Cryocoolers and Cryogenic Cooling Systems

A cryocooler cools an object to cryogenic temperatures without using cryogenic liquid, by cyclically compressing and expanding a gas, usually helium. It is used to cool detectors, superconducting magnets, cryogenic vacuum pumps and scientific instruments, in place of a continuous supply of liquid nitrogen or helium. The target temperature and the cooling power available at that temperature determine the model, and vibration requirements and compressor cooling complete the specification.

A cryocooler is a closed refrigeration machine that produces temperatures of tens of kelvin or even lower, with an external compressor and a cold head in which the gas expands. The main types are Gifford-McMahon, with a displacer piston in the cold head, pulse tube, with no moving parts in the cold zone, and Stirling, which is compact and used to cool detectors. The choice depends on the target temperature, the cooling power available at that temperature and the installation's tolerance to vibration, because the cold head of some models transmits mechanical vibration.

Cooling power is specified at a given temperature and falls as the target temperature drops, so a catalogue value cannot be compared without this context. The compressor is air-cooled or water-cooled and requires high-pressure gas connections to the cold head. Cryocoolers are used with superconducting magnets, spectrometers, vacuum systems with cryogenic pumps and infrared detector cooling, and cool-down time and the interval between overhauls affect operating cost.

How to choose

Target temperature of the load

Set the working temperature of the object being cooled; the type of cryocooler and the available power depend directly on this value.

Cooling power at that temperature

Power is stated at a precise temperature and falls when it drops; compare models at the same reference temperature, not isolated catalogue figures.

Cycle type

Gifford-McMahon covers a wide range of powers, the pulse tube reduces vibration in the cold zone, and Stirling is compact; choose according to the application requirements.

Permitted vibration and noise

Sensitive instruments, for example microscopes or detectors, may require a low-vibration model or mechanical isolation of the cold head.

Compressor cooling and electrical power

The compressor is air-cooled or water-cooled; check the three-phase or single-phase supply available and the cooling circuit in the installation.

Service interval and service life

The moving parts in the cold head and the adsorber in the compressor are replaced after a number of hours; compare overhaul intervals on equivalent models.

Interface with the installation

Check the flanges, the high-pressure gas connections, the permitted mounting orientation and compatibility with the vacuum chamber or cryostat.

What to send for a quotation

  • The desired working temperature for the cooled load
  • The cooling power required at that temperature
  • The application: magnet, detector, cryogenic pump or scientific experiment
  • Requirements for vibration, noise and mounting orientation
  • The compressor cooling type and the electrical supply available
  • The quantity wanted and the delivery date

Typical applications

  • Superconducting magnets and spectrometers
  • Cryogenic pumps for vacuum chambers
  • Infrared detectors and imaging systems
  • Low-temperature physics research

Maintenance and spare parts

Cryocoolers require scheduled overhaul after a number of operating hours, set for the model concerned: the cold head has moving parts that wear, and the adsorber in the compressor saturates over time and must be replaced. Helium pressure and cooling water temperature are monitored, and a drop in performance usually indicates the need for an overhaul. Gas hoses are checked for leaks and kinks.

Brands we quote for this product type

Frequently asked questions

What is the advantage of a cryocooler over cooling with liquid nitrogen or helium?

A cryocooler works without periodic liquid supply, so it needs no refilling, transport or handling of cryogenic fluids. After installation it needs only electricity and, on some models, cooling water. The drawbacks are the higher initial investment, the vibration of some models and scheduled maintenance. In continuous use or in places that are hard to supply, the difference is recovered over time.

Why can't I compare the cooling power in the catalogues of different cryocoolers directly?

Because cooling power depends strongly on the temperature at which it is measured. At lower temperatures the available power drops sharply, so a model that gives a high value at a higher temperature is not necessarily better at a lower one. The comparison is made only at the same reference temperature, the same mains frequency and the same compressor cooling conditions.

What data should I send for a cryocooler quotation and how long does delivery take?

State the working temperature, the power required at that temperature, the application, the vibration requirements, the electrical supply and the compressor cooling type. Also mention whether you are replacing an existing model, with its code. Delivery is 24–72 h when the item is in stock, locally or at the supplier; to order, usually 1–4 weeks, and depending on brand and specification it can take longer.

What is a cold head and what is the compressor in a cryocooler?

The cold head is the part where the gas expands and produces the cold; the object to be cooled is fixed to it. The compressor is the separate unit that compresses the working gas, usually helium, and sends it through hoses to the cold head. Together they form a closed circuit, so the gas is not consumed, but the pressure level and the cleanliness of the circuit must be checked periodically.