Welland & Tuxhorn supplier in Romania
Safety valves and steam bypass valves for power plants
Founded in 1901 · Headquarters: Bielefeld, Germany
Who is Welland & Tuxhorn and what does it make?
Welland & Tuxhorn is a German manufacturer of valves for power plants, based in Bielefeld. The company's roots go back to 1901, to a brass foundry in Brackwede, today a district of the city. Today the company makes control and safety valves for the steam and feed water circuits of coal-fired and combined cycle gas power plants, and of waste incineration, biomass, district heating, desalination, paper, sugar and chemical installations.
Production concentrates on the valves that decide the safety and flexibility of a power plant: safety valves for steam generators and superheaters (DUSI type 700, ZÜSI), high-, medium- and low-pressure turbine bypass valves (DUV type C4 and type A), high-pressure feed water control valves, injection coolers, dump tubes and condensate control valves. All are supplied with tightness to DIN 12266-1, rate A, and ANSI/FCI 70-2 class V respectively, and the type of actuator (hydraulic, pneumatic or electric) is freely selectable.
In Romania, the interest is practical: cogeneration plants, thermal power plants and industrial installations with process steam use such valves as project items, often a single piece. When a bypass valve or a control cylinder has to be replaced, the safe way is exact identification from the nameplate data, because the valves are made to measure for the installation.
What do we supply from the Welland & Tuxhorn range?
| Product | Description |
|---|---|
| DUSI type 700 — safety valve with steam conversion | Safety valve for steam generators and superheaters, with internal extraction of motive steam, single-stage control by a control piston and throttling cylinders, with the number of stages adapted to the application. |
| DUV type C4 and type A — steam conversion valves | Bypass valves for the turbine, with angle or Z body; type A includes cooling water injection through an integrated lance, controlled by the stem stroke, and type C4 has true two-stage control. |
| High-pressure feed water control valves | Forged valves, with straight, angle or Z body, weld ends to DIN or ANSI, with staged pressure reduction for minimum cavitation and erosion and characteristics tailored to the application. |
| Injection coolers, dump tubes and condensate valves | Auxiliary equipment of the bypass circuits: injection coolers, dump tubes for steam-water discharge into the condenser and condensate control valves, designed for conventional and combined cycle power plants. |
Why Welland & Tuxhorn?
- The DUSI type 700 valve combines the safety function with that of steam conversion — a single-source solution, with valve and actuator matched to each other
- Tightness to DIN 12266-1, rate A, and ANSI/FCI 70-2 class V respectively — on the DUSI and DUV series and on the feed water valves
- Wear parts replaceable on site, with screwed-in rather than welded internals — maintenance without removing the body from the pipe
- True two-stage control on the DUV type C4 — a combination of a ported body and a control cylinder, to reduce erosion
- Hydraulic, pneumatic or electric actuator to choose from — integrates with the existing automation system
Which Welland & Tuxhorn codes and series are requested most often?
| Code | Description |
|---|---|
| DUSI Typ 700 | Safety valve with steam conversion for generator and superheater |
| ZÜSI | Safety valve for reheater |
| DDPE | Steam pressure test device |
| DUV Typ C4 | Steam conversion valve, angle body, two-stage control |
| DUV Typ E34 | Straight or Z body variant of the C4 series |
| DUV Typ A | Steam conversion valve with integrated water injection lance |
| DUV Typ S | Angle body variant of the A series |
| Typ E20 / E22 | Steam conversion valves for medium- and low-pressure bypass |
| Dump Tube | Steam-water discharge tube to the condenser |
| Treibdampfkühler | Motive steam cooler |
| Einspritzkühler | Water injection cooler |
| HD-Speisewasserregelventile | High-pressure feed water control valves |
| HD-Speisewasserabsperrventile | High-pressure feed water isolation valves |
| Kondensatregelventile | Condensate control valves |
Where is Welland & Tuxhorn equipment used?
- Combined cycle gas power plants — turbine bypass and feed water
- Coal-fired and biomass power plants — safety valves for superheaters
- District heating and cogeneration — process steam circuits
- Waste incineration — control valves for steam generators
- Paper, sugar and chemical industry — process steam valves
How do we supply Welland & Tuxhorn in Romania?
We can take requests for bypass valves, safety valves for steam generators, feed water valves and wear parts of the Welland & Tuxhorn series. The item is identified from the valve nameplate: the type (DUSI, DUV, ZÜSI), the order number, the diameter, the design pressure and temperature, plus the actuator type. Supplied to order, and the lead time is usually 1–4 weeks; for valves made to a project the lead time may be much longer and is set in the quotation. Availability is checked for each code in the quotation.
A valve or a bypass valve is quoted from the design data of the installation, because the valves are sized individually for each power plant.
Frequently asked questions about Welland & Tuxhorn
What does Welland & Tuxhorn make?
The manufacturer from Bielefeld makes valves for the steam and water circuits of power plants: safety valves for steam generators, turbine bypass valves, feed water control valves, injection coolers and hydraulic, pneumatic or electric actuators.
How do I choose between DUV type C4 and DUV type A?
The main difference: type A also controls the cooling water injection through an integrated lance, controlled by the stem stroke, while type C4 uses two-stage control with a ported body. The choice depends on the pressures, flows and level of cooling required by the bypass.
Do you supply Welland & Tuxhorn valves in Romania and in what time?
Yes, the valves are supplied to order, usually in 1–4 weeks. Valves built to a project have longer lead times, which we confirm in the quotation.
Can I replace an old DUV valve with a new variant?
It depends on the design generation and on the installation data. Send us the type, the order number, the diameters, the design pressure and a photo of the nameplate, and we check which item can be ordered, with interchangeability confirmed case by case.
What information do you need for a bypass valve quotation?
We need the steam parameters at the inlet (pressure, temperature), the outlet parameters, the flow, the cooling water temperature, the type of body and ends, the tightness class and the type of actuator wanted, plus the installation drawing if you have it.
How do I request a Welland & Tuxhorn quotation?
Send the Welland & Tuxhorn code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Welland & Tuxhorn AG (manufacturer documentation)