For Fantini Cosmi we quote thermostats from the C and TG series, pressure switches B01, B12 and B13, level switches AD and A, solenoid valves M20, M23, M29 with IM2 coils; the item is identified by the complete code, the setting range and the voltage.

Headquarters: Caleppio di Settala, Italy

Request a quote

Who is Fantini Cosmi and what does it make?

Fantini Cosmi S.p.A. is based in Caleppio di Settala, near Milan, in Italy. It makes control and protection devices for industrial installations and for OEM equipment: thermostats, pressure switches, level switches, flow controls, solenoid valves and heating cables. Their role is simple: an electrical contact closes or opens at a set temperature, pressure or liquid level, and the installation starts, stops or goes into safety mode.

On the temperature side, the C series includes capillary-and-bulb thermostats for remote mounting, including the C04..Y version with IP65 protection, the C03 and C08 immersion thermostats and the C06 immersion thermostat with positive safety lock. The TG200 and TG300 series are control thermostats, while TG400 and TG500 are temperature limiters, some with manual reset and fail-safe function. For pressure, B01 covers up to 15 bar, B12CN–B12EN up to 28 bar, B12FN–B12HN up to 300 bar, and B12AN–B12BN work in vacuum, down to −0.82 bar. B70A and B71A directly control three-phase and two-phase motors, respectively.

For level there are magnetic switches AD22, AD23 and AD52 for pressure vessels, electronic controls A03 and A04 with probes for conductive liquids, submersible floats A94, A95 and A96, and controls for powders and granules ASE and ASM2. The solenoid valves M20, M23 and M29 are completed with IM2 coils. For a correct quotation, the complete code on the device, the setting range, the differential and the voltage matter.

What do we supply from the Fantini Cosmi range?

ProductDescription
C and TG series thermostatsCapillary-and-bulb thermostats C04 and C10, immersion C03, C06, C07 and C08, pipe-mounted C01, and control or limiting thermostats TG200, TG300, TG400 and TG500. The version is chosen according to the temperature range, the type of mounting and the need for manual reset.
Pressure switches B01, B12 and B13Pressure switches with adjustable or fixed differential: B01 up to 15 bar, B12CN–B12EN up to 28 bar, B12FN–B12HN up to 300 bar, B13BN–B13CN up to 10 bar, B11AN for pressures below 1 bar. There are also safety versions with manual reset, B01..M and B12MN.
Level switches and controlsMagnetic switches AD22 (up to 6 bar), AD23 (6/16 bar) and AD52 (up to 10 bar), electronic controls A03 and A04 with probes for conductive liquids, submersible floats A94, A95 and A96, paddle ASE and diaphragm ASM2 for dust and granules.
Solenoid valves M20, M23 and M29M20 is a direct-acting, normally closed solenoid valve body. M23 and M29 are servo-assisted diaphragm bodies, normally closed and normally open respectively. The IM2 series control coils are chosen according to the voltage and the type of body.

Why Fantini Cosmi?

  • Capillary, immersion and contact thermostats in the same C series — the measuring principle is chosen according to where the bulb can be mounted
  • TG400 limiters with manual reset and safety function — for circuits where a temperature overrun must stop the installation
  • Pressure switches from vacuum (−0.82 bar) up to 300 bar in the B12 series — the same type of device covers suction lines, water circuits and high-pressure circuits
  • Level controls for liquids, powders and granules — from submersible floats to paddles and diaphragms, depending on the medium in the tank
  • Direct-acting and servo-assisted solenoid valves, normally closed or normally open — the bodies are ordered separately from the IM2 coils

Which Fantini Cosmi codes and series are requested most often?

CodeDescription
C04Capillary-and-bulb thermostat for remote mounting; the C04..Y version has IP65
C06Immersion thermostat with positive safety lock
C10Thermostat with coiled capillary for industrial ambient conditions
TG400Temperature limiter, in manual or automatic reset versions, with or without safety function
B01Pressure switch up to 15 bar, with non-adjustable differential
B12CN–B12ENPressure switch up to 28 bar, with adjustable differential
B12FN–B12HNPressure switch up to 300 bar, with adjustable differential
B12AN–B12BNVacuum pressure switch, down to −0.82 bar
AD52Magnetic level switch for pressurised systems, up to 10 bar
A94Submersible electromechanical level control for wastewater
M20Direct-acting solenoid valve body, normally closed
M23Servo-assisted diaphragm solenoid valve body, normally closed

Where is Fantini Cosmi equipment used?

  • Heating plants and industrial boilers — control thermostats, limiters and safety pressure switches
  • Pumping stations and booster sets — B12 pressure switches and level switches for motor control
  • Process tanks and basins — level controls for liquids, powders and granules
  • Refrigeration and air-conditioning installations — vacuum and pressure switches, contact thermostats
  • OEM equipment — thermostats, pressure switches and solenoid valves built into series-produced machines

How do we supply Fantini Cosmi in Romania?

We can quote Fantini Cosmi thermostats, pressure switches, level controls and solenoid valves for new installations or to replace an existing device. For a quotation, send the complete code from the device, for example B12FN or C04, the setting range, the differential, the supply voltage and, for level, the liquid or material in the tank. For solenoid valves we also need the connection diameter and the working pressure. We bring the devices to order, usually in 1–4 weeks, and items can ship in 24–72 h when the item is in stock, locally or at the supplier. We confirm the exact lead time in the quotation.

Before the quotation we check the complete code of the device, because two pressure switches from the same series can differ in setting range and in differential.

Frequently asked questions about Fantini Cosmi

What families of devices does Fantini Cosmi make for industrial installations?

Fantini Cosmi, from Caleppio di Settala, makes thermostats, pressure switches, level and flow controls, solenoid valves and heating cables. The usual series are C and TG for temperature, B01, B12 and B13 for pressure, AD and A for level and M20, M23 and M29 for solenoid valves.

How do I choose between a B12CN and a B12FN pressure switch?

The main difference is the pressure range. B12CN–B12EN work up to 28 bar and B12FN–B12HN up to 300 bar, both with adjustable differential. Send the working pressure and the maximum trip pressure, and we determine the variant that goes into the quotation.

Can I replace a C04 capillary thermostat with another model?

Yes, if you keep the type of mounting, the capillary length, the temperature range and the protection rating. The C04 series also exists in the C04..Y version with IP65. Send the code from the device, and we check whether the requested item exists in the Fantini Cosmi range.

Do you bring Fantini Cosmi devices to Romania and how soon?

Yes. The request is fulfilled with a usual lead time between one and four weeks. Items can ship in 24–72 h when the item is in stock, locally or at the supplier. Devices with a special configuration may take longer; you receive the exact lead time in the quotation.

What details should I give for an AD22, AD23, AD52 or A94 level control?

The series or code from the device, the liquid or material being controlled, the pressure in the tank and the control voltage. The AD22, AD23 and AD52 controls are for pressure vessels, A94, A95 and A96 are submersible floats, and ASE and ASM2 are for powders and granules.

How do I request a Fantini Cosmi quotation?

Send the Fantini Cosmi code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote