Dynisco supplier in Romania
For Dynisco we quote Echo, Guardian and PT460 melt pressure transducers, SPX and MDT transmitters, ATC990 and UPR900 instruments, LMI indexers and LCR rheometers; for a quotation we need the code from the sensor, the pressure range and the output signal.
Headquarters: Franklin, Massachusetts, USA
Who is Dynisco and what does it make?
Dynisco is an American manufacturer based in Franklin, Massachusetts, of melt pressure sensors, process instruments and laboratory instruments for evaluating polymers. On extrusion, injection and blow moulding lines, the pressure of the plastic melt is measured with diaphragm transducers with fill fluid, able to withstand high temperatures and pressures; the signal feeds indicators, controllers and the line's control system.
The sensor range has two families. The melt pressure transducers, with a 3.33 mV/V output, include the Echo, Guardian, DYN-X, MDA420, MDA460, PT450, PT460, PT467 and MRT462 series. Echo covers ranges from 1,500 to 10,000 psi, with an accuracy better than ±0.5 %, repeatability of ±0.2 %, a TiAlN-coated diaphragm and an output in mV/V, 0–10 V or mA. The transmitters include SPX 2, 3, 4 and 5, MDT and PT46X4, PT46X5, PT46X6; SPX 4-Series gives a 4–20 mA signal, with an accuracy of ±0.25 %, HART, versions for areas with explosion risk and with functional safety on the pressure output, according to the manufacturer's documentation. For injection moulding there are the PT465XL and PT467XL series.
The panel instruments include the UPR900, 1480 and 1490 indicators, the ATC990 pressure controller (Modbus RS-485 and Ethernet TCP) and the 1496 and 1498 temperature controllers. In the laboratory, the LMI5500 and LMI6000 melt flow indexers measure the melt flow rate (LMI5500 complies with ASTM D1238 and ISO 1133), the LCR7000 capillary rheometer reaches 430 °C, and the LME, TUS and LEC benchtop extruders prepare small polymer batches.
What do we supply from the Dynisco range?
| Product | Description |
|---|---|
| Melt pressure transducers | Echo, Guardian, DYN-X, DYN-X-MA, DYN-X-V, MDA420, MDA460, PT450, PT460, PT420A, PT467E-M10, PT462E-M10, PT460XL, MRT462 and MRT463 series, with a 3.33 mV/V output, for extrusion and polymer processing. Echo covers ranges from 1,500 up to 10,000 psi. |
| Melt pressure transmitters | SPX 2-Series, SPX-T (series 3), SPX 4-Series, SPX 5-Series, MDT, PT46X4, PT46X5 and PT46X6, with a 4–20 mA signal. SPX 4-Series (SPX4222, SPX4622, SPX4352, SPX4672, SPX4232, SPX4502) has an accuracy of ±0.25 %, HART and versions with functional safety. |
| Injection moulding sensors and panel instruments | PT4654XL, PT4655XL, PT4656XL, PT465XL, PT467XL, PT4674, PT4675 and PT4676 for injection moulding; the UPR900, 1480 and 1490 indicators; the ATC990 controller and the 1496 and 1498 temperature controllers, configurable with the BlueControl software. |
| Laboratory instruments for polymers | LMI5500 and LMI6000 melt flow indexers, the LCR7000 capillary rheometer with multi-zone heating, up to 430 °C, and the LME, TUS and LEC benchtop extruders. LMI5500 complies with ASTM D1238 and D3364, ISO 1133-1 and 1133-2, BS 2782, DIN 53735 and JIS K7210. |
Why Dynisco?
