Who is Vanguard Instruments and what does it make?

Vanguard Instruments is an American manufacturer of diagnostic instruments for substation equipment, based in Ontario, California. The range covers transformer testing (turns ratio, winding resistance, excitation current), circuit breaker testing and protection relay testing. We can quote from the Vanguard range the instruments commonly used by high-voltage equipment testing laboratories in Romania.

The portfolio is structured by the type of equipment tested: transformer turns ratio testers (TTR) from the TRF and ATRT series, micro-ohmmeters for winding resistance from the TRM and Auto-Ohm series, current transformer testers from the EZCT series, and instruments dedicated to circuit breaker testing — timing analysers such as DigiTMR S2, and vacuum circuit breaker testers such as VBT-75 S2. For protection there is a primary current injector, PCI-600, used to check the operation of relays and protection circuits.

In PRAM laboratories (protection, relays, automation, metering) and in substation maintenance, the Vanguard range covers the testing of transformers, circuit breakers and protection circuits; the manufacturer holds certifications and offers laboratory calibration services with accreditations, according to the manufacturer's documentation.

What do we supply from the Vanguard Instruments range?

ProductDescription
Transformer Turns Ratio Testers, TRF/ATRT SeriesInstruments for measuring the turns ratio (TTR) of power and distribution transformers, used for acceptance and periodic checks of transformers in substations. The ATRT series includes automated versions for fast testing of several tap positions of the transformer.
Micro-ohmmeters, TRM and Auto-Ohm SeriesInstruments for measuring the winding resistance of transformers and the contact resistance of circuit breakers, with test currents configurable according to the size of the equipment tested. Used for early detection of connection or winding problems.
Current Transformer Testers, EZCT SeriesInstruments for testing current transformers (CT) in substations, checking the turns ratio and core saturation. Used for acceptance and periodic diagnostics of measurement and protection circuits based on current transformers.
Circuit Breaker Timing Analyser DigiTMR S2Analyser for measuring the opening and closing times of high-voltage circuit breakers, an essential parameter for checking the correct operation of the operating mechanism. Used together with contact resistance testers in the periodic maintenance of circuit breakers.

Why Vanguard Instruments?

  • Range for substation diagnostics — transformers, circuit breakers, protection relays
  • TTR transformer turns ratio testers — TRF and ATRT series for checking transformers
  • Dedicated micro-ohmmeters — TRM and Auto-Ohm series for winding and contact resistance
  • Manufacturer with certifications and laboratory calibration services, according to the manufacturer's documentation

Which Vanguard Instruments codes and series are requested most often?

CodeDescription
TRF-250transformer turns ratio tester (TTR)
TRF-250 Aautomated transformer turns ratio tester
TRF-100transformer turns ratio tester (TTR)
ATRT-01 S3automatic transformer turns ratio tester
ATRT-01B S3automatic transformer turns ratio tester
ATRT-03 S2automatic transformer turns ratio tester, 3-phase
TRM-20winding resistance micro-ohmmeter
TRM-40winding resistance micro-ohmmeter
TRM-203winding resistance micro-ohmmeter
TRM-403winding resistance micro-ohmmeter
EZCT-2000Ccurrent transformer tester
EZCT-2KAcurrent transformer tester
CT-8000 S3circuit breaker test analyser
CT-7000 S3circuit breaker test analyser
DigiTMR S2circuit breaker timing analyser
CT-3500 S2circuit breaker test analyser
Auto-Ohm 200 S4contact resistance micro-ohmmeter
Auto-Ohm 10contact resistance micro-ohmmeter
VBT-75 S2vacuum circuit breaker tester
VBT-75P S2vacuum circuit breaker tester
MCCB-250moulded case circuit breaker tester
PCI-600primary current injector

Where is Vanguard Instruments equipment used?

  • Substations — testing of power transformers
  • Power distribution — maintenance and testing of circuit breakers
  • PRAM laboratories — periodic checks of high-voltage equipment
  • Relay protection — testing of protection circuits with a primary current injector

How do we supply Vanguard Instruments in Romania?

We supply Vanguard Instruments for testing transformers, circuit breakers and protection circuits, to order. Availability is confirmed for each order, usually in 1–4 weeks. For a quotation we need the code of the instrument (for example a tester from the TRF series or a micro-ohmmeter from the Auto-Ohm series), the test currents or voltages required and the type of equipment tested. Calibration certificates can be obtained on request, issued by the manufacturer or by an accredited laboratory.

Calibration is handled separately from the supply of equipment; availability and lead time for Vanguard models are checked individually on each order.

Frequently asked questions about Vanguard Instruments

What kind of instruments does Vanguard Instruments make?

Vanguard Instruments makes diagnostic instruments for substation equipment: transformer turns ratio testers, micro-ohmmeters, current transformer testers, circuit breaker analysers and primary current injectors for testing protection relays.

How do I choose a Vanguard Instruments tester for transformers?

The TRF or ATRT series are used for checking the turns ratio, the latter with automated versions for testing several tap positions. For winding resistance, the micro-ohmmeters from the TRM series are chosen. Send us the type and size of the transformer for the suitable recommendation.

Do you offer delivery in Romania for Vanguard Instruments?

We supply Vanguard Instruments to order, usually in 1–4 weeks from confirmation. Availability is checked individually for each model.

What data must I send for a Vanguard micro-ohmmeter quotation?

Send the code of the series wanted (for example TRM-203 or Auto-Ohm 200 S4), the test current required and the type of equipment tested — transformer or circuit breaker — so that we can check availability and prepare the quotation.