Bürkert Sensors supplier in Romania
Flow sensors and fluid technology
Founded in 1946 · Headquarters: Ingelfingen, Germany
Who is Bürkert Sensors and what does it make?
Bürkert is a global supplier of measurement, control and regulation technologies for fluids and gases - from simple solenoid valves to complete process control systems with IoT. The manufacturer has over 75 years of activity and covers industries from pharmaceutical to semiconductor. The Bürkert philosophy: integrated solutions - a single supplier for valves, sensors, controllers and analysis software.
The Bürkert sensor range covers the usual fluid parameters: flow (thermal mass, electromagnetic, ultrasonic, Coriolis), pressure (piezoresistive, capacitive), temperature (Pt100, thermocouples), conductivity, pH and turbidity. For hygienic applications, Bürkert offers versions with hygienic design.
What do we supply from the Bürkert Sensors range?
| Product | Description |
|---|---|
| Type 8400 Temperature Transmitter | According to Bürkert's technical documentation, Type 8400 is a threshold detector and temperature transmitter with a large display, screw-in or wall mounting, and a 4-20 mA output to the PLC. The manufacturer has announced the withdrawal of this type from 1 January 2025. For flow measurement we choose the suitable type together, depending on the fluid and the process connection. |
| Type 8701 Mass Flow Meter | According to Bürkert's technical documentation, Type 8701 is a mass flow meter (MFM) for gases, with a thermal MEMS sensor, a nominal range from 0.010 to 80 l/min and calibration for two gases, switchable by the user. The manufacturer withdrew the type from 1 July 2025; the indicated successor is Type 8741. |
| Type 8314 Pressure Transmitter | According to Bürkert's technical documentation, Type 8314 is an OEM pressure transmitter with a ceramic measuring cell, in a two-wire design. The manufacturer withdrew it on 31 December 2012, with Type 8316 as its successor. |
| Type 8905 Analytical Controller | According to Bürkert's technical documentation, Type 8905 is an online water analysis system with an integrated 7-inch touch display, modular, which can measure up to 8 water quality parameters (for example pH, chlorine, conductivity, redox potential, turbidity, temperature). The supply voltage is 20-30 V DC. |
Why Bürkert Sensors?
- Sensor range - flow, pressure, temperature and water analysis, according to the manufacturer's documentation
- IO-Link + PROFINET - Industry 4.0 integration, remote diagnostics
- CIP/SIP - compatibility depends on the type (for example, Type 8098 is listed as CIP/SIP compatible)
Which Bürkert Sensors codes and series are requested most often?
| Code | Description |
|---|---|
| Type 6027 | Solenoid valve for general fluid automation applications |
| Type 2103 | 2/2-way diaphragm valve, pneumatically actuated, stainless steel |
| Type 3360 | Motorised valve with simple installation and modern control |
| Type 8652 | Valve island and process interface for automation |
| Type 8098 | FLOWave flow meter with surface acoustic waves (SAW), for hygienic applications |
| Type 6712 | 2/2-way valve with media separation and low switching noise (Whisper Valve) |
| Type 8741 | Mass flow meter or mass flow controller for gases, with thermal MEMS sensor |
| Type 2875 | 2/2-way proportional valve, direct-acting electromagnetic |
Where is Bürkert Sensors equipment used?
- Pharmaceutical - Bioreactor, sterile filling, CIP/SIP
- Food & Beverage - Dairy, brewing, soft drinks, processing
- Chemical - Batch reactors, continuous process, dosing
- Water Treatment - Drinking water, wastewater, desalination
- Semiconductor - Ultra-pure water, chemicals delivery, gas control
- Biotechnology - Fermentation, cell culture, downstream
- Cosmetics - Mixing, emulsification, filling
- Oil & Gas - Metering, injection, separator control
- Power Generation - Cooling water, steam, chemical dosing
- Automotive - Paint mixing, cooling circuits, testing
How do we supply Bürkert Sensors in Romania?
For Bürkert sensors and valves we work from the manufacturer's technical documentation, and the availability of each type is confirmed in the quotation. Products are usually supplied in 1–4 weeks to order; a few frequently requested types can ship in 24–72 h when the item is in stock, locally or at the supplier. Tell us the measured parameter (flow, pressure, temperature), the working range and the process connection, so that we can identify the suitable version. Versions with hygienic-design certification or extended calibration usually need more time for confirmation.
The availability of each Bürkert sensor variant is checked on request; calibration is carried out in a specialised laboratory.
Frequently asked questions about Bürkert Sensors
Which Burkert valves are suitable for controlling fluid processes?
For process control, the Type 2103 series offers pneumatically actuated diaphragm valves, while Type 2875 is a proportional valve with electromagnetic actuation, for applications that need fine control of flow or pressure. The choice between variants depends on the type of fluid, the working pressure and whether the installation already has compressed air available for pneumatic actuation.
What information do I send for a quotation for a replacement Burkert valve?
The full type marked on the valve (for example Type 6027 or Type 8652), the working pressure and temperature, the type of fluid and the control voltage in the installation are enough for a quotation. For the Type 8741 mass flow meters, also tell us which gas you are measuring, for correct calibration.
Do you supply Burkert equipment in Romania?
We handle Burkert valves and mass flow meters on request only, starting from the datasheets that the German manufacturer publishes for each type. The time until the goods arrive is usually 1–4 weeks to order, depending on the electrical configuration and the type of fluid controlled.
What is the difference between a pneumatically actuated Burkert valve and a motorised one?
The pneumatically actuated valve, such as the basic Type 2103, uses compressed air to open or close the shut-off element, making it fast and simple where air is already available in the installation. The motorised version integrates an electric motor for positioning, useful when there is no compressed air network or when the process requires fine control of intermediate position.
How do I request a Bürkert Sensors quotation?
Send the Bürkert Sensors code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Burkert Fluid Control Systems, Bürkert Fluid Control Systems, Wikipedia (manufacturer documentation)

