible gas and flame under the same brand, useful for installations that prefer a single supplier
- MX controllers centralise the fixed detectors from a single operator station; the number of channels depends on the model
- SpyGlass SG50 flame detectors are available in IR3 (triple infrared) and UV/IR variants
- Some fixed detectors (for example OLCT 80) have ATEX variants according to the manufacturer's technical documentation, relevant for explosion-risk zones; certification is confirmed per model
Which Teledyne Gas and Flame Detection codes and series are requested most often?
| Code | Description |
|---|---|
| OLCT-10 | Fixed toxic and combustible gas detector, OLCT family |
| OLCT-20 | Fixed toxic or combustible gas detector, OLCT family |
| OLCT-60 | Fixed industrial gas detector, OLCT family |
| OLCT-80 | Fixed gas detector, OLCT family (a wireless OLCT 80W variant also exists) |
| OLCT-100 | Fixed toxic and combustible gas detector, OLCT family |
| GD10-IR | Infrared combustible gas detector, fixed mounting |
| GD1 | Open-path gas detector |
| Model 100 | Fixed transmitter for toxic gases |
| Model 1000 | Gas analyser, fixed mounting |
| Meridian | Universal gas detector, fixed mounting |
| Microsafe 500 | Fixed gas detector, Microsafe family |
| Microsafe 600 | Fixed gas detector, extended Microsafe family |
| MX-16 | Compact central controller, 1 channel |
| MX-32 | Multi-channel central controller, analogue and digital |
| MX-43 | Multi-channel central controller |
| MX-62 | Multi-channel central controller, up to 16 channels |
| MX-256 | Central controller for extended detector networks |
| Surveyor 4B | Single-channel gas controller |
| iTrans2 | Fixed-mount gas transmitter |
| GasSurveyor 500 | Portable multi-gas detector, GasSurveyor family |
| LeakSurveyor | Portable gas leak detector |
| ShipSurveyor-IR | Portable detector with infrared sensor, marine applications |
| SpyGlass SG50 | Optical flame detector, UV/IR sensor |
| DF-TV7 | Optical flame detector with infrared sensor |
| Multiflame 40 | Optical flame detector, Multiflame family |
Where is Teledyne Gas and Flame Detection equipment used?
- Oil and gas — detection at wells, refineries and storage terminals
- Marine — certified detectors for ships and offshore platforms
- Chemicals and petrochemicals — monitoring of toxic and combustible gases
- LPG storage — leak and flame detection at tanks
How do we supply Teledyne Gas and Flame Detection in Romania?
We work with the Teledyne Gas and Flame Detection range, starting from the OLCT, MX and GasSurveyor series, based on information from the manufacturer's technical documentation — for requests that go beyond this documentation, the quotation states what is confirmed. We bring in the equipment to order, usually in 1–4 weeks; availability is checked in the quotation. For a quotation, we need the exact code of the detector, the certification zone of the installation and the communication protocol used.
The models available on the Romanian market are checked on each request; warranty service stays with the manufacturer's network, and we supply the equipment.
Frequently asked questions about Teledyne Gas and Flame Detection
What product range does Teledyne Gas and Flame Detection have?
Teledyne Gas and Flame Detection makes fixed and portable toxic or combustible gas detectors, MX series central controllers and optical flame detectors from the SpyGlass and DF-TV7 families, according to the manufacturer's technical documentation.
How do I choose a detector from the OLCT family?
The choice depends on the gas to be detected, the concentration range of interest and the certification zone of the installation (ATEX or IECEx); send us these details, plus the exact code if you know it, so that we can identify the suitable variant from the OLCT family.
Why choose Teledyne Gas and Flame Detection for a gas detection project?
Because it covers toxic gas, combustible gas and flame under the same brand, with ATEX variants from the manufacturer's documentation on certain models (to be confirmed per code), which simplifies integration and maintenance compared with combining different manufacturers for each type of risk.
Which MX controller should I choose for an installation with many detection points?
The MX series ranges from single-channel controllers (MX-16) to multi-channel models (MX-62, MX-256); the number of detectors to be centralised and the distance between them decide the suitable variant, and these details must be confirmed before the quotation.
What details do you need for a quotation on Teledyne detectors?
Send the exact code of the desired model or, if you do not know it, the gas type or fire risk to be covered, the certification zone of the installation and the number of detection points needed.
How do I request a Teledyne Gas and Flame Detection quotation?
Send the Teledyne Gas and Flame Detection code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Teledyne Gas and Flame Detection (manufacturer documentation)