Braking resistors, reactors and harmonic filters

Braking resistors dissipate the energy regenerated by motors when stopping, reactors limit currents and harmonics, and passive, active, sine-wave and EMC filters protect the network and the motors. They are basic components of installations with frequency inverters and of high-power electric drives.

When a motor brakes a load with high inertia or lowers a load, it acts as a generator, and the energy reaches the DC circuit of the inverter. The braking resistor dissipates this energy as heat, so that the voltage does not rise above the limit. The line or motor reactor, a coil in series with the line, flattens the current, limits the short-circuit current and reduces harmonics. Harmonics are currents at integer multiples of the 50 Hz frequency, produced by the rectifiers of inverters, and they heat cables and transformers. Passive harmonic filters reduce them with coils and capacitors, while active filters inject a compensating current. Sine-wave filters and dv/dt coils smooth the voltage at the inverter output, and EMC filters limit radio interference. Large networks also use static reactive power compensators, and earthing resistors limit the neutral fault current.

How to choose

Braking power and duty cycle

The braking resistor is chosen from the energy dissipated in one stop, the average power and the braking frequency. A repeated cycle, as on cranes, requires a higher continuous power than an occasional stop.

Resistance value and circuit voltage

The ohmic value must respect the limits of the inverter, and the insulation voltage must match the DC circuit. A value that is too low overloads the braking transistor.

Harmonics and network requirements

The current and voltage distortion accepted at the point of connection decides between a line reactor, a passive filter or an active filter. An active filter is chosen when loads vary or a low distortion level must be reached.

Motor cable length and output filters

Long cables and sensitive motors require dv/dt coils or sine-wave filters, which reduce the stress on the winding insulation and the leakage currents.

Protection, ventilation and IP rating

Resistors get very hot: they are mounted with free space, thermal protection and, if needed, in ventilated enclosures. The environment decides the degree of protection and the materials.

Application: braking, load or earthing

Braking resistors, load resistors for testing and neutral earthing resistors have different constructions and standards, so the role must be specified before the quotation.

What to send for a quotation

  • The inverter or drive type: power, voltage, current and the minimum permitted braking resistor value.
  • The duty cycle: the energy or power to be braked, and the duration and frequency of stops.
  • Network requirements regarding harmonics or interference, if any.
  • The motor cable length and the motor type.
  • Installation conditions: temperature, degree of protection, ventilation space.
  • The required quantity and the delivery date you need.

Typical applications

  • Cranes, lifts and lifting machines
  • Production lines with frequency inverters
  • Industrial networks with non-linear loads
  • Railway traction and renewable energy

Maintenance and spare parts

Braking resistors are inspected visually for overheating, discoloration and connections, and ventilation is kept free. Reactors and filters are checked for temperature, noise and terminal tightness; the capacitors of passive filters age and are checked periodically. Active filters need their fans cleaned. The spare parts usually requested are resistors, fuses, fans and capacitors.

Brands we quote for this product type

Frequently asked questions

When is a braking resistor needed?

When the load has high inertia or when it stops quickly or is lowered, the motor regenerates energy into the inverter. If the energy cannot be returned to the mains, the braking resistor converts it into heat and prevents the inverter from tripping on overvoltage.

What is the role of a line reactor on a frequency inverter?

The reactor in series with the supply limits short-circuit currents, attenuates the current peaks of the rectifier and reduces the harmonics injected into the network. It also protects the inverter from mains disturbances.

What is the difference between a passive and an active harmonic filter?

The passive filter uses coils and capacitors tuned to specific harmonics and is simple and robust. The active filter measures the current and produces a compensating waveform, so it adapts to variable loads and achieves low distortion.

What is the sine-wave filter at the inverter output used for?

It smooths the stepped voltage of the inverter into a nearly sinusoidal shape, which reduces stress on the motor insulation, noise and leakage currents, especially with long cables or older motors.

What do I send for a quotation and how long does delivery take?

We need the inverter data, the braking cycle, the harmonic requirements and the installation conditions. Delivery is to order, typically 1–4 weeks, depending on the manufacturer and the chosen version; specially sized resistors and filters may take longer.