Non-Destructive Testing and Materials Testing
Non-destructive testing (NDT) detects defects and measures thickness in welds, pipes, plate and castings without damaging them, using ultrasound, eddy currents, X-rays or magnetic flux. Materials testing machines, by contrast, measure the resistance of specimens to tension, compression, impact or hardness.
The main non-destructive testing methods are ultrasound (flaw detectors and thickness gauges, including phased array and TOFD), eddy currents (for surface and near-surface defects in conductive metals), X-ray or gamma radiography, in digital form or on imaging plates, and magnetic flux (for corrosion in tank floors and pipes). Guided waves allow a length of pipe to be checked from a single access point, and electromagnetic acoustic transducers (EMAT) generate ultrasound in metal without couplant. Coating thickness gauges measure a paint or zinc layer by magnetic induction, eddy currents or X-ray fluorescence. The result depends on the operator: personnel carrying out the inspection are qualified and certified to EN ISO 9712.
Materials testing machines apply a controlled force to a specimen and record its deformation. The universal testing machine performs tension, compression and bending tests (for metals, the usual standard is ISO 6892-1), the Charpy pendulum measures impact resistance (ISO 148-1), and Brinell, Vickers and Rockwell hardness testers measure hardness. Servo-hydraulic systems reproduce repeated loads for fatigue tests and vibration simulations. Periodic verification of the force and of the extensometer, to ISO 7500-1, makes results comparable between laboratories.
How to choose
Material, defect sought and method
Ultrasound finds internal defects in metals and composites, eddy currents find surface defects in conductive materials, radiography shows the volume of the part, and magnetic flux reveals material loss through corrosion. The method is chosen by the defect, not by the instrument.
Access to the part and coupling
Ultrasonic probes need a couplant between the probe and the part, and rough or hot surfaces make inspection difficult. EMAT systems and water-jet or immersion systems avoid the couplant. For long or hard-to-reach pipes, guided waves can be chosen.
Portable, semi-automatic or automatic
Manual inspection is done with portable instruments, repetitive inspection of bars, pipes and plates calls for automatic systems with scanners and multiple probes, and aerospace or composite parts are checked in immersion tanks. The throughput of parts and the documentation required call for a matching level of automation.
Documenting the results
Modern instruments store the signal and the image (A-scan, B-scan, C-scan), which allows review and reporting. The software must produce reports accepted by the customer and by inspection bodies.
Standards, qualification and environment
The inspection procedure follows the standard applicable to the product (welds, pipes, plate), and the operator must be certified. In explosive atmospheres, intrinsically safe instruments are chosen.
Testing machines: force, accuracy and accessories
The machine capacity is chosen from the maximum specimen force, with a margin, and the accuracy class is verified to ISO 7500-1. Grips, extensometer, climatic chamber and evaluation software are chosen according to the specimen standard (metals, plastics, composites, cement).
What to send for a quotation
- The material, the thickness of the part or specimen, and its shape (weld, pipe, plate, casting).
- The defect or quantity sought (crack, corrosion, thickness, coating thickness, hardness, strength).
- The inspection or test standard that applies.
- Place of use: laboratory, production line or field, and any explosive atmosphere zone.
- Whether the inspection is manual or automatic and what documentation is required.
- The quantity needed and the requested delivery date.
Typical applications
- Welds, pipes and pressure vessels
- Tanks and pipelines
- Aerospace, rail and composites
- Testing laboratories
Maintenance and spare parts
Probes and cables are the parts with predictable wear; contact probes wear on the face and are checked periodically. Inspection instruments require verification and calibration at intervals set by procedure, using reference blocks. For testing machines, the load cell and the extensometer are checked periodically, and the grips are cleaned and inspected. The parts usually requested are probes, cables and grips.
Brands we quote for this product type
Frequently asked questions
What is the difference between conventional ultrasonic testing and phased array?
A conventional flaw detector uses a single-element probe, which emits a beam in one direction. Phased array uses a probe with several electronically controlled elements, which allows the beam to be steered and focused and a cross-sectional image of the part to be obtained. The method produces images that are easy to interpret and archive, but it requires a more complex instrument and probes.
When are eddy currents chosen instead of ultrasound?
Eddy currents are suitable for surface and near-surface defects in conductive materials, at high inspection speeds and without couplant, for example on bars, pipes and cast components. Ultrasound is chosen when the defect is in the volume of the part or when the thickness is large.
Why is operator certification needed in non-destructive testing?
The result of the inspection depends on how the signal is set up and interpreted. Personnel are qualified and certified to EN ISO 9712, by method and level, and the inspection procedure is written and approved. A high-performance instrument does not replace the competence of the operator.
How is the thickness of a paint or zinc layer measured?
On steel, magnetic induction is used; on non-ferrous metals, eddy currents; and on any substrate, ultrasound or X-ray fluorescence. The instrument is calibrated on the actual substrate or on reference plates, otherwise the measurement is unreliable.
What does a universal testing machine measure?
It applies a tensile, compressive or bending force to a specimen and records the force and the deformation. From the resulting curve, the tensile strength, yield strength and elongation are calculated. For metals, the usual procedure is the one in ISO 6892-1.
What do I send for a quotation for an inspection or testing instrument, and how long does delivery take?
The material, thickness, defect sought, applicable standard, place of use and level of automation are needed. Delivery is to order, usually in 1–4 weeks, depending on the manufacturer and the configuration chosen; automated systems are built to order and may take longer.
Updated: 2026-11-12