Raytech supplier in Romania
Transformer test instruments (winding resistance, transformation ratio), automatic test systems
Founded in 1995 · Headquarters: Bremgarten, Switzerland
Who is Raytech and what does it make?
Raytech is a Swiss manufacturer based in Bremgarten, active since 1995, that makes electrical test instruments, including for power and distribution transformers. The range covers three technical areas: winding resistance measurement (WR series), checking the transformation ratio and vector group (TR and T-REX series) and automatic multifunction diagnostic systems (ATOS). Raytech offers instruments for the routine electrical tests at the acceptance and periodic overhaul of a transformer.
What sets Raytech apart is the power of its integrated DC sources: the WR50 and WR100 series deliver up to 100 A at 50 V for measuring the winding resistance of high-power units, where instruments with lower currents would need excessively long stabilisation times. The TR-MARK III system automatically detects the vector group on three-phase transformers, while the ATOS family combines several tests in a single unit, with automatic multiplexing.
For the Romanian market, the Raytech range makes sense for electrical test laboratories, for network operators that carry out periodic overhauls of power transformers, and for transformer manufacturers or repairers that check every unit before delivery.
What do we supply from the Raytech range?
| Product | Description |
|---|---|
| WR Series: Winding Resistance Measurement | Portable instruments for measuring transformer winding resistance, with versions from 15 A (WR14) up to 100 A (WR100-13R), on 2 or 3 channels simultaneously, battery or mains powered, for fast acceptance or overhaul tests. |
| TR and T-REX Series: Transformation Ratio | Instruments for checking the transformation ratio and vector group, from simple single-phase models (TR-1) up to three-phase systems with automatic vector detection (TR-MARK III), complemented by the T-REX extension for simultaneous measurement on three phases. |
| ATOS / mini-ATOS: Automatic Diagnostic Systems | Multifunction systems that combine several tests in one instrument, with automatic multiplexing, designed for complete transformer diagnosis in a single site visit. |
Why Raytech?
- DC sources of up to 100 A at 50 V (WR100 series): fast winding resistance measurement on high-power transformers
- Automatic vector group detection: TR-MARK III removes manual phase vector checking
- ATOS multifunction systems: combine several tests in one instrument, with automatic multiplexing
- T-REX three-phase measurement extension: complements single-phase ratio instruments for complete tests on all three phases
Which Raytech codes and series are requested most often?
| Code | Description |
|---|---|
| WR14 | Winding resistance measurement, 15 A, 2 channels |
| WR14R | Rack version of the WR14, 15 A, 2 channels |
| WR50-12 | Resistance measurement, 50 A, 2 channels |
| WR50-13 | Resistance measurement, 50 A, 3 channels |
| WR50-12R | WR50 rack version, 2 channels |
| WR50-13R | WR50 rack version, 3 channels |
| WR100-12R | Resistance measurement, 100 A, 2 channels, rack |
| WR100-13R | Resistance measurement, 100 A, 3 channels, rack |
| TR-1 | Transformation ratio check, single-phase |
| TR4 | Three-phase transformation ratio, test voltage up to 250 V |
| TR-MARK III 250V | Automatic three-phase vector group detection |
| TR-MARK III R 250V | Rack version of the TR-MARK III |
| T-REX | Three-phase extension for simultaneous measurement on 3 phases |
| T-REX R | Rack version of the T-REX extension |
| mini-ATOS | Portable multifunction transformer diagnostic system |
| ATOS | Automatic system for complete transformer diagnosis |
| MUX-R | Multiplexer for extending test channels |
| ISU-R | Accessory for resistance tests |
Where is Raytech equipment used?
- Electric power: periodic overhauls of network transformers
- Transformer manufacturers: final testing before delivery
- Electrical test laboratories: resistance and ratio tests
- Transformer repairers and workshops: diagnosis before and after intervention
How do we supply Raytech in Romania?
We supply Raytech transformer test instruments on the basis of the manufacturer's technical documentation, and availability is checked on each request. We bring the equipment in to order, usually in 1–4 weeks, depending on the exact configuration requested by the customer. For an accurate quotation, a laboratory or maintenance engineer should send us the power of the transformer under test, the number of channels needed and whether they want a single-phase system or a complete three-phase package. Calibration certificates for these instruments, when required, are obtained on request through the manufacturer or from an accredited laboratory.
The compatibility of an older reporting software with current Raytech firmware versions is checked case by case.
Frequently asked questions about Raytech
What products does Raytech make?
Raytech makes Swiss instruments for testing power transformers: winding resistance instruments, transformation ratio instruments with automatic vector group detection, and ATOS automatic systems that combine several tests in a single field instrument.
How do I choose a Raytech winding resistance instrument by current?
Choose the DC source current according to the transformer power: the WR14 series at 15 A is sufficient for small units, while high-power transformers need the WR50 or WR100 for a reasonable stabilisation time. Send us the power and type of the transformer for the right recommendation.
What is the Raytech WR series?
The WR series comprises winding resistance measuring instruments, with versions from 15 A to 100 A and with 2 or 3 channels.
Can you supply Raytech equipment in Romania, and what is the lead time?
Yes, to order, usually in 1–4 weeks, depending on the model and on confirmation from the Swiss factory for the configuration your laboratory requires.
What details should I specify for a Raytech ATOS system quotation?
Specify the type of transformer under test (single-phase or three-phase), the test voltage required and whether you need the MUX-R multiplexer to extend the number of channels, so that the quotation can be configured correctly before it is sent.
How do I request a Raytech quotation?
Send the Raytech code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Raytech AG (manufacturer documentation)