E.L.B. Füllstandsgeräte supplier in Romania
For E.L.B. Füllstandsgeräte we quote T200.F overfill protection, EF2 electrodes, ELH leak detection probes, QFS float switches and TK-300 transmitters; we need the type, probe length, material, supply voltage and Ex zone.
Founded in 1980 · Headquarters: Zwingenberg, Germany
Who is E.L.B. Füllstandsgeräte and what does it make?
E.L.B. Füllstandsgeräte is a German brand of instruments for measuring and monitoring liquid levels, founded in 1980 and based in Bensheim since 1985. The products are developed and manufactured in Germany and are used for detecting, recording and controlling level in industrial tanks. Since 2023 the company that makes the E.L.B. instruments has been named Fluid.iO Sensor + Control, while the instrument types, such as T200.F or EF2, have remained the same. For a quotation, send us the type from the instrument, for example T200.F, EF2 or QFS-2X, plus the probe length and the supply voltage.
The core programme includes overfill protection and leak detection probes with WHG conformity marking (Wasserhaushaltsgesetz, the German water resources act), together with evaluation electronics. Overfill protection is built with conductive electrodes, such as EF2 and the adjustable EFV2, with magnetic float probes from the T200 series or with KF25 capacitive sensors, while leaks in containment bunds are detected with ELH suspended electrodes, EP plate electrodes or KL25 probes. Many variants are intended for explosive atmosphere zones: EE-2XF, T204.F and T209-0.F for category 1 (zone 0), T-200.L Ex for category 2 (zone 1).
For limit level signalling there are mercury-free float switches from the QFS and QFSK series, PTFE variants for liquids up to 150 °C, the NSP-X-E vibrating switch, KG-2XX capacitive switches and NP-255 pneumatic switches for aggressive or sticky liquids. Continuous level is measured with HD-100 hydrostatic probes, LU-150 and LU-180 EX ultrasonic transmitters or TK-300 series magnetic float transmitters, including the TK-307 for bypass chambers. The range is found in fuel depots, chemical stations and water treatment plants.
What do we supply from the E.L.B. Füllstandsgeräte range?
| Product | Description |
|---|---|
| T200 overfill protection and EF2 electrodes | T200.F, T203.F and T204.F magnetic float probes, EF2, EF2…5 and adjustable EFV2 conductive electrodes and the KF25 capacitive sensor, with evaluation electronics, used as overfill protection for tanks; the T204.F and EE-2XF variants work in zone 0. |
| ELH, EP, KL25 and T-200.L leak detection probes | ELH suspended electrodes, EP plate electrodes, the KL25 capacitive probe and T-200.L probes, including the T-200.L Ex for zone 1, which signal liquid that has leaked into bunds and containment rooms or into inspection and filling manholes; for double-wall pipes there is the EF2X electrode. |
| QFS, NSP and KG level switches | QFS-1X mercury-free float switches, QFS-2X with a stainless steel float and QFS-5x in PTFE, QFSK combinations with minimum and maximum contacts, the NSP-X-E vibrating switch and KG-2XX capacitive switches for liquids and solids. |
| HD, LU and TK continuous level transmitters | HD-100 submersible and HD-110 threaded hydrostatic probes with 4–20 mA output, LU-150 and LU-180 EX compact ultrasonic transmitters, IP68, and TK-300 to TK-309 magnetic float transmitters, including the stainless steel TK-307 for bypass chambers. |
Why E.L.B. Füllstandsgeräte?
- Overfill protection and leak detection probes with WHG marking — for tanks holding liquids hazardous to water
- Variants for zone 0 and zone 1 (ATEX) — EE-2XF, T204.F and T-200.L Ex for tanks with an explosive atmosphere
- QFS mercury-free float switches — stainless steel or PTFE variants, for liquids up to 150 °C
- Continuous measurement on three principles — hydrostatic HD-100, ultrasonic LU-150 and magnetic float TK-300
- Versions in PVC, PE, PP, PTFE and stainless steel — float probes are chosen according to the chemical compatibility of the liquid
Which E.L.B. Füllstandsgeräte codes and series are requested most often?
