Vitrek supplier in Romania
Hipot testers, power analysers and data acquisition systems
Headquarters: Lockport, Illinois, USA
Who is Vitrek and what does it make?
Vitrek is an American manufacturer of precision electrical test instruments, based in Lockport, Illinois. Under the same roof also operate the GaGe brand, for high-speed digitisers and data acquisition, and MTI Instruments, for rotor balancing systems and non-contact displacement sensors. From this range we can quote the hipot testers, power analysers and teraohmmeters frequently requested in electrical safety laboratories in Romania.
What sets the Vitrek family of hipot testers apart is the wide voltage coverage: the V10X series reaches 10 kV AC or 15 kV DC, with a leakage current resolution of 100 pA, while the 95X series delivers up to 200 mA of test current at 6-30 kV AC/DC. The power analysers of the PA900/PA910/PA920 family reach accuracy of up to 0.024% and a 5 MHz bandwidth, for measurements on waveforms with a high crest factor. The 4700 series for high voltage measures directly up to 10 kV DC/AC, extendable to 150 kV with smartprobe probes.
For the Romanian market, Vitrek makes sense for electrical safety testing laboratories, for electronics and automotive production lines that need hipot/insulation resistance tests in series, and for rotor balancing applications in turbomachinery.
What do we supply from the Vitrek range?
| Product | Description |
|---|---|
| V10X Series — Hipot Testers | AC/DC hipot testers with a test voltage of up to 10 kV AC or 15 kV DC, optionally extendable to 30 kV AC, a leakage current resolution of 100 pA and a ground bond continuity test of up to 40 A. Used for checking the dielectric strength of electrical equipment before commissioning. |
| PA900/PA910/PA920 Series — Power Analysers | Precision power analysers with accuracy of up to 0.024% on the PA920 channel, a 5 MHz measurement bandwidth and a rate of up to 100 complete readings per second. The PA900 tolerates crest factors of up to 30:1, useful with non-linear loads. Typical application: characterising the efficiency of converters and power supplies. |
| 4700 Series — High Voltage Measurement | High voltage measurement system, with direct reading of up to 10 kV DC or AC rms and extension to 150 kV through dedicated smartprobe probes. Used for checking and calibrating other high-voltage equipment or for laboratory measurements where the precision of the reference source matters. |
| MTI PBS eXpress / PBS-4100+ — Rotor Balancing | Dynamic rotor balancing systems, used in particular in the aviation industry for rotating components of turbine engines. They combine vibration measurement with non-contact displacement sensors from the Accumeasure family, for diagnosing imbalance without completely dismantling the assembly. |
Why Vitrek?
- Hipot testers with a test voltage of up to 15 kV DC and a leakage current resolution of 100 pA
- Power analysers with accuracy of up to 0.024% and a 5 MHz bandwidth for complex waveforms
- Separate MTI Instruments family for turbine engine rotor balancing
- ISO 9001:2015 and ISO 17025 certifications mentioned by the manufacturer
- High-voltage switching system (964i) for multi-point hipot testing on production lines
Which Vitrek codes and series are requested most often?
| Code | Description |
|---|---|
| 95X Series | AC/DC hipot tester, 6-30 kV, test current 200 mA |
| V7X Series | 5 kV hipot, insulation resistance up to 450 GΩ |
| V10X Series | AC/DC hipot 10-15 kV, 100 pA resolution |
| PA900 | power analyser, crest factor up to 30:1 |
| PA910 | power analyser, accuracy 0.045%, bandwidth 5 MHz |
| PA920 | power analyser, accuracy 0.024%, bandwidth 5 MHz |
| 4700 Series | high voltage measurement, 10 kV, extendable to 150 kV |
| 964i | multi-point high-voltage switching system |
| 98x Series | teraohmmeter, insulation testing up to 2.5 kV |
| DL Series | DC electronic load, configurable |
| PBS eXpress | rotor balancing system, MTI brand |
| PBS-4100+ | portable rotor balancing system, MTI brand |
| Accumeasure | non-contact capacitive displacement sensor |
Where is Vitrek equipment used?
- Aerospace and defence — rotor balancing, testing of critical components
- Automotive — hipot and insulation resistance testing on production lines
- Electronics — checking the electrical safety of finished equipment
- Semiconductors — teraohmmeters for measuring insulation resistance
- Electrical safety testing laboratories — power analysers and hipot testers
How do we supply Vitrek in Romania?
The data about Vitrek comes only from the manufacturer's technical documentation; the lead time and availability of the hipot range, the power analysers and the rotor balancing systems are given in the quotation. We supply Vitrek, GaGe and MTI Instruments instruments to order, usually in 1–4 weeks; we do not keep this range on the shelf. For a quotation we need the exact series of the instrument, the required test voltage or current and any accessories (probes, cables) required by the application. Configuration of the test automation software is the responsibility of the manufacturer or the line integrator.
QT Insite software is configured on existing production lines together with the customer's team, based on the line data.
Frequently asked questions about Vitrek
What products does Vitrek offer?
Vitrek makes hipot testers, precision power analysers and teraohmmeters, alongside high-speed digitisers under the GaGe brand and rotor balancing systems under the MTI Instruments brand, with its headquarters in Lockport, Illinois, USA.
How do I choose a Vitrek hipot tester by series?
Check the maximum test voltage required by the application: the V7X series covers up to 5 kV, the 95X series reaches 30 kV, and the V10X series offers fine leakage current resolution for high-quality insulation. The test current and the load type (resistive/capacitive) matter for the final choice.
How does the Vitrek range compare with other makes?
Vitrek covers hipot testing and power analysis for production lines and laboratories; in a comparison with other instruments, the practical difference appears in the accuracy of the power analysers and in the leakage current resolution of the hipot testers, where exact specifications are compared model by model.
Do you supply Vitrek products in Romania and how quickly?
Yes, to order; the lead time is usually 1–4 weeks, depending on the manufacturer's confirmation for the requested model and accessories.
What information do you need for a Vitrek quotation?
The exact series of the instrument (hipot, power analyser or rotor balancing), the required test voltage or current, the type of load to be tested and any additional accessories wanted, such as high-voltage probes or test cables.
How do I request a Vitrek quotation?
Send the Vitrek code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Vitrek (manufacturer documentation)