Keller supplier in Romania
For standard Keller 33X series transmitters we quote on the transmitter type code; availability and lead time are confirmed in the quotation.
Founded in 1974 · Headquarters: Winterthur, Switzerland
Who is Keller and what does it make?
Keller is a Swiss manufacturer of high-precision piezoresistive pressure transducers and transmitters. For 50 years it has been developing pressure sensors for industrial, hydrology, geotechnical, automotive and aerospace applications where accuracy, long-term stability and reliability are absolutely critical. The Winterthur factory exports transducers internationally, each individually calibrated and certified.
The manufacturer's technology is based on piezoresistive cells with a monocrystalline silicon diaphragm on which Wheatstone resistors are diffused. When pressure deforms the diaphragm by a few micrometres, the electrical resistance changes proportionally, generating an accurate and stable electrical signal. Temperature is compensated by resistors integrated on the same chip and digital compensation algorithms; on the 33X series the total error band is ±0.1 %FS over the -10…80 °C range, and the operating range is -40…125 °C.
Keller produces pressure transducers for ranges from 0.3 to 1000 bar (33X series), submersible level probes and dataloggers for monitoring. The exact ranges and battery life depend on the model and are confirmed from the Keller documentation.
What do we supply from the Keller range?
| Product | Description |
|---|---|
| 33X series standard transmitters | 33X standard transmitters measure pressures from 0…0.3 to 0…1000 bar, with an accuracy of ±0.05 %FS and RS485, 4…20 mA or 0…10 V outputs. For submersible level measurement in wells, boreholes, rivers and lakes, Keller level probes are used (for example the 36XW series). |
| 21/25/35Y series transmitters for industry | The industrial range covers pressures from 0-100 mbar to 0-1000 bar, absolute or gauge. A digitally compensated piezoresistive cell provides 0.05% or 0.1% FS accuracy, high stability and a response time under 1ms. Compact 316L stainless steel housing with G1/4", G1/2", NPT1/4" or flange connection. Versions with a flush diaphragm for viscous liquids, paste, powder. Supply 10-30VDC, output 4-20mA, 0-10V, 0-5V or RS485. Versions for zone 0/1 gas and dust, according to the manufacturer's documentation. Optional local LCD display and programming keys for field configuration without a PC. |
| ARC/DCX series wireless dataloggers | Keller dataloggers combine the pressure transducer with data recording; readout is through a connector or through remote transmission, depending on the system. Recording at a configurable interval from 1 minute to 24 hours, memory 10,000-50,000 records. Applications: aquifer level monitoring, water distribution pipeline pressure, deformation of dikes and dams, snow load on roofs. |
| PD-39X series differential transducers | They measure the pressure difference between two points - essential for filter monitoring, Venturi flowmeters, clean room control, HVAC systems. The differential pressure ranges, permitted static pressure, accuracy and compensated temperature range depend on the model and are confirmed from the Keller datasheet. Separate connections for high and low pressure, stainless steel or aluminium housing. Output 4-20mA, 0-10V or Modbus. Applications: ΔP across air/oil filters, Venturi flow, differential pressure control in ISO 5-8 clean rooms. |
Why Keller?
- 0.05% FS accuracy - high precision for critical applications
- Long-term stability specified in the datasheet of each model; the recalibration frequency is set per application
- Digital temperature compensation - total error band ±0.1 %FS over the -10…80 °C range (33X series)
- Versions with titanium or Hastelloy diaphragm for aggressive media; compatibility with the medium is checked per model
- Submersible level probes (for example the 36XW series), with depth ranges depending on the model
- Datalogger options with remote transmission; the technology, range and battery life depend on the model
Which Keller codes and series are requested most often?
| Code | Description |
|---|---|
| Series 33X | standard pressure transducer, range 0.3 to 1000 bar |
| Series 33X-Ed | pressure transducer with flameproof housing for classified areas |
| Series 35X | pressure transducer with flush diaphragm |
| Series 35HTCX | flush-diaphragm transducer for high temperatures |
| Series PD-33X | differential pressure transducer from the 33X family |
| Series PD-39X | differential pressure transducer for industrial applications |
| Series PD-39X-Ei | differential transducer with intrinsically safe certification |
| Series 21Y | compact pressure transducer for general use |
| Series 23 | pressure transducer from the Keller standard range |
| Series PD-23 | differential pressure transducer from the 23 range |
| Series 25 | miniature pressure transducer for installation in confined spaces |
| 22M/22S | miniature pressure transducers, M and S versions |
| Series 36XW | submersible level probe for water measurement |
| DCX-22 | autonomous level datalogger for groundwater and surface water |
Keller series with English pages
Where is Keller equipment used?
- Hydrology - level monitoring of aquifers, rivers, lakes and wells
- Water Supply - distribution networks, tanks, pumping stations
- Oil & Gas - production wells, transport pipelines, offshore platforms
- Geotechnical - monitoring of slope stability, tunnels, dams
- HVAC - pressure control, filters, fans, clean rooms
- Automotive - fuel, brake and suspension pressure tests
- Aerospace - altitude, airspeed and cabin pressure measurement
- Chemical - pressurised reactors, distillation, polymerisation
- Marine - ballast, seawater, naval hydraulic systems
- Environmental - pollution monitoring, water management
How do we supply Keller in Romania?
We source Keller pressure transducers from Winterthur to order, and availability is checked for each reference on request. Technical parameters are taken from the technical documentation of the Swiss manufacturer, and the specific lead time is confirmed after checking with the supplier. As a general rule, standard transducers can arrive in 24–72 h when the item is in stock, locally or at the supplier, while special submersible versions or wireless sets go through the order flow, usually 1–4 weeks. Send us the pressure range, the type of medium measured and the cable length required for a quick check. For accredited recalibration, the customer contacts the manufacturer's laboratory directly.
Availability of each Keller submersible version is checked on request; SAS-accredited calibration certificates are issued by accredited laboratories.
Frequently asked questions about Keller
How do I choose between the Keller 33X series and 21Y series transducers?
The 33X series covers a wide range, from 0.3 to 1000 bar, and offers high precision through digital compensation, making it suitable for demanding industrial measurements. The 21Y series is a compact solution for general use, with simpler installation where extreme precision is not the main requirement. The choice depends on the pressure range and the accuracy required by the application.
What pressure range and interfaces does the Keller Series 35X transmitter have?
The Series 35X is a front-flush pressure transmitter with ranges from 0…0.3 to 0…1000 bar. Accuracy is ±0.05 %FS and the total error band is ±0.1 %FS at -10…80 °C. Interfaces are RS485, 4…20 mA and 0…10 V, and the temperature range is -40…125 °C. We confirm the full code with the quotation.
What details should I send for a Keller transducer quotation?
Specify the pressure range needed, the type of medium measured, the operating temperature, the electrical output type (4-20 mA, RS485 or voltage) and whether certification for explosive areas is needed. If you are replacing an existing transducer, the complete code on its label speeds up identification of the equivalent version in the current range.
What is a differential transducer such as the Keller Series PD-39X?
A differential transducer measures the pressure difference between two points of an installation, useful for clogged filters, flowmeters or level in closed tanks. The PD-39X series is designed for demanding industrial applications, and the PD-39X-Ei version adds intrinsically safe certification for explosion-risk areas. Correct selection takes into account the differential range and the working medium.
How do I request a Keller quotation?
Send the Keller code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Keller Pressure, Keller AG für Druckmesstechnik (manufacturer documentation)