Mass flow meters and controllers for gases and liquids

Headquarters: Tucson, Arizona, USA

Request a quote

Who is Alicat Scientific and what does it make?

Alicat Scientific is an American manufacturer of mass flow meters and controllers for gases and liquids, as well as pressure controllers, based in Tucson, Arizona. The core technology is mass flow measurement by laminar differential pressure (laminar DP), the company's own invention: the same cell measures mass flow, volumetric flow, temperature and pressure.

For a process engineer or a metrologist, the difference from classic thermal flow meters is the wide control range, down to 0.01–100% of full scale (10,000:1 ratio), and a control response of up to 30 ms on the MC series. The instruments are built for low flows, from the laboratory to dosing in industrial processes: thin-film deposition, gas mixtures, bioreactors, leak testing, hydrogen, semiconductors.

Several series have versions for corrosive fluids (MCS, PCS, LCS) or for hazardous areas (the -X option for Class I Div 2). The instruments remain relevant for research laboratories, pilot lines and dosing installations, where the accuracy requirements are higher than for an ordinary industrial controller. For an order, the series, the gas or liquid, the flow range, the working pressure and the connection type matter. The series and the calibration gas, read from the nameplate of the existing instrument, help to identify a replacement.

What do we supply from the Alicat Scientific range?

ProductDescription
MC and MCS series (mass flow controllers for gases)Laminar DP controllers with an accuracy of ±0.5% of reading or ±0.1% of full scale, control time of up to 30 ms; the MCS has reduced wetted materials and preloaded calibrations for up to 130 gases.
M and MQ series (mass flow meters for gases)Flow meters with a range of up to 10,000:1 and an accuracy of ±0.5% of reading; the MQ series measures very low flows, at small gas quantities.
PC, PCS, PCX series (pressure controllers)Pressure controllers with a programmable display, absolute or gauge; PCS for corrosive fluids, PCX for maximum corrosion resistance and metal seals.
LC and LCS series (liquid flow controllers)Laminar DP controllers for non-corrosive (LC) or corrosive (LCS) liquids, with the -X option for areas with an explosion risk.

Why Alicat Scientific?

  • Laminar DP measurement — a single cell gives mass flow, volumetric flow, temperature and pressure, which simplifies installation
  • Control ratio up to 10,000:1 on the M and MC series — a single instrument covers wide flow ranges
  • Versions for corrosive fluids (MCS, PCS, LCS) — reduced wetted materials for aggressive media
  • -X option for hazardous areas, on the LC series — for liquids and gases in potentially explosive environments
  • PC, PCS and PCX pressure controllers — special PCX series for maximum corrosion resistance and metal seals

Which Alicat Scientific codes and series are requested most often?

CodeDescription
MCMass flow controller for gases, laminar DP
MCSFlow controller for corrosive gases, reduced wetted materials
MMass flow meter for gases, laminar DP
MQMass flow meter for very low flows
BASISCompact thermal MEMS controller for OEM
PCStandard pressure controller
PCSPressure controller for corrosive fluids
PCXPressure controller with metal seals
LCFlow controller for non-corrosive liquids
LCSFlow controller for corrosive liquids
LC-XLiquid controller, version for Class I Div 2 areas

Where is Alicat Scientific equipment used?

  • Research and metrology laboratories — calibration and flow standards
  • Semiconductors and thin-film deposition — precise gas dosing
  • Bioreactors and fermenters — gas control in biological processes
  • Hydrogen and power — flow and pressure monitoring
  • Leak testing and gas mixtures — pilot and industrial installations

How do we supply Alicat Scientific in Romania?

We can quote Alicat flow meters and controllers for laboratories and process installations. Supply is to order, usually in 1–4 weeks; for special configurations the lead time can be longer and is confirmed in the quotation. For an accurate quotation we need the series wanted (for example MC, M or PC), the gas or liquid measured, the flow or pressure range, the working pressure, the connection type and the communication protocol. If you are replacing an existing instrument, send the full code from the nameplate, because the range and the calibration are part of the order code.

Calibration for a particular gas or mixture is checked on the basis of the gas and mixture data, and calibration certificates are obtained through an accredited laboratory.

Frequently asked questions about Alicat Scientific

What products does Alicat Scientific make?

Alicat makes mass flow meters and controllers for gases and liquids, pressure controllers and gas blending systems. The core technology is laminar differential pressure, and the American headquarters is in Tucson, Arizona.

How do I choose between the M, MC and BASIS series?

The M is a flow meter, the MC is a controller with a valve, and the BASIS is a compact thermal controller for OEM, with 9 preloaded gases. The choice depends on the gas, the flow range and the need for a wide range (laminar DP) or a small footprint.

Can you supply Alicat products in Romania, and within what lead time?

Yes, to order. For most items, to order, usually 1–4 weeks. Calibrations and special configurations may extend the lead time, and the exact date is confirmed in the quotation.

Can I replace an old Alicat instrument with a new model?

Possibly; equivalence is confirmed on the basis of the data. We need the full code from the nameplate (series, range, gas, connection), the working pressure and the communication interface, on the basis of which we check the current version.

What details should I specify for a quotation for a flow controller?

The gas or liquid, the minimum and maximum flow, the inlet and outlet pressure, the temperature, the connections and the output wanted (analogue, RS-232, Modbus etc.). For corrosive fluids, state the composition, so that we can check whether the MC or the MCS fits.

How do I request a Alicat Scientific quotation?

Send the Alicat Scientific code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote