Wasson-ECE Instrumentation supplier in Romania
Process chromatographs and auto-samplers for gases
Founded in 1986 · Headquarters: Fort Collins, Colorado, USA
Who is Wasson-ECE Instrumentation and what does it make?
Wasson-ECE Instrumentation is an American company from Fort Collins, Colorado, active since 1986 and specialised in gas chromatography: from sampling and sample-introduction systems to process chromatographs and automation software. It started with the development of a gas auto-sampler and went on to build a process chromatograph. It also has a production facility in the Czech Republic, with full testing, opened in 2015.
The central product is the Eclipse process chromatograph, whose first system was sold in 2019: unlike classic analysers with packed columns and fixed temperature, it uses programmable micro-convection ovens and capillary columns, with up to four detectors (FID, TCD, PDHID), eight capillary columns and two programmable ovens. The simpler Pup takes a laboratory method with one column and one detector into the process. For installation in hazardous areas there are sample systems for unclassified areas, Class 1 Div 2 or ATEX zone 2. The small devices include the AS202 for unattended analysis of up to 12 gas cylinders, the LPG vaporiser for C3/C4 samples, the Dynamic Blender for multi-point calibration and the high-pressure natural gas sampling system with up to five sources.
This equipment is found in refinery and petrochemical laboratories, at natural gas analysis stations, at industrial gas production plants and, as spare parts, on analytical lines that are already installed.
What do we supply from the Wasson-ECE Instrumentation range?
| Product | Description |
|---|---|
| Eclipse (process chromatograph) | Process chromatograph with capillary columns and programmable micro-convection ovens, with up to four detectors. A version with a VUV detector (E-VUV) also exists. Used in the analysis of hydrocarbons and industrial gases and in chemical processes. |
| Pup | A lighter version of the Eclipse family, with one column and one detector, with a programmable or isothermal oven. It takes an existing laboratory method into the process. |
| Process sample systems | Automatic conditioning systems for liquid or gas samples, built for non-hazardous areas or for areas with explosion risk, according to the manufacturer's documentation, for direct connection to Eclipse, Pup or Neutrino. |
| Small devices (AS202, LS100B, Vaporizer, Dynamic Blender) | Gas auto-sampler with an oven of up to 135 °C, auto-sampler for pressurised liquids, LPG vaporiser for GC and dynamic blender for multi-point calibration with a single standard. |
Why Wasson-ECE Instrumentation?
- Eclipse process chromatograph with capillary columns — laboratory-grade quality in the process, with up to four detectors and eight columns in a single instrument
- Pup for simple methods — one column and one detector, moved from the laboratory to the process line
- Sample systems made for Ex areas — ATEX zone 2 IIC T1–T4 and Class 1 Div 2 A, B, C, D
- High-pressure natural gas sampling system — up to five sources to the chromatograph, with controlled heating and pressure
- Production and testing in the Czech Republic — a facility with full manufacturing, in addition to the one in Colorado
Which Wasson-ECE Instrumentation codes and series are requested most often?
| Code | Description |
|---|---|
| Eclipse | Process chromatograph with capillary columns and micro-ovens |
| E-VUV | Eclipse with VUV detector |
| Pup | Process chromatograph with one column and one detector |
| AS202 | Gas auto-sampler, 12 cylinders of 500 mL or 9 of 1 L |
| LS100B | Auto-sampler for pressurised liquids (LPG) |
| Dynamic Blender | Dynamic blender for multi-point calibration |
| Hermes | Automation platform for analysers |
Where is Wasson-ECE Instrumentation equipment used?
- Refineries and petrochemicals — process and laboratory analysis of hydrocarbons
- Natural gas — high-pressure sampling and composition analysis
- LPG and NGL — vaporisation and C3/C4 analysis
- Industrial gases and chemicals — impurity monitoring
- Industrial and environmental laboratories — reconfigured chromatographs and auto-samplers
How do we supply Wasson-ECE Instrumentation in Romania?
We can quote Wasson-ECE process chromatographs from the Eclipse and Pup families, sample systems, small devices (auto-samplers, LPG vaporiser, Dynamic Blender) and parts for existing systems. Devices are supplied to order; usually 1–4 weeks for devices and simple parts, while chromatographs configured for an application can have a longer lead time. For a correct quotation we need: the analysed samples (composition, phase, pressure, temperature), the components to be measured and the concentration ranges, the detectors wanted, the Ex zone and, for replacements, the model from the nameplate. The exact lead time is confirmed in the quotation.
Local service for this range in Romania, commissioning and the analytical methods are clarified before ordering.
Frequently asked questions about Wasson-ECE Instrumentation
What does Wasson-ECE Instrumentation make?
Wasson-ECE, from Fort Collins (USA), active since 1986, builds process chromatographs (Eclipse, Pup), sample systems, auto-samplers for gases and liquids and GC devices such as the LPG vaporiser and the Dynamic Blender. It also has a production facility in the Czech Republic.
How do I choose between Eclipse and Pup?
Pup suits cases where the laboratory method has a single column and a single detector. Eclipse is chosen when multiple capillary columns, up to four detectors or two programmable ovens are needed. For a recommendation we need the list of components and the concentration ranges.
Do you supply Wasson-ECE equipment in Romania and how fast?
Yes, Wasson-ECE products are supplied to order: devices and simple parts usually within 1–4 weeks; chromatographs configured for an application can have a longer lead time, confirmed in the quotation after the configuration is checked.
Can I replace an existing auto-sampler or sample system?
This can be checked. What matters is the type of GC it works with, the number of sources, the sample pressure and the conditioning temperature. Send the nameplate model and the configuration of the analytical line for checking. We confirm compatibility once we have these details.
What data do I need to send for a quotation on a process chromatograph?
Send the sample composition and flow (gas or liquid, pressure, temperature), the components to be measured and the detection limits, the Ex zone of the site, the outputs needed to the DCS and, if there is one, the laboratory method you want to move into the process.
How do I request a Wasson-ECE Instrumentation quotation?
Send the Wasson-ECE Instrumentation code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Wasson-ECE Instrumentation (manufacturer documentation)