TERAL supplier in Romania

For TERAL we quote booster sets from the NX-VFC and SVMV series, drainage pumps from the APL, ACS, ABO and KO series, coolant pumps and oil pumps GPL2, GPM2, TRP; we need the series and the parameters.

Founded in 1918 · Headquarters: Fukuyama, Japan

Request a quote

Who is TERAL and what does it make?

TERAL is a Japanese company from Fukuyama, in Hiroshima Prefecture, active since 1918, which makes pumps, fans and equipment for water supply and water treatment. The pump range includes water supply sets, firefighting pumps, circulation pumps, drainage pumps, oil pumps and coolant pumps for machine tools.

The water supply sets are built around a suction tank. The NX-VFC series maintains constant pressure at the end of the network through frequency control, with automatic alternating operation of the pumps; the multiple control version works with rotation across 3–5 pumps, and the SVMV series across 2–6 pumps. Drainage pumps are submersible and cover wastewater and effluent, in cast iron, stainless steel or resin versions, including with a cutter in the KO and AGO series.

Coolant pumps are divided into immersed, seal-less types, from the VKP, LFE, LHW, LPW and other series, and self-priming floor-mounted types, VKN, LPS and LPSE. Oil pumps include the GPL2 gear pumps, for low head, and GPM2, for high head, as well as the TRP and TRP-M internal gear pumps. For a quotation, send the series, the flow, the head and the fluid.

What do we supply from the TERAL range?

ProductDescription
Water supply sets NX-VFC and SVMVBooster sets with a suction tank, with frequency control for constant pressure at the end of the network. NX-VFC has automatic alternating operation, and the multiple control version rotates 3–5 pumps; the SVMV series rotates 2–6 pumps.
Submersible drainage pumpsThe APL, ASU, ACS, ADS, ADM, AAX, ACU, ABO, SVC, APV, AVC, SCU and SUMP series discharge wastewater and effluent. The KO and AGO series have a cutter for water with solids, and the material varies between cast iron, stainless steel and resin.
Coolant pumpsThe immersed, seal-less types are single-stage (VKP, LFE, LFO) or multistage (LHW, LBM, LBK, LPW, LVS). The self-priming floor-mounted types are VKN, LPS and LPSE, and SKM is used for cleaning coolant tanks.
Oil pumps GPL2, GPM2, TRP and TRP-MGPL2 is a gear pump with direct coupling, for low head, and GPM2 for high head. TRP is an internal gear pump supplied without a motor, and TRP-M is the direct drive version.

Why TERAL?

  • NX-VFC sets with frequency control — they maintain constant pressure at the end of the network, with the pumps alternating automatically
  • Rotation across 3–5 pumps on NX-VFC with multiple control and across 2–6 pumps on SVMV — installations with several pumps distribute the wear between units
  • Drainage pumps in cast iron, stainless steel or resin — the material is chosen by the fluid discharged
  • Immersed or floor-mounted coolant pumps — they are matched by the type of tank on the machine tool
  • Oil pumps with external or internal gears — they are chosen by the head and the type of coupling

Which TERAL codes and series are requested most often?

CodeDescription
NX-VFCConstant pressure water supply set, frequency control
SVMVWater supply set with rotation across 2–6 pumps
APLSubmersible drainage pump in cast iron
ACSSubmersible drainage pump in stainless steel, wastewater
KOSubmersible drainage pump with cutter, in cast iron
AGOSubmersible drainage pump with cutter, in cast iron
VKPImmersed coolant pump, single-stage, seal-less
LHWImmersed multistage coolant pump
LPSSelf-priming floor-mounted coolant pump
GPL2Gear oil pump, low head, direct coupling
GPM2Gear oil pump, high head, direct coupling
TRPInternal gear oil pump, without motor

Where is TERAL equipment used?

  • Water supply — constant pressure in networks with several pumps
  • Machine tools — coolant circulation in immersed or floor-mounted tanks
  • Oil transfer — pumps with external or internal gears
  • Industrial drainage — discharge of wastewater and effluent
  • Fire protection — firefighting pumps

How do we supply TERAL in Romania?

We can quote TERAL pumps from the water supply, drainage, coolant and oil series, depending on the series and the process data. For a correct quotation, send the series or the code from the nameplate, the flow, the head, the fluid and the temperature, plus the motor voltage and frequency. We supply pumps to order, usually in 1–4 weeks; for special items the lead time can be longer and is set in the quotation.

We check in the quotation whether the requested series exists in the voltage and frequency version that you need.

Frequently asked questions about TERAL

What are the NX-VFC and SVMV sets, the drainage pumps and the oil pumps at TERAL?

TERAL is a Japanese company from Fukuyama, active since 1918, which makes pumps, fans and equipment for water supply. The pump range includes the NX-VFC and SVMV sets, drainage pumps, coolant pumps, oil pumps and firefighting pumps.

How do I choose between NX-VFC and SVMV?

NX-VFC keeps constant pressure at the end of the network through frequency control and alternates the pumps automatically; the multiple control version rotates 3–5 pumps. SVMV rotates 2–6 pumps. Send the total flow, the pressure at the end of the network and the number of pumps wanted, and we check the suitable series.

Do you supply TERAL in Romania, and how fast?

Yes. TERAL pumps arrive to order, usually in 1–4 weeks. An item can ship in 24–72 h when the item is in stock, locally or at the supplier. For your series, the date is set in the quotation.

How do I find a coolant pump for a machine tool?

The first choice is the type of mounting: immersed in the tank (VKP, LFE, LHW, LPW) or floor-mounted self-priming (VKN, LPS, LPSE). Send the current series from the nameplate, the depth of the tank, the flow and the head, and we then check whether a compatible item exists.

What data do you ask for a quotation for a GPL2 or TRP oil pump?

For GPL2, GPM2, TRP or TRP-M, send the series from the nameplate, the flow, the head, the viscosity of the oil, the type of coupling and the motor data. For TRP, state whether you need the pump alone or the TRP-M version, with direct drive.

How do I request a TERAL quotation?

Send the TERAL code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: TERAL Inc. (manufacturer documentation)