Tecfluid supplier in Romania
For Tecfluid we quote FLOMID and FLOMAT electromagnetic flow meters, TM series turbine flow meters, COVOL oscillating piston flow meters, PS plastic-tube rotameters and LP level indicators.
Headquarters: Sant Just Desvern, Spain
Who is Tecfluid and what does it make?
Tecfluid is a Spanish manufacturer of flow meters and level measuring instruments, based in Sant Just Desvern, in the province of Barcelona. The range covers variable-area flow meters (rotameters), electromagnetic, turbine, oscillating piston and ultrasonic flow meters, as well as level indicators. They are used for measuring, dosing and totalising liquids in process plants.
The electromagnetic flow meters are the FLOMID and FLOMAT series. FLOMID, modular, in compact or remote version, measures conductive liquids above 20 µS/cm, between 10 l/h and 7,000 m³/h, in diameters from DN3 to DN500, with a 316L stainless steel body and liners of PP, PVDF, ebonite or PTFE. FLOMAT is an insertion flow meter for large-diameter pipes, from DN40 to DN2000. Both have 4–20 mA and 0–1000 Hz outputs, a totaliser and empty-pipe detection.
The TM series, with a turbine, measures clean liquids of low viscosity, between 300 l/h and 1100 m³/h. The COVOL series, with an oscillating piston, reaches viscosities of up to 120,000 cP. The LP series is a level indicator with a float made of PP, PVC or PVDF, with a measuring length between 0.3 and 6 m. The PS series is a plastic-tube rotameter, with scales calibrated in l/h, l/min or percent. FLOMAT electrodes can be made of Hastelloy C, 316L, zirconium, titanium or tantalum. For a quotation, what matters is the series, the nominal diameter, the liquid and the output signal.
What do we supply from the Tecfluid range?
| Product | Description |
|---|---|
| FLOMID electromagnetic flow meters | Modular flow meters, compact or remote, for conductive liquids above 20 µS/cm, from 10 l/h to 7,000 m³/h, DN3–DN500. They are offered with DIN or ANSI flanges, in between-flanges or sanitary design, with an accuracy of ±0.5 %. |
| FLOMAT flow meters | Electromagnetic insertion flow meters, for large-diameter pipes, DN40–DN2000, with flow between 2 and 113,000 m³/h. The body is made of 316L or PVDF, and the accuracy is ±3.5 % of the reading. |
| TM turbine flow meters | For clean liquids of low viscosity, from 300 l/h to 1100 m³/h, with an accuracy of ±0.5 %. Connections with DIN or ANSI flanges, BSP or NPT thread or DIN 11851 sanitary; output with pick-up coil, 4–20 mA, HART or Modbus. |
| COVOL, PS and LP indicators | COVOL, with an oscillating piston, works between 10 l/h and 60 m³/h, DN10–DN100, with an accuracy of ±0.8 %. The PS series is a compact plastic-tube rotameter. LP is a level indicator with a 4–20 mA output, in lengths between 0.3 and 6 m. |
Why Tecfluid?
- Electromagnetic flow meters without moving parts — the reading does not depend on the density or viscosity of the liquid
- FLOMAT with insertion for DN40–DN2000 — intended for large-diameter pipes
- COVOL for viscous liquids — oscillating piston, up to 120,000 cP, from 10 l/h to 60 m³/h
- TM turbines with 316L stainless steel body — for clean liquids, with an AISI 430 rotor
- 4–20 mA, HART and Modbus outputs on several series — integration into the control system is direct, on a standard signal
Which Tecfluid codes and series are requested most often?
| Code | Description |
|---|---|
| FLOMID | Modular electromagnetic flow meter, DN3–DN500 |
| FLOMID-2FX | FLOMID flow meter with DIN or ANSI flanges |
| FLOMID-0FX | FLOMID flow meter, between flanges |
| FLOMAT | Electromagnetic insertion flow meter, DN40–DN2000 |
| TM | Turbine flow meter, 300 l/h – 1100 m³/h |
| COVOL | Oscillating piston flow meter, DN10–DN100 |
| PS | Plastic-tube rotameter |
| LP | Float level indicator, 0.3–6 m |
| LT | Magnetic transmission level indicator |
| CU | Ultrasonic flow meter |
Where is Tecfluid equipment used?
- Chemical industry — electromagnetic flow meters with PTFE and PVDF liners
- Food industry — DIN 11851 sanitary connections, for food liquids, oil and honey
- Petrochemicals — TM turbines for petrochemical products and LP level indicators
- Paints, resins and inks — totalising with the COVOL oscillating piston
- Dosing and filling — volume totalising with COVOL when filling tanks
How do we supply Tecfluid in Romania?
We can quote Tecfluid electromagnetic flow meters (FLOMID and FLOMAT), turbine (TM), oscillating piston (COVOL) and rotameters, as well as level indicators and parts for existing installations. For a correct quotation, send the series, the nominal diameter, the liquid and its conductivity or viscosity, the flow range, the working pressure and temperature, the connection and the output signal required. The order is fulfilled; the usual lead time is 1–4 weeks, and depending on the specification it may be longer. The exact date appears in the quotation.
The field of use of each flow meter is confirmed in the quotation, according to the liquid, conductivity and viscosity.
Frequently asked questions about Tecfluid
What are FLOMID, FLOMAT, TM and COVOL in the Tecfluid range?
Tecfluid makes FLOMID and FLOMAT electromagnetic flow meters, TM turbine, COVOL oscillating piston, PS rotameters, CU ultrasonic flow meters and LP and LT level indicators. The company is based in Sant Just Desvern, Spain.
How do I choose between FLOMID, TM and COVOL?
FLOMID measures conductive liquids, above 20 µS/cm, without moving parts. TM suits clean liquids of low viscosity, and COVOL viscous liquids, up to 120,000 cP. Send the liquid, the conductivity or viscosity and the flow range, and we check the series.
Do you supply Tecfluid in Romania, and how quickly?
Yes, the flow meters are supplied to order, usually in 1–4 weeks. An item can ship in 24–72 h when the item is in stock, locally or at the supplier. We confirm the exact date for your code in the quotation.
Can I replace an old flow meter with a Tecfluid one?
It is possible if the nominal diameter, the flanges, the liquid and the output signal are compatible. The FLOMID and TM series have DIN and ANSI connections, and a 4–20 mA, HART or Modbus output. Send the code of the current flow meter and the process data, and we check the suitable series.
What do I need to specify for a FLOMID electromagnetic flow meter?
FLOMID is a modular electromagnetic flow meter. Send the nominal diameter (DN), the liquid and its conductivity, the flow range, the pressure and temperature, the liner material required (PP, PVDF, ebonite or PTFE), the type of electrodes and the compact or remote version. Add the output signal and the power supply required.
How do I request a Tecfluid quotation?
Send the Tecfluid code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Tecfluid S.A. (manufacturer documentation)