New Cosmos Electric supplier in Romania
For New Cosmos Electric we quote portable detectors XP-3368II-W and XA-4400II, detection heads PD-12II, KD-12II and PD-14, alarm units NV-120, UV-810 and NV-600HS, based on the gas, the range and the Ex zone.
Who is New Cosmos Electric and what does it make?
New Cosmos Electric is a Japanese manufacturer of gas detectors: portable instruments for combustible gases, oxygen and toxic gases, fixed detectors with a sensing head and alarm units for industrial installations, as well as instruments that measure bearing wear from the metal particles in grease or oil. The company develops, manufactures and services the instruments, from the sensor to the display unit, for factories, stations and sites where a gas leak or lack of oxygen calls for an immediate alarm.
The XP-3368II-W portable detectors measure combustible gases from ppm up to LEL (lower explosive limit) and oxygen in the same instrument, in an explosion-proof version, and the XA-4400II is a body-worn detector with two to four gases (combustibles, oxygen, hydrogen sulphide, carbon monoxide). For fixed installations there are the KD-12II and PD-12II detection heads with display, the PD-14 aspirated detector for hydrogen in Ex d IIB+H2 T4 and IP65 design, and the alarm units NV-120 for one point, UV-810 in a panel with up to 15 points and NV-600HS for hydrogen stations. The PD-12 and KD-12 hydrogen detectors have approvals as stated in the manufacturer's documentation.
In industrial maintenance, the instruments also cover bearing monitoring: the SDM-72 measures the metal particles in grease and the SDM-73 those in lubricating oil, before vibrations increase. The quotation starts from the gas, the measuring range, the type of installation (portable, fixed, aspirated or diffusion) and the explosion-protection requirement.
What do we supply from the New Cosmos Electric range?
| Product | Description |
|---|---|
| Portable detectors XP-3368II-W, XP-3360II, XP-3310II and XP-3340II | Explosion-proof portable instruments for combustible gases. The XP-3368II-W adds oxygen and covers ppm–LEL, the XP-3360II-W and XP-3360II work in ppm or ppm–LEL, the XP-3310II measures in LEL, and the XP-3340II in volume percent. |
| XA-4400II, XP-302M and XO-326IIs oxygen indicators | The XA-4400II is a body-worn detector with two to four gases, the XP-302M measures oxygen, combustible gas, hydrogen sulphide and carbon monoxide at the same time, and the XO-326IIs measures oxygen from 0 to 25 vol% with an operating life of about 15,000 hours. |
| Detection heads PD-12II, KD-12II, PD-14, KD-5 and PE-2 | Fixed detectors, aspirated (PD-12II, PD-14, PE-2) or diffusion (KD-12II, KD-5), for combustible, oxygen, toxic gases and hydrogen. The PD-14 is in Ex d IIB+H2 T4 design, with IP65, and the sensor is replaced as a unit. |
| NV-120, UV-810, NV-520 and NV-600HS — alarm units | The NV-120 is the compact single-point alarm, the UV-810 is panel-mounted with 3–15 points, the NV-520 connects up to 12 detectors for LPG, and the NV-600HS monitors gas leaks at hydrogen stations, with 2–12 points. |
Why New Cosmos Electric?
- Combustible gas and oxygen in the same portable instrument — the XP-3368II-W measures from ppm up to LEL, in an explosion-proof version
- Hydrogen detection for explosive atmospheres — the PD-12 and KD-12 have approvals as stated in the manufacturer's documentation, and the PD-14 has an explosion-proof version and IP65
- Modular alarm system — detection heads, V3 display units and the UV-810 panel with 3, 6, 9, 12 or 15 points are combined according to the application
- Units with a pre-filled, calibrated sensor — on the PS-7 and PS-8 the module is replaced without gas calibration at the installation site
- Bearing wear monitoring — the SDM-72 and SDM-73 assess the metal particles in grease and oil before vibrations increase
Which New Cosmos Electric codes and series are requested most often?
