Elicent supplier in Romania
For Elicent we quote extraction fans from the IC INOX, PDL INOX, HT INOX, PF AT and S-CUBE P KAT series, ATEX fans and fans for animal housing; the item is determined by the flow rate, the pressure and the medium handled.
Headquarters: Lonato del Garda, Italy
Who is Elicent and what does it make?
Elicent is an Italian brand of extraction fans, headquartered at Lonato del Garda, in the province of Brescia. The industrial range includes propeller fans with direct discharge, centrifugal fans with duct discharge, roof fans and air-circulation fans, for which the air temperature is limited to 50 °C. Alongside them are fans for explosive atmospheres, for acid environments, for high temperatures and for fire-safety ventilation.
The ATEX range includes axial fans, roof fans, in-line fans, centrifugal fans with forward-curved blades, centrifugal fans with backward-curved blades and cabinet-type fans. They are for gases, hydrogen and dusts, in zones 1 and 2 for gases and 21 and 22 for dusts, with a minimum temperature class T4 and gas groups IIA, IIB and IIB+H2. The EN 14986 standard and Directive 2014/34/EU apply, and the applications indicated are refineries, biomass plants and sawmills.
For corrosive environments there are seven series: IC INOX, PR AC, ICA, TCA, PDL INOX, PF INOX and HT INOX; the last three are professional in-line centrifugal fans, for clean air at low-medium pressure, for smoke with dust and for high pressure. For high temperatures there are the series PR-QP AT, TCF A.T., IC A.T., PDL AT, PF AT and HT AT, and S-CUBE P KAT is for industrial kitchens, up to 180 °C. For animal housing there are Super POLAR HVLS, POLAR ZOO, ECO ZOO 1400 and ZOO.
What do we supply from the Elicent range?
| Product | Description |
|---|---|
| ATEX fans | Axial fans, roof fans, in-line fans, centrifugal fans with forward-curved or backward-curved blades and cabinet-type fans, for gases, hydrogen and dusts in zones 1, 2, 21 and 22, with a minimum temperature class T4. |
| Anticorrosive and acid-resistant fans | IC INOX, PDL INOX, PF INOX and HT INOX are in-line centrifugal fans, in the INOX version; PR AC and ICA are acid-resistant, and TCA is for the roof. PDL, PF and HT differ in the air handled and the pressure. |
| Fans for high temperatures | PR-QP AT has a square casing and backward-curved blades, TCF A.T. is a roof fan with a single speed, IC A.T. is in-line, and PDL AT, PF AT and HT AT are professional fans. S-CUBE P KAT works up to 180 °C. |
| Fans for livestock and fire safety | Super POLAR HVLS is a destratifier, POLAR ZOO Back 1300 is mounted on a wall or ceiling, and Rack 2500 on a wall; ECO ZOO 1400 and ZOO are axial. The fire-safety range includes smoke extraction, car park ventilation and stairwell pressurisation. |
Why Elicent?
- ATEX range for gases, hydrogen and dusts — the choice takes into account the zone, the temperature class and the gas group in the installation
- Seven series for corrosive and acid environments — the choice is made according to the nature of the vapours handled
- Series marked AT for high temperatures — roof, in-line or with a square casing
- S-CUBE P KAT series, with an EC version — ventilation of industrial kitchens up to 180 °C
- Fans for animal housing, from HVLS destratifiers (high volume, low speed) to belt-driven axial extractors — they also cover the agricultural area
Which Elicent codes and series are requested most often?
| Code | Description |
|---|---|
| IC INOX | Anticorrosive in-line centrifugal fan |
| PR AC | Acid-resistant centrifugal fan with round inlet |
| ICA | Acid-resistant in-line centrifugal fan |
| TCA | Acid-resistant centrifugal roof fan |
| PDL INOX | Professional in-line fan for clean air, low-medium pressure |
| PF INOX | Professional in-line fan for smoke with dust |
| HT INOX | Professional in-line fan for high pressure |
| PR-QP AT | Centrifugal fan with square casing, for high temperatures |
| TCF A.T. | Centrifugal roof fan, single speed, high temperatures |
| IC A.T. | In-line centrifugal fan, high temperatures |
| PF AT | Professional fan for smoke with dust, high temperatures |
| S-CUBE P KAT | Cabinet with backward-curved blades for industrial kitchens, up to 180 °C |
| S-CUBE P KAT EC | EC motor version of the S-CUBE P KAT cabinet |
| Super POLAR HVLS | Destratifier for animal housing |
| ECO ZOO 1400 | Axial fan for large spaces |
Where is Elicent equipment used?
- Refineries and chemicals — ATEX fans for gases and hydrogen in classified zones
- Biomass and woodworking — ATEX fans for dusts in zones 21 and 22
- Installations with acid or corrosive vapours — acid-resistant and INOX fans
- Industrial kitchens — S-CUBE P KAT cabinets, with an EC version
- Livestock — ventilation and destratification in large housing
How do we supply Elicent in Romania?
We quote Elicent fans for industrial extraction, ATEX environments, corrosive environments, high temperatures and animal housing. For a correct request, send the series or the name from the nameplate, the flow rate, the pressure, the temperature and the nature of the air handled; for ATEX add the zone, the gas or dust group and the temperature class. We supply to order, usually in 1–4 weeks; for special versions, depending on the specification, the lead time may be longer. The exact version is checked before confirmation.
For ATEX applications, the required classification is checked in the quotation before the series is confirmed, since each fan is approved for specific zones and groups.
Frequently asked questions about Elicent
What kind of fans does Elicent make?
Elicent has industrial extraction fans — propeller, centrifugal, roof and air-circulation fans —, ATEX fans, anticorrosive fans, fans for high temperatures, for fire-safety ventilation and for animal housing. The headquarters is at Lonato del Garda, in Italy.
What data do I give for an ATEX fan?
For ATEX, send the zone (1, 2 or 21, 22), the nature of the medium — gas, hydrogen or dust —, the gas group IIA, IIB or IIB+H2, the temperature class needed, the flow rate and the pressure. With these data we check the series with the suitable approval, since the range is certified by zone.
What is the difference between PDL, PF and HT in the INOX series?
PDL is a professional in-line fan for clean air at low-medium pressure, PF is for smoke with dust, and HT is for high pressure. All three exist in the INOX version, and the AT series works at high temperatures. Send the flow rate, the pressure and the nature of the air so that the series can be determined.
How do I order an Elicent fan and when does it arrive?
Send the series or type, the flow rate, the pressure, the voltage and the medium handled. We supply to order, usually in 1–4 weeks; it can ship in 24–72 h when the item is in stock, locally or at the supplier. The exact lead time appears in the quotation.
Can I find a fan for an animal housing?
Yes. The livestock range includes the Super POLAR HVLS destratifier, the POLAR ZOO Back 1300 wall or ceiling fan, the Rack 2500 wall-mounted fan, the ECO ZOO 1400 axial fan and the ZOO belt-driven axial extractor. Send the area of the housing, the number of existing fans and the available voltage.
How do I request a Elicent quotation?
Send the Elicent code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Elicent (manufacturer documentation)