Rion supplier in Romania
Sound level meters, vibration meters and vibration analysers
Founded in 1944 · Headquarters: Kokubunji (Tokyo), Japan
Who is Rion and what does it make?
Rion is a Japanese company, listed on the Tokyo stock exchange, based in Kokubunji, in the metropolitan area of the capital. It was founded in 1944, and its name comes from 'rigaku' (science) and 'onkyogaku' (acoustics). The business has two branches: medical and audiological devices, and environmental equipment, that is, sound and vibration measuring instruments and particle counters. For maintenance and EHS, the second branch is the relevant one.
The noise instruments include class 1 and 2 sound level meters: NL-43 (class 2), NL-53 and NL-63 (class 1), NL-28 and NL-38 in compact format, NA-28 with octave and third-octave band analysis, plus the NB-14 dosimeter, which measures an employee's personal exposure. For vibration, the VA-14 is an analyser with FFT for machine diagnosis, the VM-83 a vibration meter with inputs for piezoelectric or servo accelerometers, and the VM-54 measures acceleration on three axes. The AS-60 software manages environmental data, and the NX options add FFT or real-time analysis to the NL series.
Such instruments are found in occupational and environmental noise measurements, in checking rotating machinery and in test laboratories. The class of the sound level meter, the frequency range, the accessories (microphone, accelerometer, calibrator) and the optional software are chosen according to the standard required, and if the instrument is used for official measurements, the metrological verification required must be checked.
What do we supply from the Rion range?
| Product | Description |
|---|---|
| NL-43 / NL-53 / NL-63 sound level meters | Sound level meters with SD card memory, trigger and data marking functions, Leq measurement and percentiles. The NL-43 is class 2, while the NL-53 and NL-63 are class 1; options for audio recording, FFT analysis and octave analysis. |
| NL-28 and NL-38 compact sound level meters | Instruments with an OLED screen, easy to use with one hand, for industrial noise, traffic, construction and vehicle checks. The NL-38 is class 1, runs on two AA batteries and can export data as a CSV file. |
| VA-14 vibration analyser | A portable instrument with an FFT function for machine diagnosis and field measurements, with a LAN terminal for file transfer. With the optional VX-14S software a microphone can be connected, and the instrument also measures sound. |
| VM-83 and VM-54 vibration meters | The VM-83 accepts piezoelectric or servo accelerometers and has four connector types, with measurement of acceleration, velocity and displacement. The VM-54 measures acceleration on the X, Y and Z axes, with AC outputs for recorders. |
Why Rion?
- Sound level meters declared compliant with IEC 61672-1:2013 — NL-43 in class 2, NL-38 and the NL-53/NL-63 series in class 1, for noise measurements with standard requirements
- LAN connectivity on the NL-53 series — remote noise monitoring, including from a browser, without a dedicated application
- FFT and real-time analysis through optional software — NX-43FT and NX-43RT extend the NL series without changing the instrument
- Vibration meters with several sensor types — the VM-83 accepts piezoelectric or servo accelerometers and measures acceleration, velocity and displacement
- NB-14 personal noise dosimeter — assesses the exposure of each employee in a noisy workplace
Which Rion codes and series are requested most often?
| Code | Description |
|---|---|
| NL-43 | Class 2 sound level meter, IEC 61672-1:2013 |
| NL-53 | Class 1 sound level meter, with LAN connectivity |
| NL-63 | Class 1 sound level meter, from the same family as the NL-53 |
| NL-28 | Compact class 2 sound level meter, with OLED screen |
| NL-38 | Compact class 1 sound level meter, powered by two AA batteries |
| NA-28 | Class 1 sound level meter with octave and third-octave analysis |
| NB-14 | Noise dosimeter for the personal exposure of employees |
| VA-14 | Portable vibration analyser with FFT |
| VM-83 | Vibration meter with input for piezoelectric or servo accelerometers |
| VM-54 | Triaxial vibration meter for acceleration on X, Y, Z |
| UV-15 | Amplifier unit for accelerometers, up to 16 channels |
| AS-60 | Software for managing environmental measurement data |
Where is Rion equipment used?
- Industrial maintenance — vibration diagnosis on motors, pumps and rotating machinery
- Occupational safety and health — occupational noise and dosimetry
- Environment — industrial, traffic and building site noise
- Testing and laboratories — vibration measurements in research and development
- Cleanliness control — particle counters for cleanrooms
How do we supply Rion in Romania?
We can quote Rion sound and vibration measuring instruments based on the exact model, the accessories and the optional software needed, such as NX-43RT or VX-14S. Supply is to order, usually in 1–4 weeks, and for configurations with options the lead time may be longer and is confirmed in the quotation. For a correct answer we need to know the purpose of the measurement (occupational noise, environmental noise or vibration on machinery), the accuracy class required, the type of sensor or microphone and whether the instrument must be supplied with a calibration certificate.
The types of metrological verification accepted in Romania for a given instrument are established for that specific instrument.
Frequently asked questions about Rion
What products does Rion make?
Rion, founded in Japan in 1944, makes audiological and medical devices, noise and vibration measuring instruments (sound level meters, vibration analysers, vibration meters, seismometers) and particle counters. The measurement side is the one relevant for maintenance, occupational safety and the environment.
How do I choose between a class 1 and a class 2 sound level meter?
Class 1 has tighter tolerances and is chosen when the standard or the measurement method requires it, for example for environmental noise or for official reports. Class 2 is suitable for routine checks. Send us the applicable standard and the measurement situation, so that we can indicate the model from the NL or NA series.
Can you supply Rion instruments in Romania, and with what lead time?
Yes. The instruments are supplied to order; the interval is usually 1–4 weeks, longer if software options or a calibration certificate are required. The lead time results from the model and the accessories, and the exact lead time appears in the quotation.
Can I add FFT or octave analysis to an existing Rion sound level meter?
For the NL-43/53/63 series there are optional software programs, for example NX-43FT for FFT and NX-43RT for octave and third-octave analysis. Compatibility depends on the model and the firmware version, so send us the instrument series and the year of manufacture.
What details should I give for a quotation on a vibration analyser?
The type of machinery, the frequency range, the type of accelerometer used or wanted, the FFT analysis requirement and whether you need sound measurement with the same instrument. For the VA-14 state whether you want the VX-14S option, so that we include the microphone in the quotation.
How do I request a Rion quotation?
Send the Rion code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Rion Co., Ltd. (manufacturer documentation)