| Code | Description |
|---|---|
| XP-3368II-W | Portable detector for combustible gases ppm–LEL and oxygen |
| XP-3360II-W | Portable detector for combustible gases, ppm–LEL |
| XP-3310II | Portable detector for combustible gases, LEL |
| XP-3340II | Portable detector for combustible gases, vol% |
| XP-702IIIS | Portable detector for combustible gas leaks |
| XA-4400II | Body-worn detector with 2–4 gases |
| XP-302M | Four-gas detector: oxygen, combustible, H₂S, CO |
| XO-326IIs | Digital oxygen indicator, 0–25 vol% |
| PD-12II | Aspirated detection head with display |
| KD-12II | Diffusion detection head with display |
| PD-14 | Aspirated detector for hydrogen, Ex d IIB+H2 T4, IP65 |
| NV-120C | Compact single-point alarm, combustible gases |
| UV-810 | Panel-mounted detection and alarm system, 3–15 points |
| NV-520 | Multi-point alarm for LPG, up to 12 detectors |
| NV-600HS | Multi-point alarm for hydrogen stations, 2–12 points |
| SDM-72 | Meter for metal particles in grease |
Where is New Cosmos Electric equipment used?
- Chemicals and petrochemicals — detection of combustible and toxic gases in installations
- Hydrogen stations and hydrogen installations — hydrogen alarm in Ex zones
- Confined spaces and sites — oxygen, hydrogen sulphide and carbon monoxide before entry
- Semiconductor industry — detectors for process gases such as arsine, phosphine and silane
- Industrial maintenance — monitoring bearing wear through the metal particles in grease and oil
How do we supply New Cosmos Electric in Romania?
From New Cosmos we can quote portable detectors from the XP-33, XP-3000 and XA series, oxygen indicators, PD and KD detection heads and NV, UV and V3 alarm units. They are supplied to order, usually in 1–4 weeks; multi-point systems can take longer, depending on the specification. In the request, it helps to include the gas to be detected and the measuring range, the Ex zone (with group), the number of points, the type of installation, the output required (relay or 4–20 mA) and the code on the existing detector.
The Ex marking and the measuring range of a detector are confirmed on the exact version, because not all models carry the same certifications.
Frequently asked questions about New Cosmos Electric
What does New Cosmos Electric make?
New Cosmos Electric makes portable and fixed gas detectors, alarm units, oxygen indicators, hydrogen detectors and environmental monitors, plus instruments for measuring bearing wear from metal particles. The company is Japanese and develops, manufactures and services its instruments itself.
How do I choose between an aspirated and a diffusion detector?
The diffusion detector (KD) measures the gas that reaches the sensor naturally and is installed in the hazardous area, while the aspirated one (PD, PE) draws the sample with a pump, so the flow needs to be checked. Tell us the gas, the distance and the Ex zone, and we check the suitable type.
Do you supply New Cosmos detectors in Romania, and how fast?
Detectors are supplied to order, usually in 1–4 weeks; some items can ship in 24–72 h when the item is in stock, locally or at the supplier. For multi-point systems or those with special certifications the lead time can be longer and is stated in the quotation.
How do I find out whether a current detector can take the place of an old New Cosmos one?
We start from the full code, the gas detected, the range, the type of installation and the output to the alarm unit. With the detector nameplate and the model of the alarm unit, we check with the supplier whether the current version keeps the connection and the signal; compatibility is confirmed after that answer.
What data should I send for a quotation on an NV-600HS or UV-810 alarm system?
Send the number of detection points, the gas or gases monitored, the measuring range (from ppm to LEL), the Ex zone, the length of the cables to the detectors, the outputs required to the control system and the available power supply. With this data we determine the panel configuration.
How do I request a New Cosmos Electric quotation?
Send the New Cosmos Electric code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: New Cosmos Electric Co., Ltd. (manufacturer documentation)