SATEC supplier in Romania
For SATEC we quote the PM180 analyser, the PRO series, PM130 PLUS, PM135, PM172 and EM133 meters, the BFM136 circuit monitor, HACS sensors and the RGM180 display, on the basis of the accuracy class and the number of circuits.
Founded in 1987 · Headquarters: Jerusalem, Israel
Who is SATEC and what does it make?
SATEC is an Israeli manufacturer based in Jerusalem, active since 1987, of power quality analysers, multifunction meters, fault recorders and communication instruments for substations, industrial installations and commercial buildings. The devices measure voltage, current, power, energy, harmonics and network events and send them to SCADA or energy management systems. The range operates at temperatures from −40 to 70 °C, with 12 kV surge protection and humidity resistance of up to 98%.
The PM180 power quality analyser is modular, with boards that can be changed under voltage, and has Class A according to IEC 61000-4-30, edition 3, with 0.2/0.2 S accuracy to IEC 62053-22. The PRO series adds the IEC 61850, DNP3 and IEC 60870-5-101/104 protocols, waveform recording on 16 GB and AC and DC measurement. The PM130 PLUS, PM135, PM172 and EM133 meters cover everything from DIN rail measurements, with MID certification (the European measuring instruments directive) for billing, to class 0.2 S metering in substations. BFM136 monitors up to 12 three-phase circuits or 36 single-phase ones, while BFM-II and BFM-DFR add digital fault recording. HACS current sensors replace external current transformers, with 0.1% accuracy on the closed-core models and 0.5% on the split-core ones. RGM180 is the 5.7 inch touch display, ETC ONE Plus and ETC-II are gateways, PAS is the configuration software, and Expertpower is the cloud energy management platform.
Such devices appear in medium and high voltage substations, in factories that monitor their consumption by circuit, in data centres and in renewable installations. The choice depends on the accuracy class, the number of circuits, the protocols towards SCADA and the mounting method, which is why the quotation starts from the measurement scheme and the existing device.
What do we supply from the SATEC range?
| Product | Description |
|---|---|
| PM180 and the PRO series | Class A power quality analysers, with 0.2/0.2 S accuracy, fault recorder and phasor measurement unit functions, modular extensions and substation protocols; the PRO series adds direct current measurement. |
| PM130 PLUS, PM135, PM172 and EM133 | Three-phase multifunction meters for substations and SCADA: PM172 of class 0.2 S with harmonics and total harmonic distortion (THD), PM130 PLUS with direct current measurement through a shunt, PM135 with an LCD display and load bar, EM133 on a DIN rail, with MID certification. |
| BFM136, BFM-II and BFM-DFR | Branch circuit monitors: BFM136 for 12 three-phase or 36 single-phase circuits, BFM-II and BFM-DFR with digital fault recording at 40 times the rated current, intended for substation upgrades, with HACS sensors. |
| HACS, RGM180, ETC and Expertpower | HACS current sensors with a safety switch, the 5.7 inch RGM180 display for up to 32 devices, the ETC ONE Plus and ETC-II gateways and the Expertpower platform, on Microsoft Azure, for metering, billing and power quality analysis. |
Why SATEC?
- Modular Class A analyser — PM180 complies with IEC 61000-4-30 edition 3 and accepts expansion boards that can be changed under voltage
- Substation protocols — the PRO series speaks IEC 61850, DNP3 and IEC 60870-5-101/104 and records waveforms on 16 GB
- HACS current sensors — a single integrated transformer instead of external transformers, with 0.1% accuracy on closed core and 0.5% on split core
- Monitoring of several circuits — BFM136 tracks up to 12 three-phase or 36 single-phase circuits with a single device
- DIN rail meter with MID certification — EM133 can meter three separate single-phase loads and has a tamper-proof housing
Which SATEC codes and series are requested most often?
| Code | Description |
|---|---|
| PM180 | Class A power quality analyser, modular |
| PRO Series | Analyser and meter with IEC 61850, AC and DC |
| PM172 | Three-phase class 0.2 S meter with harmonics |
| PM135 | Multifunction meter with LCD display |
| PM130 PLUS | Multifunction meter with DC measurement through a shunt |
| EM133 | DIN rail meter with MID certification |
| BFM136 | Monitor for 12 three-phase or 36 single-phase circuits |
| BFM-II | Branch circuit monitor, modular |
| BFM-DFR | Monitor with digital fault recording |
| HACS | High-accuracy current sensor, closed or split core |
| RGM180 | 5.7 inch touch display for SATEC devices |
| ETC ONE Plus | Serial-to-network gateway, up to 32 devices |
| ETC-II | Data server and gateway for Modbus instruments |
| EDL180 | Portable version of the PM180 analyser, Class A |
| PAS | Configuration and analysis software, supplied with the devices |
| Expertpower | Cloud energy management platform |
Where is SATEC equipment used?
- Substations — class 0.2 S metering, fault recording and power quality monitoring
- Industry — monitoring of consumption by circuit and energy management
- Commercial buildings and data centres — metering by consumer and billing
- Renewable sources — measurement in alternating and direct current
- Utilities — meters for statistics and SCADA control, used as small remote terminal units (RTU)
How do we supply SATEC in Romania?
We can quote SATEC power quality analysers, multifunction meters, circuit monitors, HACS sensors and gateways, bringing them in to order. The lead time is usually 1–4 weeks to order, and depending on the specification it can be longer for configurations with expansion boards. For a quotation, send us the model of the old device, the accuracy class, the number of circuits, the rated voltage and currents, the communication protocols needed, the mounting type (panel, DIN rail) and whether you need fault recording or power quality functions. The exact lead time is confirmed in the quotation.
The meter model is chosen together with the accuracy class, the number of circuits and the protocols required by SCADA, not before.
Frequently asked questions about SATEC
What does SATEC make?
SATEC, from Jerusalem and active since 1987, makes power quality analysers, multifunction meters, circuit monitors, fault recorders, HACS current sensors, gateways and the Expertpower platform. The devices are designed for substations, industry and commercial buildings.
How do I choose between PM180, PM172 and EM133?
PM180 is a modular Class A power quality analyser, for substations. PM172 is a three-phase class 0.2 S meter, with basic harmonics. EM133 is mounted on a DIN rail and has MID certification for commercial metering. Send us the mounting location and the accuracy class required.
Do you supply SATEC devices in Romania and how long does it take?
Yes, to order, usually in 1–4 weeks; depending on the specification, the lead time can be longer, for example for PM180 with expansion boards. The exact lead time is confirmed in the quotation, once we receive the configuration.
What do you check if I replace an older SATEC meter?
We check the model and series on the nameplate, the rated voltages and currents, the protocols used towards SCADA, the number of inputs and outputs and the mounting type. Equivalence is confirmed once these data are compared; HACS sensors also depend on the connected device.
What do I send for a quotation for a BFM136 circuit monitor?
Send the number of three-phase and single-phase circuits to be monitored, the rated currents, the type of current sensors (HACS, closed or split core), the communication protocol and whether the project is new or an upgrade. BFM136 covers 12 three-phase or 36 single-phase circuits.
How do I request a SATEC quotation?
Send the SATEC code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: SATEC (manufacturer documentation)