Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

ACO supplier in Romania

For ACO we quote grease separators, light-liquid separators, floor drains and channels and Muli-Max and Powerlift pumping stations; we need the flow rate, the medium and the installation site.

Founded in 1946 · Headquarters: Büdelsdorf, Germany

Request a quote

Who is ACO and what does it make?

ACO is a German group, founded in 1946 on the grounds of the Carlshütte foundry near Rendsburg, with its headquarters in Büdelsdorf. The company started with concrete building elements, and in the 1960s moved on to the first drainage channels; in the 1970s it launched the ACO DRAIN® polymer concrete system, which took it into foreign markets. Today the group works with polymer concrete, high-performance concretes, plastic, cast iron and stainless steel, and its product lines cover drainage of buildings and surfaces, separation of grease and light liquids, and removal of wastewater.

The drainage offer for buildings is organised in four functions: collection, cleaning, retention and discharge. Collection includes floor drains in cast iron, stainless steel, plastic or biopolymer, box and slot channels, and roof, balcony and multi-storey car park drainage. For cleaning there are grease separators to EN 1825 and DIN 4040-100, in free-standing, below-ground or under-sink versions, such as ACO Grease Capture and Lipumobil-P, light-liquid separators for car parks, car washes and workshops, starch separators and sludge removal units. For discharge there are pumping and lifting stations for wastewater, among them Muli-Max and Powerlift P, with polyethylene tanks.

For Romania, the relevant sites are industrial kitchens and hotels, the food industry, car parks, petrol stations and halls with washed floors. Sizing depends on the flow rate, the type of wastewater and the standard that applies.

What do we supply from the ACO range?

ProductDescription
Grease separatorsSeparation chambers to EN 1825 and DIN 4040-100, for free-standing, below-ground or kitchen installation, in versions with total or partial discharge; they include ACO Grease Capture, ACO Lipumobil-P and solutions with an integrated lifting station.
Floor drains and channelsDrains in cast iron, stainless steel, plastic and biopolymer and box or slot channels, with extensions and cleaning seals, selected according to the installation site, the load class and the hygiene required.
Light-liquid separatorsWastewater pretreatment installations for water that may contain petrol, benzene, lubricants or oils, using the difference in density; they are installed in car parks, petrol stations, car washes and workshops; sizing depends on the flow rate.
Pumping and lifting stationsPrefabricated Muli-Max and Powerlift P stations, plus solutions for existing manholes, for situations where gravity discharge is not possible, including for wastewater containing faecal matter, with polyethylene tanks.

Why ACO?

  • Grease separators to EN 1825 and DIN 4040-100 — for restaurants, canteens, hotels and food businesses
  • Floor drains in cast iron, stainless steel, plastic or biopolymer — the choice depends on the installation site, for example an industrial kitchen
  • Box and slot channels — linear drainage for halls, car parks and platforms
  • Light-liquid separators — for petrol, oils and lubricants, in multi-storey car parks, petrol stations and workshops
  • Pumping and lifting stations — polyethylene tanks, including downstream of large separators

Which ACO codes and series are requested most often?

CodeDescription
ACO DRAIN®Polymer concrete channel system
ACO Grease CaptureGrease separator for kitchen installation
Lipumobil-PMobile grease separator
Grease separator, free-standingFree-standing grease separator, EN 1825
Grease separator, below groundBelow-ground grease separator, EN 1825
Light-liquid separatorLight-liquid separator with full treatment
Starch separatorStarch separator
Sludge removal unitSludge removal unit
Muli-MaxPrefabricated pumping station
Powerlift PPrefabricated pumping station
Box channelsFloor box channel
Slot channelsFloor slot channel
Backflow systemsBackflow prevention systems

Where is ACO equipment used?

  • Industrial kitchens, hotels and canteens — grease separators
  • Food industry — hygienic drainage and grease separation
  • Car parks, petrol stations and car washes — light-liquid separators
  • Industrial halls — floor channels and drains
  • Wastewater installations — pumping and lifting stations

How do we supply ACO in Romania?

From the ACO range we can take requests for floor drains and channels, grease and light-liquid separators, pumping stations and drainage components. Drainage products and separators: standard parts can ship in 24–72 h when the item is in stock, locally or at the supplier, the rest to order, usually 1–4 weeks; installations sized to a project may take longer. For an accurate quotation, send the design flow rate, the type of wastewater, the installation site (in the ground, free-standing or in a kitchen), the load class, the standard that applies and the length of the channels. The exact lead time is given in the quotation.

The separator or pumping station is sized from the design flow rate and the standard that applies to your installation.

Frequently asked questions about ACO

What does ACO make?

ACO makes drainage and wastewater treatment systems: floor channels and drains, grease, light-liquid and starch separators, backflow prevention systems, pumping and lifting stations. The group was founded in 1946 and is based in Büdelsdorf, in Germany.

When does a grease separator have to be installed?

Facilities that produce greasy wastewater, from restaurants and canteens to slaughterhouses and edible oil refineries, must retain organic fats and oils before the sewer network, in line with EN 1825 and DIN 4040-100. Send us the flow rate and the type of facility, and we identify the matching separator from the manufacturer's documentation.

Do you supply ACO products in Romania?

Yes, to order. Standard channels and drains can ship in 24–72 h when the item is in stock, locally or at the supplier; separators and pumping stations are ordered, usually in 1–4 weeks, and large projects may need a longer lead time.

Can I replace an existing drain or channel?

This can be checked starting from the type of material, the load class, the nominal width and the length. Compatibility with the old elements is confirmed from these data and a photo of the installation; the fixing and sealing must match the existing structure.

What data do I need to send for a quotation?

The design flow rate or the number of meals per day for a kitchen, the type of wastewater (greasy, with oils, with starch), the installation site, the depth of the inlet pipe, the load class, the local standard and the channel lengths. A drawing or sketch of the room speeds up the reply.

How do I request a ACO quotation?

Send the ACO code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: ACO Gruppe, ACO Building Drainage (manufacturer documentation)