Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Canon Anelva supplier in Romania

Cryogenic pumps, vacuum gauges and leak detectors

Founded in 1967 · Headquarters: Kawasaki, Japan

Request a quote

Who is Canon Anelva and what does it make?

Canon Anelva (CANON ANELVA CORPORATION) is a Japanese manufacturer based in Kawasaki, in Kanagawa Prefecture, founded in 1967. Its activity is based on ultra-high vacuum technology: the company builds equipment for thin-film deposition, etching and bonding for semiconductors and electronic components, as well as vacuum components sold separately. For a maintenance or purchasing department, the component line is of particular interest: cryogenic pumps and other vacuum pumps, vacuum gauges, vacuum valves and switches, quadrupole mass spectrometers, helium leak detectors and X-ray sources.

The codes are meaningful in themselves. Cryogenic pumps appear in the P-0xx/P-1xx/P-2xx family, with C or CL suffixes, helium leak detectors in the M-212LD and M-222LD series (with D variants), quadrupole mass spectrometers in M-101QA and M-201QA, and valves in the V series (for example V-025RV-CN or V-040LV-STD). For some older items there are discontinuation notices and successor models, which matters for replacement.

Such equipment appears in a vacuum deposition installation, a research laboratory or an analysis system. To replace a cryogenic pump, a vacuum gauge or a valve, you need to know the full code, the flange, the supply voltage and whether the model is still in production or has received a successor indicated by the factory.

What do we supply from the Canon Anelva range?

ProductDescription
Cryogenic pumps (P-0xx / P-1xx / P-2xx)Family of cryogenic pumps for vacuum chambers, with numerous models suffixed C or CL. For cryogenic pumps, the manufacturer has maintenance and component replacement programmes.
Helium leak detectorsThe M-212LD and M-222LD series, with D variants, for locating leaks in vacuum systems and components.
Quadrupole mass spectrometersModels M-101QA-TDF, M-101QA-TDM and M-201QA-TDM, instruments for analysing gases in vacuum chambers, used to check the composition of the residual atmosphere.
Vacuum gauges, valves and switchesVacuum gauges such as M-431HG, TG-550B and LG-11S, plus V-series vacuum valves (V-025RV-CN, V-040LV-STD, V-065LV-STD, V-100LV-STD) for isolating and regulating vacuum circuits.

Why Canon Anelva?

  • Specialisation in ultra-high vacuum — the company builds its equipment and components on vacuum technology, from pumps to deposition systems
  • Varied range of pumps — from low vacuum to ultra-high vacuum, including cryogenic pumps
  • Leak detectors and spectrometers — the M-212LD, M-222LD and M-101QA/M-201QA series for leak testing and gas analysis
  • Successor models — for some discontinued models, for example the P-421CA compressor unit, there are successors indicated by the factory
  • X-ray source for non-destructive testing — microfocus sources for industrial inspection

Which Canon Anelva codes and series are requested most often?

CodeDescription
P-080CCryogenic pump from the P-0xx family
P-086CCryogenic pump from the P-0xx family
P-106CCryogenic pump from the P-1xx family
P-126CCryogenic pump from the P-1xx family
P-201CCryogenic pump from the P-2xx family
M-212LDHelium leak detector
M-222LDHelium leak detector
M-101QA-TDFQuadrupole mass spectrometer
M-201QA-TDMQuadrupole mass spectrometer
M-431HGVacuum gauge
V-025RV-CNV-series vacuum valve
V-040LV-STDV-series vacuum valve

Where is Canon Anelva equipment used?

  • Semiconductors — deposition, etching and bonding in vacuum
  • Electronic components — thin films for electronic devices
  • Research — ultra-high vacuum systems and gas analysis
  • Vacuum equipment manufacturers — replacement pumps, valves and vacuum gauges
  • Non-destructive testing — microfocus X-ray sources for inspection

How do we supply Canon Anelva in Romania?

We can take requests for Canon Anelva components (cryogenic pumps, vacuum gauges, valves, mass spectrometers, leak detectors) and for spare parts for existing installations. Supply is to order, usually in 1–4 weeks for standard items, with a longer lead time for rare or discontinued models; the exact lead time is confirmed in the quotation. For an accurate quotation send us the full code from the nameplate (for example P-086C or M-222LD), the series and year of manufacture, the supply voltage, the flange and, for an installation, the type of process in which the equipment operates.

The current production of an older model and the mechanical and electrical fit of the successor indicated by the factory in your installation are checked case by case.

Frequently asked questions about Canon Anelva

What products does Canon Anelva make?

Canon Anelva, founded in 1967 in Kawasaki, makes equipment for thin-film deposition, etching and bonding in vacuum, as well as vacuum components: cryogenic pumps, vacuum gauges, valves, quadrupole mass spectrometers, helium leak detectors and X-ray sources.

How do I identify a Canon Anelva cryogenic pump?

Cryogenic pumps have codes of the form P-086C or P-126CL, with C or CL suffixes for variants. To identify it correctly, send us the code from the nameplate, the mounting flange, the voltage and the type of compressor or cooling unit used in the installation.

Can Canon Anelva components be supplied in Romania, and how quickly?

Yes, to order. Standard items: usually 1–4 weeks; rare or discontinued models may take longer, sometimes with a successor indicated by the factory. We give the exact lead time in the quotation, after the code has been identified.

What if my model has been discontinued?

For some discontinued models there are successors, for example for the P-421CA compressor unit. We check whether there is a successor indicated by the factory on the basis of your code; mechanical and electrical compatibility is confirmed before the quotation.

What data do I need to send for a quotation for a vacuum valve or a vacuum gauge?

The full code on the part (for example V-040LV-STD), the size and type of the flange, the control voltage for the valve, the pressure range for a vacuum gauge and, if available, a photo of the nameplate.

How do I request a Canon Anelva quotation?

Send the Canon Anelva code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Canon Anelva Corporation (manufacturer documentation)