Dynamic Ratings supplier in Romania

Monitors for transformers, bushings and switchgear: C50, E3, DTM, B100

Headquarters: Sussex, USA

Request a quote

Who is Dynamic Ratings and what does it make?

Dynamic Ratings is a company with its global headquarters in Sussex, Wisconsin (USA), that makes monitors for transformers, bushings, circuit breakers and medium-voltage switchgear. For a substation engineer, the interesting part is that the instruments do not sit in a laboratory, but on the transformer in the substation, continuously calculating temperature, loading and insulation condition.

The transformer range includes B100 (electronic temperature monitor, replacing classic thermometers), C50 (modular monitor for bushings, DGA, partial discharge, tap changer and cooling), E3 (monitor with thermal models, loading calculations, cooling control and harmonics analysis, with 48–275 VDC or 60–265 VAC supply and an operating temperature from −40 to 80 °C) and DTM, a bushing condition monitor that tracks capacitance, power factor and partial discharges. C50 communicates over IEC 61850, DNP3 and Modbus. There are also hydrogen and moisture sensors, a tap position sensor, a rotating machine monitor (RMM) and monitors for circuit breakers and switchgear.

Such instruments interest substation operators who want to move from periodic inspections to continuous monitoring of large transformers, as well as heavy industry. For a quotation, what matters is the type and rating of the transformer, whether the bushings have test taps, the SCADA protocol and which sensors are fitted. The system must be fitted with the inputs suited to the unit.

What do we supply from the Dynamic Ratings range?

ProductDescription
C50 — transformer and bushing monitorModular transformer monitor, with bushing monitoring (sum-of-currents method and reference-voltage method), DGA, partial discharge, tap changer and cooling. Protocols: IEC 61850, DNP3, Modbus.
E3 — transformer monitorMonitor for bushings, windings, OLTC, cooling and insulation, with predictive thermal models and harmonics analysis. Mounting on a 35 mm DIN rail, operating temperature between −40 and 80 °C.
DTM — bushing condition monitorMonitor for bushing condition: capacitance and power factor in real time, partial discharges in the transformer, bushing and isolated-phase bus, with up to two bushing modules and two partial discharge modules.
B100 and hydrogen and moisture sensorsB100 is an electronic temperature monitor for transformers. The sensors measure hydrogen, moisture, pressure and temperature and integrate with B100 and with SCADA.

Why Dynamic Ratings?

  • DTM bushing monitor — tracks the capacitance and power factor of each bushing, with an alarm on the magnitude and trend of the current imbalance
  • C50 with IEC 61850, DNP3 and Modbus — can be integrated into an existing SCADA and can take data from DGA instruments of other makes
  • E3 with thermal models and cooling control — dynamic loading calculations, multiple cooling control groups and fault counting
  • Combined hydrogen, moisture, pressure and temperature sensor — no calibration or carrier gases and no scheduled maintenance, suited to transformer fleets
  • Monitors for several types of equipment — transformers, bushings, circuit breakers, MV switchgear and rotating machines — from the same manufacturer

Which Dynamic Ratings codes and series are requested most often?

CodeDescription
B100Electronic temperature monitor for transformers
C50Transformer monitor, modular
C50 Bushing MonitorBushing monitoring module for C50
E3Transformer monitor with thermal models and cooling control
DTMBushing condition monitor
VaultSafeVaultSafe transformer monitor
T3 (DRMCC)T3 monitor with cooling control
BAU+Bushing sensor
RMMRotating machine monitor, with partial discharge
SWGMMonitor for MV switchgear
SCMMonitor for switchgear and cables
iBridgeCommunications solution

Where is Dynamic Ratings equipment used?

  • Substations — continuous monitoring of power transformers
  • Power plants — step-up transformers and rotating machines (RMM)
  • Heavy industry — process transformers where a shutdown must be avoided
  • Predictive maintenance — analysis of bushings and the cooling system
  • Distribution transformer fleets — hydrogen and moisture sensors

How do we supply Dynamic Ratings in Romania?

For Dynamic Ratings monitors you can request a quotation by sending the type, rating and voltage of the transformer, whether the bushings have test taps, the cooling type, the tap changer, the SCADA protocol and the sensors you want (hydrogen, DGA, tap position). We supply to order; the system is configured to the unit, so the lead time can be longer, depending on the specification, and is confirmed in the quotation. For checking, the transformer control diagram and photos of the existing taps help.

Compatibility with the bushing test taps or with an existing SCADA is established on the basis of the transformer datasheet; installation and configuration are outside our offer.

Frequently asked questions about Dynamic Ratings

What product range does Dynamic Ratings have?

Monitors for transformers (B100, C50, E3, DTM, VaultSafe, T3), hydrogen, moisture and tap position sensors, monitors for circuit breakers, MV switchgear and rotating machines, plus the iBridge communications solution. The global headquarters is in Sussex, Wisconsin.

How do I choose between C50, E3 and DTM?

C50 is a modular system, with bushing monitoring and IEC 61850, DNP3 and Modbus protocols. E3 emphasises thermal models, loading and cooling control. DTM focuses on bushing condition. Send the transformer datasheet and what you want to monitor.

Can you supply Dynamic Ratings monitors in Romania, and in what lead time?

Dynamic Ratings instruments are supplied to order, usually in 1–4 weeks; the configuration for the transformer can extend the lead time, and the specific lead time is given in the quotation.

Can I fit a bushing monitor on an existing transformer?

It depends on the type of bushings, whether test taps exist and the sensors used. For checking we need the bushing nameplate, the transformer datasheet and photos of the taps; we confirm compatibility only on the basis of this data.

What details should I give for a quotation on an E3 monitor?

The type and rating of the transformer, the cooling system and the number of fan or pump groups, the inputs needed (digital, analogue, voltage), the available supply and the communication you want. With this data we check the configuration before the quotation.

How do I request a Dynamic Ratings quotation?

Send the Dynamic Ratings code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.