Meatest supplier in Romania
Multi-product calibrators, power/energy calibrators, process calibrators, impedance standards
Founded in 1991
Who is Meatest and what does it make?
Meatest is a Czech manufacturer of electrical calibrators, founded in 1991 starting from individual requests for custom metrology instruments. The range covers AC/DC multifunction calibrators for multimeters and energy meters, DC precision calibrators for process signals, power and energy calibrators, resistance and capacitance decade boxes, and impedance standards for calibrating LCR meters. From the Meatest product line we can quote both portable calibrators for small laboratories and precision systems for accredited metrology laboratories.
What sets Meatest apart is its wide accuracy coverage within the same family of multifunction calibrators: the 9000 series starts at 35 ppm on the base model (9010) and rises to 9-10 ppm on the 9010+ and 9020 variants, allowing a laboratory to choose the accuracy that fits its budget without changing manufacturer. The M160 and M160i process DC calibrators work at 20 ppm, and the M160 includes RTD and resistance sources, useful for calibrating industrial process multimeters. The M632 and M642 decade boxes cover resistance ranges from 100 mΩ to 22 MΩ, with resolutions in the microohm range, for simulating RTD sensors or reference resistors.
For the Romanian market, Meatest makes sense at accredited metrology laboratories, measuring instrument service centres and energy or telecom companies that must periodically calibrate multimeters, meters or LCR meters.
What do we supply from the Meatest range?
| Product | Description |
|---|---|
| 9000 Series Multifunction Calibrators | The 9010, 9010+ and 9020 are AC/DC calibrators for multimeters and energy meters, with accuracy from 35 ppm on the base model to 9 ppm on the 9020, and a modular design on the 9010+ for later expansion. The 9000 is the portable version, at 11 kg, with outputs of up to 1050V and 20.5 A, plus simulated resistance and capacitance. Typical application: calibrating digital multimeters and energy meters in a laboratory or directly in the field with the portable unit. |
| M160 / M160i Process DC Calibrators | Process DC signal calibrators with 20 ppm accuracy, with current, voltage and resistance source and measurement and RTD simulation, designed for calibrating process multimeters and industrial evaluation units. The customer must specify the type of signal being calibrated (current, voltage, RTD) and the accuracy required by the calibration procedure. |
| Decade Boxes and Impedance Standards | The M632, M642, M631 and M641 are resistance decade boxes, with or without RTD simulation, while the M194 covers high resistances up to 6kV and the M525 covers programmable capacitance between 100pF and 100µF. The M550 is an impedance calibrator with a bank of fixed standards for automatic calibration of LCR meters up to 1 MHz. Typical application: calibrating ohmmeters, multimeters and LCR meters in a metrology laboratory. |
Why Meatest?
- A family of multifunction calibrators with accuracy from 35 ppm to 9-10 ppm, depending on the laboratory's budget
- Process DC calibrators with RTD and resistance simulation, at 20 ppm accuracy
- Resistance and capacitance decade boxes for metrology laboratories
- Impedance standards covering ranges from below 100 Hz to 1 MHz
- More than three decades of making metrology instruments, starting from custom laboratory requests
Which Meatest codes and series are requested most often?
| Code | Description |
|---|---|
| 9020 | AC/DC multifunction calibrator, 9 ppm accuracy |
| 9010+ | Modular multifunction calibrator, 10 ppm accuracy |
| 9010 | Multifunction calibrator, 35 ppm accuracy |
| 9000 | Portable multifunction calibrator, 11 kg |
| M160 | Process DC calibrator, 20 ppm accuracy |
| M160i | Process DC calibrator, 20 ppm accuracy |
| M133C 3F | Three-phase power calibrator with power quality functions |
| M133C 1F | Single-phase power calibrator |
| M133Ci 3F | Three-phase power calibrator for transducers |
| M133Ci 1F | Single-phase power calibrator for transducers |
| M192 | True resistive load, 3000W |
| M192A | True resistive load, 3000W |
| M632 | Resistance decade box, 1Ω-1.2MΩ |
| M642 | Resistance decade box, 100mΩ-22MΩ |
| M631 | RTD and resistance simulator, 0.01°C accuracy |
| M641 | RTD and resistance simulator, 5W |
| M194 | High resistance decade box, up to 6kV |
| M525 | Programmable capacitance decade box |
| M550 | Impedance calibrator, bank of fixed standards |
| MTE Laboratory Standards | Resistance, capacitance and inductance decade standards |
Where is Meatest equipment used?
- Metrology and calibration — accredited laboratories calibrating multimeters and meters
- Power and utilities — calibration of meters and measuring instruments in the network
- Telecommunications — calibration of LCR meters and impedance standards
- Electronics — automated testing and calibration at production stations
How do we supply Meatest in Romania?
For Meatest we work from the specifications in the manufacturer's technical documentation. We supply Meatest calibrators to order, usually in 1–4 weeks depending on the model and the accuracy requested. For a quotation, the customer needs to send the model required (for example 9010+ or M160), the accuracy required by the calibration procedure and the signal range needed. We do not keep this range on the shelf; each calibrator is ordered for the laboratory's exact need.
The initial calibration of Meatest calibrators is carried out at an accredited laboratory, and servicing of the range is handled by the manufacturer.
Frequently asked questions about Meatest
What product range does Meatest have?
Meatest makes electrical calibration equipment: AC/DC multifunction calibrators, process DC calibrators, power and energy calibrators, resistance decade boxes and impedance standards. The company is Czech, active since 1991 in the production of metrology instruments.
How do I choose a Meatest calibrator for a metrology laboratory?
The choice starts from the accuracy required by the calibration procedure: for high accuracy, the 9020 or 9010+ series cover multimeters and energy meters; for process signals (current, voltage, RTD), the M160 or M160i are the dedicated calibrators. The daily test volume also influences the choice between a portable and a bench version.
What does Meatest offer for calibrating LCR meters?
The M550 is the Meatest impedance calibrator with a bank of fixed standards for automatic calibration of LCR meters up to 1 MHz, while the MTE series offers individual decade standards of resistance, capacitance and inductance for manual calibration.
Can you supply Meatest calibrators in Romania, and how quickly?
We supply Meatest calibrators to order, usually in 1–4 weeks, depending on the model and the accuracy required. The range is supplied to order.
How do I request a Meatest quotation?
Send the Meatest code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Meatest s.r.o. (manufacturer documentation)