| Code | Description |
|---|---|
| T200.F | Magnetic float overfill protection for tanks |
| T204.F | Magnetic float probe for zone 0 (category 1) |
| EF2 | Conductive electrode for overfill protection |
| EFV2 | Adjustable conductive electrode with direct supply |
| EE-2XF | Conductive electrodes for overfill protection in Ex zone 0 |
| KF25 | Capacitive level sensor for overfill protection |
| ELH | Suspended electrode used as a leak detection probe |
| T-200.L Ex | Leak detection probe for Ex zone 1 (category 2) |
| QFS-2X | Stainless steel float switch, mercury-free |
| QFS-5x | PTFE float switch, liquids up to 150 °C |
| NSP-X-E | Vibrating level switch for liquids |
| KG-2XX | Capacitive level switch for liquids and solids |
| HD-100 | Submersible hydrostatic probe, 4–20 mA, IP68 |
| LU-150 | Compact ultrasonic level transmitter, 4–20 mA, IP68 |
| TK-307 | Stainless steel level transmitter for bypass chamber |
Where is E.L.B. Füllstandsgeräte equipment used?
- Fuel and oil depots — T200.F overfill protection with WHG marking
- Chemical industry — PTFE and PP probes, NP-25X pneumatic switches for aggressive liquids
- Water treatment and sewerage — HD-100 hydrostatic probes and HE suspended electrodes in basins and manholes
- Installations in Ex zones — T204.F and EE-2XF probes for zone 0
- Containment bunds and double pipes — ELH, EP and EF2X leak detection probes
How do we supply E.L.B. Füllstandsgeräte in Romania?
We quote E.L.B. level instruments: overfill protection, leak detection probes, conductive electrodes, float and vibrating switches and continuous level transmitters. To identify the instrument correctly, send us the complete type from the label, the length of the probe or rod, the material (PVC, PP, PTFE, stainless steel), the supply voltage, the liquid in the tank and, where applicable, the Ex zone. We bring them in on order, usually 1–4 weeks; an item that is in stock, locally or at the supplier, can ship in 24–72 h. For probes with special lengths the lead time may be longer.
We supply E.L.B. instruments as new items; the functional test of the overfill protection after installation and any periodic checks required by the authorities remain the responsibility of the tank operator.
Frequently asked questions about E.L.B. Füllstandsgeräte
What level instruments does E.L.B. Füllstandsgeräte make?
E.L.B. makes level instruments for liquids in Germany: overfill protection and leak detection probes with WHG marking, conductive electrodes, float, vibrating, capacitive and pneumatic switches, mechanical indicators and continuous level transmitters of the hydrostatic, ultrasonic and magnetic float types.
Which E.L.B. probe suits overfill protection of a diesel tank?
For non-conductive liquids such as diesel, magnetic float probes from the T200 series are usually used, not conductive electrodes; KF25 capacitive sensors are intended for non-combustible liquids. Send us the tank height, the connection type, the material you want and whether the zone is classified Ex, and we propose the suitable type.
How quickly do you bring an E.L.B. probe to Romania?
An E.L.B. probe that is in stock, locally or at the supplier, can ship in 24–72 h. Otherwise we bring it in on order, usually 1–4 weeks. For special lengths or materials, depending on the brand and the specifications, the lead time may be longer; we state it in the quotation.
We have an old E.L.B. probe with an illegible label. Can you replace it?
Yes, if you help us identify it: photos of the probe and of the evaluation box, the rod length, the number of electrodes or contacts, the material and the supply voltage. Based on these data we look for the current equivalent type in the E.L.B. range and propose it in the quotation.
What information do I send for a quotation on E.L.B. continuous level transmitters?
The principle you want (hydrostatic HD, ultrasonic LU or magnetic float TK), the measuring range, the liquid and its temperature, the process connection, the output (4–20 mA) and, if the tank is in an Ex zone, the required category, for example LU-180 EX or TK-303 for zone 0.
How do I request a E.L.B. Füllstandsgeräte quotation?
Send the E.L.B. Füllstandsgeräte code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: E.L.B. Füllstandsgeräte, Fluid.iO Sensor + Control (manufacturer documentation)