- mV/V melt transducers (Echo, Guardian, DYN-X, PT460) and transmitters (SPX, MDT, PT46X) — the same range covers lines with a strain gauge input and lines with a current loop
- Echo with accuracy better than ±0.5 % and a TiAlN-coated diaphragm — for general extrusion, with optional NaK (sodium-potassium alloy) fill fluid
- SPX 4-Series with HART, ATEX versions according to the manufacturer's documentation and with functional safety on pressure — a transmitter for hazardous areas and safety loops
- LMI5500 and LMI6000 for melt flow index, to ASTM D1238 and ISO 1133 — flow rate, viscosity and melt density in a single instrument
- UPR900, 1480, 1490, ATC990 and 1496/1498 panel instruments — display, pressure and temperature control in the same ¼ DIN housing type
Which Dynisco codes and series are requested most often?
| Code | Description |
|---|---|
| Echo Series | mV/V melt transducer, up to 10,000 psi, TiAlN coating |
| Guardian Series | mV/V melt pressure transducer |
| DYN-X Series | mV/V melt pressure transducer |
| PT460 Series | mV/V melt pressure transducer |
| PT460XL | mV/V melt pressure transducer, XL version |
| MRT462 | mV/V melt pressure transducer |
| SPX 2-Series | Melt pressure transmitter, 4–20 mA |
| SPX 4-Series | Transmitter ±0.25 %, HART, versions for areas with explosion risk and with functional safety |
| SPX 5-Series | Melt pressure transmitter |
| MDT Series | Melt pressure transmitter |
| PT465XL | Injection moulding sensor, 0.5 %, mV/V |
| PT4674 | Injection moulding sensor, 0.5 %, 4–20 mA |
| ATC990 | Differential pressure controller, Modbus and Ethernet |
| UPR900 | Process indicator for strain gauge sensors |
| LMI5500 | Melt flow indexer, ASTM D1238, ISO 1133 |
| LCR7000 | Capillary rheometer, up to 430 °C |
Where is Dynisco equipment used?
- Plastics extrusion — melt pressure at the extruder head, in pipe, film and profile lines
- Injection moulding — PT465XL, PT467XL and PT4674 sensors for injection moulding
- Blow moulding — measuring melt pressure in blow moulding installations
- Plastics recycling — measuring melt pressure in recycling lines
- Polymer quality control laboratories — melt flow index and capillary rheology
How do we supply Dynisco in Romania?
We can quote Dynisco melt pressure sensors, both the mV/V transducers (Echo, Guardian, PT460, DYN-X) and the 4–20 mA transmitters (SPX, MDT, PT46X), the ATC990, UPR900, 1480 and 1490 instruments, and the LMI and LCR instruments. Dynisco orders are usually fulfilled in 1–4 weeks, and depending on the specification the lead time may be longer, which is confirmed in the quotation. For an accurate request, send the full code from the existing sensor, the pressure range, the output signal, the stem length and the thread, or the type of laboratory instrument.
The equivalence of the thread, the stem length or the fill fluid for an old sensor is established from the full code on its nameplate.
Frequently asked questions about Dynisco
What does Dynisco make?
Dynisco makes melt pressure sensors (mV/V transducers and 4–20 mA transmitters), process instruments such as the UPR900 indicators and the ATC990 controller, LMI melt flow indexers, LCR7000 capillary rheometers and benchtop extruders for polymer laboratories.
How do I choose between an mV/V transducer and a 4–20 mA transmitter?
The transducer (Echo, PT460, Guardian) gives 3.33 mV/V and connects to an indicator or amplifier, while the SPX transmitter gives 4–20 mA directly to the PLC or DCS, with HART on the SPX 4. The choice depends on the instrument input. Tell us the signal required.
Do you supply Dynisco sensors in Romania, and how quickly?
Yes, to order: Dynisco usually arrives in 1–4 weeks. Depending on the specification, the lead time may be longer, especially for stem lengths or special ranges; the date is confirmed in the quotation.
What replaces an old Dynisco sensor on an existing line?
A replacement is checked on the full code from the sensor: series, pressure range, signal, stem length, thread and fill fluid. We confirm a replacement on the basis of this data. Send us the code and a photo of the nameplate, so that we can check which current series fits.
What data do I need to send for a quotation on a melt flow indexer or rheometer?
Send the polymer and the test standard (ASTM D1238 or ISO 1133), the working temperature and load, whether you are tracking only the flow rate or also capillary rheology, and the software or network the instrument must communicate with.
How do I request a Dynisco quotation?
Send the Dynisco code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Dynisco (manufacturer documentation)