Layne Bowler supplier in Romania
For Layne Bowler we quote vertical shaft, axial flow, submersible, horizontal and vertical multistage, standardised single-stage, double-suction SP and Sew Line wastewater pumps; we need the flow rate, the head and the liquid pumped.
Headquarters: Ankara, Turkey
Who is Layne Bowler and what does it make?
Layne Bowler, based in Ankara, Turkey, offers pumps for water, wastewater and geothermal water. The range covers vertical turbine pumps, axial flow pumps, submersible pumps, horizontal and vertical multistage pumps, standardised single-stage pumps, SP double-suction split-casing pumps, Sew Line series wastewater pumps and geothermal pumps, plus pump and system engineering services.
Vertical shaft pumps are intended for deep wells and for water levels too low for other pump types. Axial flow pumps handle large flow rates at low heads, for example when draining flood water. Horizontal multistage pumps have a closed impeller and diffusers, with nominal diameters from DN 32 to DN 200, in 9 models, and single-stage end-suction pumps have dimensions conforming to DIN 24255 / EN 733. SP pumps run with a horizontal shaft, a split casing and double suction, and are also available in versions with a vertical shaft or a double volute for higher pressures.
The Sew Line wastewater series has motors of up to 132 kW, runs without clogging and passes particles of up to 125 mm. SP pumps serve raw or drinking water stations, irrigation, industrial water, sea water, closed cooling circuits, filtration and condensation, and crude oil pumping. For a quotation, send the flow rate, the head and the liquid.
What do we supply from the Layne Bowler range?
| Product | Description |
|---|---|
| Vertical shaft and submersible pumps | Vertical shaft pumps (vertical turbine) serve deep wells. Submersible pumps have a drive shaft and bearings for axial loads and are built to run under water. Geothermal pumps lift geothermal water to the surface. |
| Axial flow pumps | High-flow, low-head pumps used for draining large volumes of water, for example from floods and heavy rain. |
| Multistage and single-stage pumps | Horizontal multistage pumps, DN 32–DN 200, 9 models, with DIN 2533 / PN 16 suction flanges, vertical multistage pumps with a DIN 2535 / PN 40 discharge flange and standardised single-stage pumps DIN 24255 / EN 733. |
| SP double-suction pumps and Sew Line pumps | SP is the series with a split casing, double suction and radial flow. Sew Line is the wastewater series, with motors up to 132 kW, clog-free operation and particles of up to 125 mm. |
Why Layne Bowler?
- Vertical shaft pumps for deep wells — they solve intakes where other pump types can no longer lift the water
- Axial flow pumps for large flow rates at low heads — suited to draining flood water and heavy rainfall
- The Sew Line series passes particles of up to 125 mm — pumping wastewater with solids without frequent clogging
- Single-stage pumps conforming to DIN 24255 / EN 733 — mounting dimensions are easy to check when replacing a standardised pump
- SP split-casing pumps — they can be mounted vertically or horizontally, with the coupling on either side of the motor
Which Layne Bowler codes and series are requested most often?
| Code | Description |
|---|---|
| SP | Double-suction pump, split casing, horizontal shaft, single-stage, radial flow |
| Sew Line | Series of wastewater pumps, motors up to 132 kW, particles up to 125 mm |
| DIN 24255 / EN 733 | Dimensions of standardised single-stage end-suction pumps |
| DIN 2533 / PN 16 | Suction flange on multistage pumps |
| DIN 2535 / PN 40 | Discharge flange on vertical multistage pumps |
| DN 32–DN 200 | Range of nominal diameters of horizontal multistage pumps, 9 models |
Where is Layne Bowler equipment used?
- Water supply — vertical shaft pumps and raw or drinking water stations
- Wastewater — pumps from the Sew Line series
- Geothermal energy — pumps for lifting geothermal water to the surface
- Irrigation and industrial water — SP double-suction pumps
- Crude oil and petroleum products — SP split-casing pumps
How do we supply Layne Bowler in Romania?
We can quote Layne Bowler vertical shaft, axial flow, submersible, multistage, standardised single-stage, SP and Sew Line pumps. For an exact quotation we need the flow rate, the pumping head, the liquid pumped and its temperature, the depth or water level for well pumps, and the motor voltage. If you are replacing an old pump, send a photo of the nameplate and the flange dimensions. Supplied to order, usually in 1–4 weeks; for pumps configured for the application the lead time may be longer. The exact lead time is confirmed in the quotation.
Pump materials and versions are set by the liquid handled and the operating conditions, so we confirm them in the quotation, based on the data you send.
Frequently asked questions about Layne Bowler
What are the SP and Sew Line pumps from Layne Bowler?
SP is a double-suction, split-casing, horizontal-shaft, single-stage pump with radial flow. Sew Line is a series of wastewater pumps with motors up to 132 kW and particles up to 125 mm.
How do I choose between an axial flow pump and a vertical shaft pump?
The choice depends on the head and on the source: axial flow pumps are built for large flow rates at low heads, for example when draining flood water. Vertical shaft pumps serve deep wells or low water levels. Send the flow rate, the head and the depth of the source, and we confirm the suitable type in the quotation.
Do you supply Layne Bowler pumps in Romania, and how quickly?
Pumps are supplied to order, and the lead time is usually 1–4 weeks; an item can ship in 24–72 h when the item is in stock, locally or at the supplier. Well pumps and pumps for large flow rates are configured for the application, and the exact lead time appears in the quotation.
Can I replace an existing single-stage pump?
Yes, if the existing pump is standardised: the dimensions follow DIN 24255 / EN 733, so the fit is checked against the flange and foot dimensions. Send a photo of the nameplate, the flange diameters, the flow rate and the pumping head.
What data do you need for a Sew Line wastewater pump?
Send the flow rate, the pumping head, the nature of the wastewater and the maximum size of the solids, and the motor voltage and power. The Sew Line series passes particles of up to 125 mm and has motors up to 132 kW, and the exact version is set in the quotation.
How do I request a Layne Bowler quotation?
Send the Layne Bowler code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Layne Bowler Pompa Sanayi (manufacturer documentation)