Cla-Val supplier in Romania
Automatic control valves for water networks
Founded in 1936 · Headquarters: Costa Mesa, USA
Who is Cla-Val and what does it make?
Cla-Val is an American manufacturer of automatic control valves for water networks, founded in 1936 and based since 1954 in Costa Mesa, California, where its main factory with in-house metal foundries also operates. The range covers valves for municipal water networks (pressure reduction and sustaining, level control, flow control, air valves and check valves), fire protection systems, equipment for marine, aviation and rail fuelling, plus electronic control components. From this range we can quote the valves intended for water networks and pumping stations.
Technically, Cla-Val operates two foundries of its own, which allows it to cast parts in over 50 variants of metals and grades - ductile iron, bronze, aluminium, steel and stainless steel. Cla-Val has its own subsidiaries in Canada, Switzerland, France, the United Kingdom and New Zealand.
For Romania, Cla-Val valves make sense at pumping stations of drinking water networks, in pressure-reducing systems of distribution networks and in fire protection installations where an automatic, hydraulically piloted valve is needed.
What do we supply from the Cla-Val range?
| Product | Description |
|---|---|
| Pressure Reducing and Control Valves | Automatic hydraulic valves that keep the outlet pressure constant regardless of flow variations or inlet pressure, used in municipal water distribution networks and at pumping stations where the downstream pressure must be limited. For a quotation, the customer must provide the pipe diameter, the inlet pressure and the desired outlet pressure. |
| Level Control Valves | Valves that automatically close or open the supply to a tank depending on the water level, used on storage tanks in drinking water distribution systems. They remove the need for an electrical control system for the basic fill-and-stop function. The customer must specify the pipe diameter and the type of level sensor used (float or electrode). |
| Flow Rate and Flow Control Valves | Valves that limit the maximum flow through a pipe to a preset value, regardless of the available pressure, used in water networks where overloading a section of the system must be avoided. The customer must provide the maximum permitted flow rate and the diameter of the pipe on which it is installed. |
| Fire Protection Valves | Control valves dedicated to hydrant and sprinkler systems, designed to maintain the pressure and flow required in a fire situation. They integrate into mixed drinking-water and fire-water supply networks. The customer must state the pipe diameter and the minimum flow rate required by the fire protection design. |
Why Cla-Val?
- In-house metal foundries - over 50 variants of metals and grades available
- Three generations of family management - company founded in 1936, according to the manufacturer's information
- Range of automatic control valves for water, fire protection, marine, fuel and industry
- Multi-sector coverage - municipal water, fire protection, marine, aviation and rail from the same range
Which Cla-Val codes and series are requested most often?
| Code | Description |
|---|---|
| 90-01 / 690-01 | pressure reducing valve, available in the 90-01 and 690-01 series |
| 90-01KO / 690-01KO | pressure reducing valve with anti-cavitation protection |
| CRD-L | pressure reducing valve |
| 92-01 / 692-01 | pressure reducing and sustaining valve |
| 92-07 / 692-07 | pressure reducing, sustaining and solenoid shut-off valve |
| 93-01 / 693-01 | pressure reducing valve with electric solenoid shut-off |
| 90-05 / 690-05 | pressure reducing valve with return flow |
| 90-48 / 690-48 | pressure reducing valve with low-flow bypass |
| 90-66 / 690-66 | additional pressure reducing valve variant |
| 590-01 / 6590-01 | pressure reducing valve, 590 series variant |
| 94-01 / 694-01 | pressure and surge control valve |
| 95-01 / 695-01 | Ratio Reduction control valve (reduction by ratio) |
| 90-37 / 690-37 | pressure reducing valve variant from the 37 series |
| 90-99 | pressure reducing valve with low-flow bypass |
| 94-22 / 694-22 | pressure reducing, sustaining and surge control valve |
| 94-58 / 694-58 | pressure reducing valve with surge protection |
| 790-01 | pressure reducing valve, 790 series variant |
Where is Cla-Val equipment used?
- Drinking water supply - municipal networks and pumping stations
- Fire protection - hydrant and sprinkler systems
- Marine - fuelling and hydraulic systems on ships
- Aviation and rail - fuel supply systems for terminals
- Mining and industry - fluid control in process installations
How do we supply Cla-Val in Romania?
We bring in Cla-Val valves to order through EU supply channels, usually in 1–4 weeks for most current diameters. Availability is confirmed model by model - we work from the manufacturer's technical documentation, so we need the pipe diameter, the working pressure and the function required (pressure reduction, level control or flow control) to identify the correct variant. Availability of each diameter in the range is checked in the quotation.
Lead times for large diameters or specially cast variants depend on the schedule of the factory in the USA and are given in the quotation.
Frequently asked questions about Cla-Val
What is the difference between the Cla-Val 90-01 and 90-01KO models?
The 90-01 model is the standard pressure reducing valve, used to maintain a constant downstream pressure regardless of flow variations or upstream pressure. The 90-01KO variant adds anti-cavitation protection, recommended where a large difference between inlet and outlet pressure could cause noise or internal erosion of the valve.
How do I choose the right Cla-Val pressure reducing valve for a water network?
Selection starts from the maximum flow of the network, the inlet pressure and the desired downstream pressure; for installations with large flow variations, variants with a bypass can be used, such as 90-48 or 90-99. The pipe diameter, the valve material and whether the installation also needs an additional electric shut-off function, offered by the 93-01 series, also matter.
Which Cla-Val valve offers surge protection?
For protection against hydraulic surge, caused by sudden pump stops or fast valve closures, the models from the 94 series are indicated, such as 94-01, 94-22 or 94-58, which combine the pressure reducing function with limiting of pressure peaks. The choice of the exact variant depends on the estimated surge amplitude and on other functions needed in the installation.
Do you supply Cla-Val valves in Romania?
Yes, we bring in to order the pressure reducing, sustaining and control valves from the Cla-Val range described above, according to the data sheets published by the manufacturer for each model in the series. These valves are supplied to order, and the lead time is usually 1–4 weeks from order. For a quotation, send the pipe diameter, the working pressures and the maximum flow rate of the installation.
How do I request a Cla-Val quotation?
Send the Cla-Val code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 20 November 2026 · Sources: Cla-Val, Cla-Val Company (manufacturer documentation)