Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Opsens Solutions supplier in Romania

For Opsens Solutions we quote OTG-A, OTG-F and OTG-PM temperature sensors, OTP-M sensors, OPP pressure sensors and signal conditioners, starting from the measured quantity, the range, the cable length and the sheath type.

Headquarters: Québec, Canada

Request a quote

Who is Opsens Solutions and what does it make?

Opsens Solutions is a Canadian manufacturer based in Québec, specialising in fibre-optic sensors and the instruments that read them: temperature, pressure, strain and displacement. An optical sensor is non-electric, so it withstands electromagnetic and radio-frequency fields, microwaves and high-voltage environments, where a thermocouple or an electric transducer would be disturbed. The range is offered to equipment manufacturers and end users.

The OTG temperature sensors use a GaAs crystal at the end of the fibre and SCBG (semiconductor bandgap) conditioners. The OTG-A works between −40 and +250 °C, the OTG-F has a response time of 5 ms and an accuracy of ±0.8 °C, the OTG-P is protected in a stainless steel tube, the OTG-Q has a 1.4 mm PFA tube, sealed at the tip, for immersion, and the OTG-PM (0.15 × 0.15 mm head) and OTG-I (0.22 or 0.36 mm) are used in power electronics modules, up to 350 °C. The OTP-A and OTP-M measure through the birefringence of a crystal, with very low drift. The OPP pressure sensors range from a size of 0.250 mm (OPP-M) to sealed models for immersion (OPP-C) and differential models (OPP-GD).

The range also includes OSP-A and OSP-SW strain sensors (with spot welding), ODP-A and ODP-B displacement sensors, extensometers, WaterSens level sensors, instrumented bolts and CoreSens, RadSens-2, HandySens-G and AccuSens conditioners. The quotation starts from the measured quantity, the range, the cable length, the sheath type and the compatible conditioner.

What do we supply from the Opsens Solutions range?

ProductDescription
OTG-A, OTG-F, OTG-P and OTG-Q temperature sensorsSensors with a GaAs crystal at the tip of the fibre: the OTG-A for general use (−40…+250 °C), the OTG-F with a 5 ms response and an accuracy of ±0.8 °C, the OTG-P in a stainless steel or ceramic tube, the OTG-Q with a sealed PFA tube for immersion. Standard cable of 1.5 m.
OTG-PM, OTG-I and OTP-M sensorsThe OTG-PM and OTG-I (OTG-I220, OTG-I360) have a small tip, for power electronics modules, with a response of a few milliseconds and up to 350 °C. The OTP-M is a high-accuracy sensor, based on birefringence, for 0…85 °C.
OPP pressure sensors and OSP strain sensorsThe OPP-M has a diameter of 0.250 mm, the OPP-B and OPP-GF are used in confined spaces, the OPP-C is sealed for immersion, and the OPP-GD measures bidirectional differential pressure. The OSP-A and OSP-SW measure strain, without periodic calibration.
Signal conditioners and displacement sensorsThe CoreSens, RadSens-2, HandySens-G and AccuSens conditioners read the optical sensors, and the ODP-A and ODP-B measure linear displacement over strokes of 10 and 25 mm, with immunity to electromagnetic interference and lightning.

Why Opsens Solutions?

  • OTG temperature sensors with GaAs — response down to 5 ms (OTG-F) and a range of −40 to +250 °C (OTG-A), immune to EM, RF and microwave fields
  • Versions for power electronics — OTG-PM and OTG-I, with a very small tip (0.15 × 0.15 mm, and 0.22 and 0.36 mm respectively), for direct measurement on semiconductors, up to 350 °C
  • OTP sensors with birefringence — OTP-A (−40…+250 °C) and OTP-M (0…85 °C, high accuracy), with no thermal ageing
  • Pressure, strain and displacement sensors — OPP, OSP and ODP, with the same immunity to electromagnetic interference
  • Signal conditioners — CoreSens, RadSens-2, HandySens-G and AccuSens, plus OEM boards for integration in equipment

Which Opsens Solutions codes and series are requested most often?

CodeDescription
OTG-AGaAs temperature sensor, −40…+250 °C
OTG-FTemperature sensor with 5 ms response
OTG-MSeries of temperature sensors for tip measurement
OTG-PTemperature sensor in a stainless steel tube
OTG-QTemperature sensor with sealed PFA tube, for immersion
OTG-PMSensor for power electronics, up to 350 °C
OTG-I220Sensor for semiconductors, 0.22 mm diameter
OTG-I360Sensor for semiconductors, 0.36 mm diameter
OTP-ATemperature sensor with birefringence, −40…+250 °C
OTP-MHigh-accuracy sensor, 0…85 °C
OPP-MPressure sensor with a diameter of 0.250 mm
OPP-CSealed, submersible pressure sensor
OPP-GDBidirectional differential pressure sensor
OSP-AStrain sensor with long cable
CoreSensSignal conditioner for WLPI sensors
RadSens-2Signal conditioner with high sampling rate

Where is Opsens Solutions equipment used?

  • Energy — measurements in high-voltage environments with electromagnetic interference
  • Power electronics and semiconductors — temperature on power modules and in vacuum chambers
  • Industry and laboratory — processes with radio frequency, microwaves or intense electromagnetic fields
  • Oil and gas — pressure and temperature sensors for difficult environments
  • Geotechnics and structural monitoring — strain, pressure and displacement sensors

How do we supply Opsens Solutions in Romania?

From the Opsens Solutions range we can quote OTG and OTP temperature sensors, OPP pressure sensors, strain and displacement sensors, signal conditioners and OEM boards. Custom configurations are handled as projects. The sensors are supplied to order, usually in 1–4 weeks; for special cable lengths and sheaths, depending on the specification, the lead time can be longer. For a quotation send the measured quantity, the range and accuracy wanted, the cable length, the sheath type, the connector, the number of channels, the conditioner used and the working environment (EM fields, high voltage, vacuum).

On-site installation, training and turnkey measurement systems are outside our offer.

Frequently asked questions about Opsens Solutions

What does Opsens Solutions make?

Opsens Solutions makes fibre-optic sensors for temperature, pressure, strain and displacement, as well as signal conditioners and OEM boards. It is based in Québec, in Canada. The sensors are designed for environments with electromagnetic interference, high voltage and microwaves.

How do I choose between an OTG and an OTP sensor?

OTG sensors use a GaAs crystal and have a fast response, from 5 ms on the OTG-F; OTP sensors use birefringence and are chosen for stability and accuracy, for example the OTP-M over 0…85 °C. Send the range, the response speed, the environment and the conditioner available for checking.

Do you supply Opsens sensors in Romania, and how fast?

Yes. The lead time is 24–72 h when the item is in stock, locally or at the supplier; sensors are usually supplied to order, in 1–4 weeks. Depending on the specification, the lead time can be longer for special cable lengths or sheaths; we confirm it in the quotation.

Can I use a new optical sensor with an existing Opsens conditioner?

Compatibility depends on the family: OTG works with SCBG conditioners, and OTP, OPP and OSP with WLPI conditioners (white-light polarisation interferometry). A match is checked case by case. Send the model of the conditioner and of the old sensor, the number of channels and the cable length, and we check the version before the quotation.

What data should I send for a quotation on a fibre-optic temperature sensor?

The temperature range and accuracy wanted, the response time, the cable length, the sheath type (PVC, PTFE, PFA or metal), the connector, the environment (EM fields, high voltage, vacuum, liquid) and the conditioner used are needed. If you are replacing a sensor, send the old code.

How do I request a Opsens Solutions quotation?

Send the Opsens Solutions code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Opsens Solutions (manufacturer documentation)