Brooks Instrument supplier in Romania

For Brooks Instrument we quote SLA5800 and GF040 mass flow controllers, Quantim QMC Coriolis flowmeters, MT3809 flowmeters and PC100 pressure regulators; we need the gas or liquid, the flow range, the pressure and the interface.

Headquarters: Hatfield, Pennsylvania, USA

Request a quote

Who is Brooks Instrument and what does it make?

Brooks Instrument is an American manufacturer of flow, pressure and vacuum instrumentation, based in Hatfield, Pennsylvania. The programme is divided into thermal mass flowmeters and controllers for gases, Coriolis flowmeters and controllers, variable area flowmeters (metal or glass tube), clamp-on ultrasonic flowmeters, pressure regulators and pressure and vacuum measuring instruments. Applications range from chemicals and petrochemicals to energy, water treatment and the food industry.

For gases, the SLA5800 family, with a flow range of 0.003–2500 slpm, a maximum pressure of 1500 psi and a repeatability of 0.20 % of set point, has the SLAMf version with IP66 protection; the GF series (GF040, GF080, GF100, GF120xHT for high temperatures) completes the segment, while 5850EM and 5800E are other series in the programme. For very low flow rates, Quantim QMC is a Coriolis flowmeter and controller for gases and liquids, from 1 to 27,000 g/h, with an accuracy of 0.2 % of flow rate on liquids. Variable area flowmeters include MT3809, with a metal tube and temperatures between −198 and 420 °C, MT3750, GT1600 and Sho-Rate. BCU is a clamp-on ultrasonic flowmeter for liquids, while PC100 and 5866RT are pressure regulators.

For industry in Romania, the range is of interest for gas dosing installations, laboratories and pilot lines, and chemical and water treatment processes where flow or pressure must be finely regulated. Brooks instruments are encountered by process and maintenance engineers who already have them in their plant.

What do we supply from the Brooks Instrument range?

ProductDescription
SLA5800 and SLAMfThermal mass flow controllers and flowmeters for gases, 0.003–2500 slpm, up to 1500 psi, repeatability 0.20 % of set point; SLAMf has IP66 protection.
GF040, GF080, GF100 and GF120xHTGF series of thermal mass flow controllers: GF040 with elastomer sealing (3 sccm–50 slpm), GF080 with metal sealing (3 sccm–55 slpm), GF100 with an EtherCAT version and GF120xHT for 45–150 °C.
Quantim QMCCoriolis flowmeters and controllers for gases and liquids, 1–27,000 g/h, maximum pressure 1500 psi, accuracy 0.2 % of flow rate on liquids; IP40, IP65 and IP66 versions, chosen according to the installation environment.
MT3809, MT3750, GT1600 and Sho-RateVariable area flowmeters: MT3809 with a metal tube (−198…420 °C), MT3750 (up to 4000 psi), GT1600 with a glass tube and Sho-Rate for low flow rates. The series are chosen according to fluid, flow rate and temperature.

Why Brooks Instrument?

  • SLA5800 / SLAMf family, from 0.003 to 2500 slpm — thermal mass flow controllers with IP66 on the SLAMf version
  • Quantim QMC Coriolis, 1–27,000 g/h — direct mass measurement, on gases or liquids, at low flow rates
  • MT3809 variable area flowmeters, from −198 to 420 °C — a very wide temperature range for gases and liquids
  • GF series with a high-temperature version (GF120xHT) and EtherCAT (GF100) — integration into modern control systems
  • BCU clamp-on ultrasonic flowmeter — measurement without interrupting the pipe, for liquids

Which Brooks Instrument codes and series are requested most often?

CodeDescription
SLA5800Thermal mass flow controller, 0.003–2500 slpm
SLAMfThermal mass flow controller with IP66 protection
GF040Thermal mass flow controller, elastomer sealing
GF080Thermal mass flow controller, metal sealing
GF100Thermal mass flow controller, with EtherCAT version
GF120xHTThermal mass flow controller for high temperatures
5850EMThermal mass flow controller with metal sealing
5800EThermal mass flow controller with elastomer sealing
GP200Pressure-based mass flow controller
Quantim QMCCoriolis flowmeter and controller, 1–27,000 g/h
BCUClamp-on ultrasonic flowmeter
MT3809Metal tube flowmeter, −198…420 °C
MT3750Metal tube flowmeter, up to 4000 psi
GT1600Glass tube flowmeter
Sho-RateGlass tube flowmeter for low flow rates
PC100Pressure regulator with metal sealing

Where is Brooks Instrument equipment used?

  • Chemicals and petrochemicals — mass flowmeters and pressure regulators
  • Energy and energy transition — precisely regulated gases and liquids
  • Water treatment — clamp-on ultrasonic and variable area flowmeters
  • Food and beverages — flowmeters for gases and process liquids
  • Laboratories and pilot lines — process gas control

How do we supply Brooks Instrument in Romania?

From the Brooks Instrument programme we can quote thermal mass flowmeters and controllers, Coriolis flowmeters, variable area flowmeters, pressure regulators and vacuum instruments, by series and complete code. Variable area flowmeters can ship in 24–72 h when the item is in stock, locally or at the supplier; mass flow and Coriolis controllers we order, usually 1–4 weeks, with a longer lead time for gas-specific configurations. For a quotation we need the series, the gas or liquid, the minimum and maximum flow rate, the working pressure and temperature, the sealing and the signal interface (analogue or digital).

Calibration for a specific gas or liquid is set from the fluid's process data and the complete code of the instrument.

Frequently asked questions about Brooks Instrument

What does Brooks Instrument make?

Brooks makes thermal mass flowmeters and controllers, Coriolis flowmeters, variable area and ultrasonic flowmeters, pressure regulators and pressure and vacuum measuring instruments. It is based in Hatfield, Pennsylvania. Applications range from chemicals and petrochemicals to water treatment.

How do I choose between a thermal and a Coriolis mass flow controller?

The thermal type measures gas flow from heat transfer and depends on the gas in the process, while Coriolis (Quantim QMC) measures mass directly, for gases or liquids, at low flow rates. Send us the fluid, the flow range, the pressure and the accuracy wanted.

Can you deliver Brooks instruments in Romania, and in what time?

Yes. Flowmeters can ship in 24–72 h when the item is in stock, locally or at the supplier; mass flow controllers, ordered by code, in about 1–4 weeks. Controllers configured for a gas and flow rate may have a longer lead time, confirmed in the quotation.

Can I replace an existing mass flow controller with one from the SLA5800 series?

It depends on the connection, the command signal, the sealing and the gas. Direct replacement between two models is confirmed from the data. Send us the complete code from the nameplate, the gas, the flow range and the interface used, and then we check the corresponding version.

What data is needed for a quotation on a variable area flowmeter?

You need to specify the fluid (gas or liquid), the minimum and maximum flow rate, the working pressure and temperature, the connection size and the tube material. For MT3809 or MT3750, also say whether you need an electrical output or flow limiters.

How do I request a Brooks Instrument quotation?

Send the Brooks Instrument code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote