Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Dynament supplier in Romania

For Dynament we quote Platinum sensors for methane, CO₂ and N₂O, dual-gas HC and CO₂ sensors, Axiom sensors for refrigerants and FGD10A detectors; we need the gas, the range, the certification and the sensor format.

Founded in 2001 · Headquarters: Mansfield, Nottinghamshire, United Kingdom

Request a quote

Who is Dynament and what does it make?

Dynament is a British manufacturer of non-dispersive infrared (NDIR) gas sensors, founded in 2001 and based in Mansfield. The sensors are intended mainly for makers of gas detection instruments, but they also appear as spare parts in existing detectors. The range covers sensors for hydrocarbons (methane and propane), for carbon dioxide, for nitrous oxide and for refrigerants, plus fixed gas detectors, enclosures and a configuration unit. The Platinum series combines the optics, the electronics and the firmware in a single module and can directly replace catalytic pellistor-type sensors, while the Axiom series is dedicated to flammable refrigerants.

Platinum hydrocarbon sensors measure methane from 0 to 100 % by volume, with a resolution of 0.01 % in the 0–5 % range, and propane from 0 to 2 %. The CO₂ ones cover from 500 ppm to 100 % by volume, and the N₂O ones 0–1000 ppm or 0–1 %. The dual-gas versions (HC and CO₂) exist in a standard 80 mA version and a low-power 15 mA version, with variants for explosive atmospheres, according to the manufacturer's documentation, and the functional safety version is available across the whole range of dual-gas sensors. The refrigerant sensors cover R32, R454B, R454C, R290 and R744, in the lower flammability limit range, with a resolution of 0.05 % (500 ppm); Axiom has approvals for refrigerants, according to the manufacturer's documentation, and has an IP68 USB-C connector. The fixed detectors FGD4, FGD5/6, FGD10A, FGD10B and FGD14 can be safe-area, flameproof or intrinsically safe.

The choice starts from the gas measured, the range, the certification required by the area, the permitted power consumption and the way the sensor is mounted in the instrument. For a replacement, the format of the existing sensor matters.

What do we supply from the Dynament range?

ProductDescription
Platinum sensors for hydrocarbons and CO₂NDIR for methane (0–100 %), propane (0–2 %) and carbon dioxide (500 ppm–100 %), with linearised and compensated output, a standard working temperature of -20 to +50 °C and optionally -40 to +75 °C, in four power modes.
Dual-gas HC and CO₂ sensorsA single sensor measures methane, propane and CO₂, with a resolution of 0.01 % in the 0–5 % range, in 80 mA or 15 mA versions, with variants for explosive atmospheres and with functional safety.
Sensors for refrigerants and nitrous oxidePlatinum and Axiom for R32, R454B, R454C, R290 and R744, with a resolution of 0.05 % in the LFL range, plus N₂O sensors of 0–1000 ppm or 0–1 %, with variants for explosive atmospheres and with approvals according to the manufacturer's documentation, as well as without approvals.
FGD fixed detectorsFGD4 and FGD14 for safe areas; FGD5/6, FGD10A and FGD10B flameproof, in variants for explosive atmospheres; the intrinsically safe version. FGD10A has three relays, a 4–20 mA output, a magnetic stylus menu and a cast aluminium or 316 stainless steel enclosure (suffix -SS).

Why Dynament?

  • Platinum with integrated optics and electronics — linearised, temperature-compensated output, without additional conditioning circuits
  • Four power consumption levels — 420, 240, 45 and 24 mW, for mains-powered or battery-powered instruments
  • Dual gas HC and CO₂ — methane, propane and carbon dioxide from a single sensor, with a low-power 15 mA variant
  • Variants for explosive atmospheres, according to the manufacturer's documentation — with functional safety available on all dual-gas sensors
  • Axiom for flammable refrigerants — 500 ppm resolution in the LFL range (lower flammability limit), UL60335-2-40 Annex LL certification and an IP68 USB-C connector

Which Dynament codes and series are requested most often?

CodeDescription
Platinum HCNDIR sensor for methane and propane
Platinum CO₂NDIR sensor for carbon dioxide, 500 ppm–100 %
Platinum N₂ONDIR sensor for nitrous oxide, 0–1000 ppm or 0–1 %
Platinum HC/CO₂Dual-gas sensor, 80 mA or 15 mA
Platinum refrigerantsSensors for R32, R454B, R454C, R290 and R744
AxiomSensor for flammable refrigerants, UL60335-2-40
FGD4Fixed detector for safe areas
FGD5/6Flameproof fixed detector
FGD10AEx d IIC fixed detector, three relays, 4–20 mA
FGD10BFlameproof fixed detector
FGD14Fixed detector for safe areas
NGSH4Enclosure for sensors, uncertified
PremierConfiguration and calibration unit with USB
FGD10A-SSFGD10A with a 316 stainless steel enclosure

Where is Dynament equipment used?

  • Oil and gas — NDIR hydrocarbon sensors in fixed and portable detectors
  • Chemical industry — detection of combustible gases and carbon dioxide
  • Mines — Mining M1 variants for methane
  • Refrigeration and HVAC installations — sensors for flammable refrigerants
  • Biogas and carbon capture — measurement of methane and CO₂

How do we supply Dynament in Romania?

We can quote Dynament NDIR sensors from the Platinum and Axiom series, FGD fixed detectors, enclosures and the configuration unit. We supply them to order; the lead time is usually 1–4 weeks and, for certified versions, it can be longer. For a correct quotation, send the code on the sensor, the gas and the measuring range, the required certification (Ex d IIC, Mining M1, SIL1), the permitted power consumption and the model of the instrument it is mounted in. The exact lead time is confirmed in the quotation.

The availability of a certification or a measuring range is checked against the exact sensor code, and the format must match that of the instrument.

Frequently asked questions about Dynament

What does Dynament make?

Dynament, from Mansfield, makes NDIR infrared gas sensors for methane, propane, carbon dioxide, nitrous oxide and refrigerants, in the Platinum and Axiom series, plus FGD fixed detectors, enclosures and a configuration unit. The sensors are usually mounted in detection instruments.

How do I choose between a single-gas and a dual-gas sensor?

The HC/CO₂ sensor measures methane (0–100 %), propane (0–2 %) and CO₂ (0–100 %) from a single platform, with Ex d IIC and Mining M1 certifications. The single-gas one is enough when only one parameter is monitored. Tell us the gases, the range and the certification required by the work area.

Do you supply Dynament sensors in Romania, and how fast?

Yes, we supply the sensors to order, usually in 1–4 weeks. Codes can ship in 24–72 h when the item is in stock, locally or at the supplier. Certified versions or special ranges can exceed this lead time, and the exact date appears in the quotation.

Can I replace a catalytic sensor with a Dynament one?

The Platinum series was designed as a direct replacement for the pellistor, but compatibility depends on the format, the connections and the voltage. We check starting from the existing sensor and the instrument model, because adaptations may be needed. Send the old code and a photo of the instrument.

What data should I send for a quotation on FGD fixed detectors?

Send the gas, the range, the area classification (ATEX or IECEx), the enclosure material (aluminium or stainless steel), the relays needed and the output signal. FGD10A has 4–20 mA and three relays, in an Ex d IIC enclosure. With these data we choose between FGD4, FGD5/6, FGD10A, FGD10B and FGD14.

How do I request a Dynament quotation?

Send the Dynament code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Dynament (manufacturer documentation)