NIVUS supplier in Romania
Ultrasonic flowmeters for pipes and channels, level and software
Founded in 1967 · Headquarters: Eppingen, Germany
Who is NIVUS and what does it make?
NIVUS is a German manufacturer of flow and level measuring instruments for water, wastewater and industry, headquartered in Eppingen. The company was founded in 1967 and presents itself as a supplier of measuring systems and software solutions for process engineering, with more than 50 years of experience in the water sector. The range starts from ultrasonic and radar flowmeters and extends to hydrostatic level, water quality sensors, rain gauges and the NICOS and NIVUS Webportal software platforms.
Its speciality is partially filled pipes, open channels and sewers, where classic electromagnetic flowmeters do not work. The transmitters of the NivuFlow family are combined with cross-correlation sensors (CS2, CSM, POA), Doppler (KDA), radar (OFR) or, for full pipes, with NIC clamp-on ultrasonic sensors and sensors for pipes of up to 5000 mm, on the transit time difference principle. The company uses ultrasonic cross-correlation technology.
In Romania, NIVUS products appear in wastewater treatment plants, sewer networks, water supply mains and small hydropower plants, often supplied through integrators. For replacement, what matters is the transmitter model, the sensor type and the cable length, not just the pipe diameter. That is why the correct request starts from the nameplates in the field. In a request, the transmitter and sensor model from the nameplate shortens the identification of the part.
What do we supply from the NIVUS range?
| Product | Description |
|---|---|
| NivuFlow 750 | Flow transmitter presented for both partially filled and full pipes, with correlation, Doppler or transit time sensors; there is also a portable version (Mobile 750). |
| NivuFlow 600 | Transmitter for full pipes with ultrasound, also available in mobile variants (Mobile 600) and with the Wireless Transit Time (WTT) system. |
| NivuFlow 550 and 650 | Flowmeters for partially filled pipes and channels, for stationary or portable measurement (NivuFlow Mobile 550 and 750). |
| OCM F | Flowmeter for measurement in open channels and partially filled pipes, listed in the NIVUS range of flowmeters for liquids. |
Why NIVUS?
- Measurement in partially filled pipes and channels — where classic electromagnetic flowmeters are not applicable
- Ultrasonic cross-correlation — in-house technology, for velocity profiles in dirty media
- NIC clamp-on sensors — retrofit without interrupting the pipe, for drinking water networks
- Extensive sensor range — CS2, CSM, POA, KDA, NOS, NIS, NIC and OFR, depending on the pipe or channel
- Software and remote data — NICOS and Webportal for transmitting and analysing measurements
Which NIVUS codes and series are requested most often?
| Code | Description |
|---|---|
| NivuFlow 750 | Flow transmitter for partially filled and full pipes |
| NivuFlow 7550 | Flow transmitter from the NivuFlow family |
| NivuFlow 550 | Flow transmitter for partially filled pipes |
| NivuFlow 650 | Flow transmitter for partially filled pipes |
| NivuFlow 600 | Transmitter for full pipes |
| NivuFlow Mobile 750 | Portable flowmeter |
| NivuFlow Stick | Mobile system for flow in flowing waters |
| OCM F | Flowmeter for open channels |
| CS2 | Cross-correlation sensor |
| CSM | Cross-correlation sensor |
| KDA | Doppler sensor |
| NIC | Clamp-on sensor |
| OFR | Radar flow sensor |
| NICOS | Remote monitoring software system |
Where is NIVUS equipment used?
- Sewer networks — measurement in sewers and channels
- Wastewater treatment plants — inlet, outlet, return sludge
- Water supply — supply mains and distribution networks
- Hydropower — penstocks and streams
- Industry — process water and dirty water
How do we supply NIVUS in Romania?
From the NIVUS range we can prepare quotations for NivuFlow transmitters, flow and level sensors, mounting accessories and, where needed, spare parts for existing installations. Parts are supplied to order, usually in 1–4 weeks; systems configured for the application may need longer. For a quotation we need the transmitter and sensor model from the nameplate, the cable length, the diameter or the cross-section of the channel, the fluid type (clean water, wastewater), the Ex zone requirements and the outputs needed. The lead time is confirmed in the quotation.
Whether an existing sensor can be used with a new transmitter is established after checking the series and the version of both.
Frequently asked questions about NIVUS
What does NIVUS make?
NIVUS, founded in 1967 in Eppingen, makes ultrasonic and radar flowmeters for pipes and channels, level and water quality instruments, rain gauges and monitoring software. The main applications are water, wastewater and industry.
How do I choose between cross-correlation and transit time?
Cross-correlation is used in partially filled pipes and channels with dirty water, and transit time (the transit time difference) in full pipes. The choice depends on the degree of filling and the cleanliness of the fluid; send us the pipe data.
Do you supply NIVUS equipment in Romania, and how quickly?
Yes, NIVUS equipment is ordered; the lead time is usually 1–4 weeks, except for configurations with special sensors, where it may be longer. The exact lead time is confirmed in the quotation.
Can I replace only the transmitter and keep the existing sensors?
Sometimes yes, but it depends on the sensor series and the transmitter generation. Compatibilities are confirmed on data, not from memory. Send the nameplates of both components and a photo of the installation.
What data do you need for a NIVUS flowmeter quotation?
The diameter or shape of the channel, the minimum and maximum water level, the fluid type, the cable length to the sensor, the Ex requirements and the outputs wanted. For replacements, also include the models from the nameplates.
How do I request a NIVUS quotation?
Send the NIVUS code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: NIVUS GmbH (manufacturer documentation)