SKC Inc. supplier in Romania
For SKC we quote AirChek Essential, Connect and TOUCH pumps, Pocket Pump TOUCH, Anasorb sorbent tubes, PPI impactors, chek-mate flow meters and filters, based on the agent measured, the flow rate and the analysis method.
Headquarters: Eighty Four, USA
Who is SKC Inc. and what does it make?
SKC Inc. makes, in Eighty Four (Pennsylvania), equipment for industrial hygiene and workplace exposure monitoring: air sampling pumps, collection media (sorbent tubes, filters, impactors), verification flow meters, samplers for aerosols, surfaces and skin contact, direct-reading instruments, noise dosimeters and acoustic calibrators.
The AirChek personal pumps, in the Essential, Essential+, Connect and TOUCH versions, and the Pocket Pump TOUCH are worn by the worker and draw a constant flow through a collection medium. For gases and vapours, sorbent tubes are used, for example Anasorb CSC from the 226-01 and 226-09 series, plus the thermal desorption tubes from the 226-300 series. For particles there is the Personal Parallel Impactor, at 2, 4 or 8 L/min, and the single-use personal impactors, preloaded and pre-weighed, for 3 L/min. The chek-mate flow meters cover ranges of 20–500 ml/min, 0.5–5 L/min and 5–30 L/min, and the LeadSense kit quickly checks surfaces for lead contamination.
These are tools for occupational health and safety specialists and accredited laboratories, who work to standardised sampling and analysis methods. The quotation starts from the agent measured (gas, vapours, particles), the sampling method, the flow rate required and the pump type, and for collection media from the exact item code, in relation to the analysis method of your laboratory.
What do we supply from the SKC Inc. range?
| Product | Description |
|---|---|
| AirChek Essential, Essential+, Connect and TOUCH; Pocket Pump TOUCH | Personal air sampling pumps for industrial hygiene, worn by the worker. They draw a constant flow through a sorbent tube or a filter, and the Connect and TOUCH versions add connectivity and a touch screen for setup and data download. |
| Anasorb sorbent tubes and the 226-300 series | Tubes for organic vapours and gases, with coconut shell charcoal (Anasorb CSC) in two sections, for example 6 × 70 mm (226-01) and 8 × 110 mm (226-09). The 226-300 series comprises the thermal desorption tubes. |
| Personal Parallel Impactor (PPI) and single-use personal impactors | The PPI collects the respirable fraction at 2, 4 or 8 L/min on a pre-weighed PVC filter. The single-use impactors work at 3 L/min for PM10 and PM2.5, are supplied preloaded and are discarded after the sample is prepared for analysis. |
| chek-mate flow meters, filters and LeadSense kit | The chek-mate flow meters verify pump flow in three ranges, with a NIST certificate. The PTFE, MCE, PVC and glass fibre filters come in diameters of 13, 25 and 37 mm. LeadSense is the swab kit for quick detection of lead on surfaces. |
Why SKC Inc.?
- Personal pumps for constant flow — AirChek Essential, Essential+, Connect and TOUCH, plus Pocket Pump TOUCH, for workers on the move
- Two-section sorbent tubes — Anasorb CSC in the 6 × 70 mm (226-01) and 8 × 110 mm (226-09) versions, with a backup section for detecting breakthrough
- Parallel particle impactors — PPI at 2, 4 or 8 L/min, and the larger air volume lowers the detection limit
- Single-use personal impactors — preloaded, pre-weighed and supplied with an adapter for flow verification, without a calibration jar
- Field flow verification — the chek-mate flow meters cover 20 ml/min to 30 L/min, with a NIST certificate (the American metrology institute)
Which SKC Inc. codes and series are requested most often?
| Code | Description |
|---|---|
| 220-1000TC | Pocket Pump TOUCH, personal sampling pump |
| 220-3000 | AirChek Essential, personal pump |
| 220-3100 | AirChek Essential+, personal pump |
| 220-4000 | AirChek Connect, personal pump with connectivity |
| 220-5000TC | AirChek TOUCH, personal pump with touch screen |
| 226-01 | Anasorb CSC tube, 6 × 70 mm, 100/50 mg |
| 226-09 | Anasorb CSC tube, 8 × 110 mm, 400/200 mg |
| 226-300 | Series of thermal desorption tubes |
| 225-3851-PW | Parallel particle impactor, 2 L/min, pre-weighed PVC filter |
| 225-3871-PW | Parallel particle impactor, 4 L/min, pre-weighed PVC filter |
| 375-00205N | chek-mate flow meter, 20–500 ml/min |
| 375-0550N | chek-mate flow meter, 0.5–5 L/min |
| 375-50300N | chek-mate flow meter, 5–30 L/min |
Where is SKC Inc. equipment used?
- Industrial hygiene — monitoring worker exposure to gases, vapours and particles
- Accredited analysis laboratories — collection media and pre-weighed samples
- Mining — sampling of respirable particles for exposure assessment
- Chemical and metallurgical industry — organic vapours, metals and dust
- Occupational safety and health — noise, surface contamination and lead exposure
How do we supply SKC Inc. in Romania?
From the SKC range we can quote the AirChek and Pocket Pump series sampling pumps, sorbent tubes, filters, PPI impactors, chek-mate flow meters and sampling kits, supplied to order. Lead time: usually 1–4 weeks, to order, and depending on the specification it can be longer. To identify items, send the code (for example 220-3000 or 226-09), the substance or agent to be measured, the flow rate required, the analysis method followed and the quantity. For collection media, the exact type is usually indicated by the method required by your laboratory.
The analysis method and the type of collection medium are set by the laboratory and the applicable standard.
Frequently asked questions about SKC Inc.
What does SKC Inc. make?
SKC makes sampling and measuring equipment for industrial hygiene: AirChek and Pocket Pump personal pumps, sorbent tubes, filters and impactors, flow meters, samplers for aerosols and surfaces, noise dosimeters and acoustic calibrators. The headquarters is in Eighty Four, Pennsylvania.
How do I choose the pump and the collection medium for a substance?
The collection medium and the flow rate are dictated by the analysis method: Anasorb tubes for organic vapours, filters for particles, impactors for the respirable fraction. The pump must keep the flow constant throughout the cycle. Tell us the substance, the method and the sampling duration, so that we check the combination.
Do you bring SKC products to Romania, and within what lead time?
The products are supplied to order, usually in 1–4 weeks; an item can ship in 24–72 h when the item is in stock, locally or at the supplier. High-volume orders and special media can exceed this period, and the exact value is set in the quotation.
Does a newer SKC tube or pump follow the same method as the old item?
The item code, the flow rate, the tube dimensions and the analysis method are checked. Equivalence is confirmed only on the basis of this data; send the code or a photo of the packaging, and we find out from the supplier whether the current version follows the same method.
What data should I send for a quotation on an AirChek pump?
Send the model or code (for example 220-3000), the working flow rate required, the sampling duration, the collection medium used, whether you need connectivity or a touch screen and the accessories wanted: holder, charger, calibration adapter. With this data we determine the suitable version.
How do I request a SKC Inc. quotation?
Send the SKC Inc. code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: SKC Inc. (manufacturer documentation)