Rectifier-chargers, DVR and active harmonic filters for substations
Headquarters: Vitoria-Gasteiz, Spain
Who is ZIGOR and what does it make?
ZIGOR (a brand also used in the form ZGR) is a Spanish power electronics manufacturer with its main office in Vitoria-Gasteiz, in the Basque Country, and offices in Madrid, Valencia, Mexico City and Bogotá. The company works in four areas: photovoltaic energy and storage, electricity transmission and distribution, industry and electric mobility. For a maintenance engineer, the relevant part is the DC supply of electrical substations and transformer stations, that is rectifier-battery chargers, plus power quality equipment: dynamic voltage restorers (DVR) and active harmonic filters.
The rectifier-chargers are built on two technologies. The ZGR MIT NG range uses a microprocessor-controlled thyristor bridge, in single-phase and three-phase versions, with galvanic isolation, charging for Ni-Cd and lead batteries and a MODBUS or SNMP communication gateway. The ZGR TELSIS APS range is modular, in high-frequency switch-mode, with automatic parallel load sharing and N+1 or N+2 redundant configurations, and ZGR TPS 120/200 NG are compact 48 V chargers for telecontrol, with automatic battery state test and an Ethernet interface.
The ZGR AVC DVR restorer corrects three-phase voltage sags of up to 70 % depth, without batteries, with a response time under 3 ms, and the ZGR FAA / AHF filter compensates harmonics up to the 50th order, in modules from 25 A to 600 A. Such equipment is found in substations and transformer stations, in railway infrastructure, in industrial plants with processes sensitive to voltage sags and in photovoltaic parks. For a replacement, the nameplate data matter: type, battery voltage, charging current and battery type.
What do we supply from the ZIGOR range?
| Product | Description |
|---|---|
| ZGR MIT NG — thyristor rectifier-charger | Battery chargers with a microprocessor-controlled thyristor bridge, single-phase and three-phase. Galvanic isolation, disconnection at minimum battery voltage, temperature and electrolyte level sensors, MODBUS or SNMP communication. They charge Ni-Cd and lead batteries, vented or sealed. |
| ZGR TELSIS APS — modular rectifier | Modular high-frequency switch-mode rectifier-chargers for telecommunications and industry, with parallel connection and automatic load sharing, N+1 or N+2 redundancy and web server supervision from a central unit. |
| ZGR TPS 120 and TPS 120/200 NG — compact chargers | 12, 24 or 48 V chargers (TPS 120) and 48 V chargers for lead or lithium batteries of up to 18 Ah (TPS 120/200 NG, 120 W and 200 W), for telecontrol and transformer stations. The NG series has an automatic or manual battery test, Ethernet and SNMP. |
| ZGR AVC DVR and ZGR FAA / AHF — power quality | AVC DVR compensates three-phase sags of up to 70 %, regulates the voltage to ± 1 % and works without batteries. FAA / AHF is a modular active harmonic filter in parallel with the load, from 25 A to 600 A, with resonance detection and an Ethernet or EtherCAT interface. |
Why ZIGOR?
- Thyristor rectifier-chargers (MIT NG) and switch-mode ones (TELSIS APS, TPS) — two technical lines for substations, transformer stations and telecommunications
- N+1 and N+2 redundant configurations on TELSIS APS — modules are added as the load grows, without initial oversizing
- Automatic battery state test on TPS 120/200 NG, with Ethernet access — detects weak batteries before a missed trip
- DVR without batteries, with a response time under 3 ms — corrects voltage sags in sensitive industrial processes
- Modular active harmonic filter, 25 A–600 A — compensates harmonics up to the 50th order and neutral imbalances
Which ZIGOR codes and series are requested most often?
| Code | Description |
|---|---|
| ZGR MIT NG | Thyristor rectifier-charger, single-phase or three-phase |
| ZGR MIT | Thyristor rectifier-charger from the MIT range |
| ZGR TELSIS APS | Modular switch-mode rectifier, N+1 / N+2 redundancy |
| ZGR SWIT NG | Rectifier-charger from the NG range |
| ZGR TPS 120 | Compact switch-mode charger, 12, 24 or 48 V |
| ZGR TPS 200 | Compact 48 V charger, 200 W |
| ZGR TPS 120/200 NG | Intelligent 48 V charger, 120 W / 200 W |
| ZGR AVC DVR | Dynamic voltage restorer, without batteries |
| ZGR AVC DVR HIGH POWER | High-power dynamic voltage restorer |
| ZGR FAA / AHF | Active harmonic filter, 25 A–600 A |
| ZGR PCS 3000 | Bidirectional converter for batteries |
| ZGR PCS 4500 | Bidirectional converter for batteries, larger version |
| ZGR DVC SEPEC 200-800 | Industrial UPS, 200–800 range |
| ZGR INFLUENCE HP 50-200 kVA | Professional UPS from 50 to 200 kVA |
| ZGR SCALABLE 60-300 kVA | Modular UPS from 60 to 300 kVA |
Where is ZIGOR equipment used?
- Substations and transformer stations — DC supply for protection, control and tripping
- Railway — active filters for harmonics in traction networks
- Industry — compensation of voltage sags in continuous processes (plastics, logistics, electronics)
- Telecommunications — redundant modular rectifiers for network nodes
- Photovoltaic — inverters, storage and zero-injection control
How do we supply ZIGOR in Romania?
We can quote ZIGOR rectifier-chargers, modules and power quality equipment, especially for replacing units already installed. They are supplied to order, usually in 1–4 weeks; for configured systems the lead time may be longer and is confirmed in the quotation. For a correct quotation we find useful the series and code from the nameplate (for example MIT NG or TELSIS APS), the battery voltage and type, the charging current, the mains voltage and frequency, and the supervision protocol required. For a DVR or a harmonic filter, add the load power and the depth of the measured sags.
The direct successor of a model withdrawn from production, with the same dimensions and the same communication, is identified from the nameplate.
Frequently asked questions about ZIGOR
What products does ZIGOR make?
ZIGOR (ZGR), based in Vitoria-Gasteiz in Spain, makes battery rectifier-chargers, UPS units, dynamic voltage restorers, active harmonic filters, photovoltaic inverters, storage converters and electric vehicle chargers. The company has offices in Madrid, Valencia, Mexico City and Bogotá, and its activity also covers the photovoltaic field.
How do I choose a ZGR rectifier-charger for a transformer station?
Start from the battery voltage, the charging current plus the permanent consumption of the protections, and the battery type (Ni-Cd or lead). For high reliability there is MIT NG with thyristors, and for modularity and N+1 redundancy there is TELSIS APS.
Do you supply ZIGOR equipment in Romania, and how quickly?
Yes, supplied to order: usually 1–4 weeks for standard products. For configured systems, for example a DVR or an AHF filter selected for the load, the lead time may be longer; it is established after the data are analysed and confirmed in the quotation.
What replaces an older MIT charger in my DC board?
A direct replacement is confirmed after checking. The output voltage, the current, the battery type, the cabinet dimensions and the supervision protocol matter. Send the nameplate and the diagram of the existing charger, and we identify which current version is suitable. A photo of the nameplate and the terminals greatly shortens the check of dimensions and output voltage.
What data do I need to send for a quotation on a DVR or a harmonic filter?
For a DVR: the load voltage and power and the depth of the measured sags. For an AHF filter: the mains voltage, the current to be compensated, the dominant harmonic orders from the power quality analysis and the number of modules desired. For a DVR, the measurement of sags over the last months is also useful, and for an AHF the harmonic analysis on each phase.
How do I request a ZIGOR quotation?
Send the ZIGOR code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: ZIGOR (manufacturer documentation)