SAES Getters supplier in Romania
CapaciTorr NEG pumps and NEXTorr hybrids
Founded in 1940 · Headquarters: Lainate (Milano), Italy
Who is SAES Getters and what does it make?
SAES Getters was founded in 1940 in Florence and is today based in Lainate, near Milano. The company works with advanced materials (shape memory alloys, polymers, barrier coatings), but for a vacuum engineer the interest lies in the high-vacuum division, born from "getter" alloys, that is, materials that selectively bind active gases and maintain the vacuum. The company has collaborated with CERN since 1980, and the technique of coating chambers with a NEG layer, developed for the LHC accelerator, is now sold under the IntegraTorr brand.
The range of non-evaporable getter (NEG) pumps has three main families. CapaciTorr D and Z are flanged NEG pumps with sintered discs: the D series uses the St 172 alloy, in use in UHV and XHV applications since the 1990s, and the Z series the ZAO® alloy, with a higher hydrogen pumping speed and activation in about an hour. CapaciTorr HV, with an easily replaceable NEG cartridge, is used in high vacuum (models HV 200 on CF35 and CF63, HV 1600 and HV 2100). NEXTorr combines in a single body a sputter ion pump and a NEG element, in the D and Z series for UHV and in the HV 1200 version for high vacuum.
For Romania, requests come from physics laboratories, research institutes, analytical equipment manufacturers and deposition plants that need a replacement pump. The flangeless modules (UHV Wafer Module) are used in chambers with limited conductance. The exact code, the flange, the activation regime and the associated power supply must be confirmed before ordering.
What do we supply from the SAES Getters range?
| Product | Description |
|---|---|
| CapaciTorr D and Z (UHV/XHV) | Flanged NEG pumps with sintered discs, intended for pressures of 10⁻⁹ Torr and lower. The Z series has a higher speed for hydrogen, improved mechanical strength and reduced outgassing at activation; more than 100 reactivations are possible. |
| CapaciTorr HV | NEG pumps for high vacuum, with ZAO® alloy, early activation at pressures of the order of 10⁻² Torr and constant operation at about 200 °C. Models include HV 200 on CF35 and CF63, HV 1600 and HV 2100. |
| NEXTorr D, Z and HV | Hybrid NEG plus sputter ion pumps. On the CF35 and CF63 models the ion pump has 6 l/s for argon and 15 l/s for methane; there are also versions on CF100 and the D500 variants with StarCell, and HV 1200 covers high vacuum. |
| UHV Wafer Module and IntegraTorr | The UHV Wafer Module is a flangeless NEG pump, for mounting inside the chamber, with ZAO® alloy discs. IntegraTorr is a NEG coating deposited on chamber walls, used in accelerators and synchrotron light sources. |
Why SAES Getters?
- Two NEG alloys for UHV — St 172 in the D series and ZAO® in the Z series, with better hydrogen pumping and activation at lower temperatures
- Operation without power after activation — CapaciTorr NEG pumps work at room temperature, without oil and without vibration
- NEXTorr hybrid pumps — a NEG element and a sputter ion pump in a single body, suited to small spaces
- Replaceable NEG cartridge — on CapaciTorr HV, with more than 20 effective sorption cycles at about 200 °C
- IntegraTorr NEG coating — distributed pumping on the surface of accelerator chambers, a technique that came out of work at CERN
Which SAES Getters codes and series are requested most often?
| Code | Description |
|---|---|
| CapaciTorr D 3500 | High-capacity NEG pump, D series |
| CapaciTorr Z 3500 | High-capacity NEG pump, Z series (ZAO alloy) |
| CapaciTorr HV 200 (CF35) | NEG pump for high vacuum on CF35 flange |
| CapaciTorr HV 200 (CF63) | NEG pump for high vacuum on CF63 flange |
| CapaciTorr HV 1600 | NEG pump for high vacuum, high pumping speed |
| CapaciTorr HV 2100 | NEG pump for high vacuum, maximum capacity in the HV series |
| NEXTorr D 500 | Hybrid NEG + ion pump, D series |
| NEXTorr Z 100 | Hybrid NEG + ion pump, Z series |
| NEXTorr HV 1200 | Hybrid NEG + ion pump for high vacuum |
| UHV Wafer Module | Flangeless NEG pump for mounting in the chamber |
| IntegraTorr | NEG coating sputtered onto vacuum chambers |
Where is SAES Getters equipment used?
- Particle accelerators and synchrotron sources — distributed pumping and NEG coatings
- Scientific research — UHV and XHV chambers for physics and materials
- Analytical instruments — compact pumps with a NEG element
- Semiconductor manufacturing — clean vacuum applications
- Aerospace — components with getter alloys and vacuum systems
How do we supply SAES Getters in Romania?
We can take requests for SAES NEG and hybrid pumps (CapaciTorr, NEXTorr), flangeless modules and associated components. Supply is to order; for standard items the lead time is usually 1–4 weeks, and for special configurations or custom coatings it may be longer, confirmed in the quotation. For a correct quotation, send us the pump code, the flange (for example CF35, CF63 or CF100), the target pressure, the dominant gases, the activation temperature available and the type of power supply used to activate the NEG element.
Power supplies or cables compatible with an older pump model and the effective pumping speeds of a specific installation are established from the model and the installation data.
Frequently asked questions about SAES Getters
What does SAES Getters make in the vacuum field?
SAES Getters, founded in 1940 and based in Lainate, makes non-evaporable getter pumps (CapaciTorr), hybrid NEG plus ion pumps (NEXTorr), flangeless modules (UHV Wafer Module) and NEG coatings (IntegraTorr), used in accelerators, synchrotrons and research systems.
How do I choose between the D series and the Z series in CapaciTorr?
The D series uses the St 172 alloy, established in UHV applications, while the Z series uses ZAO®, with a higher speed for hydrogen and activation in about an hour, including at lower temperatures. Send us the dominant gas, the target pressure and the activation temperature available.
Do you supply SAES pumps in Romania, and in what time?
Yes, to order. Standard pumps usually take 1–4 weeks to order, and special configurations may need longer. The exact lead time appears in the quotation.
What is the difference between CapaciTorr and NEXTorr?
CapaciTorr is a pure NEG pump, which binds active gases but does not pump noble gases and methane. NEXTorr adds a sputter ion pump in the same body, so it also covers argon and methane, in a compact format. Send us the composition of the gases in the chamber.
What details should I give for a NEG pump quotation?
The pump code or, for a new one, the flange (CF35, CF63, CF100), the target pressure, the gases present, the chamber volume, the possibility of bake-out and the power supply available for activation. For replacing an element, add the series of the existing pump.
How do I request a SAES Getters quotation?
Send the SAES Getters code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: SAES Getters S.p.A. (manufacturer documentation)