Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Optomet supplier in Romania

For Optomet we quote the SMART Single+, SMART Scan+ and 3D-Scan vibrometers, the CLASSIC Nova, Fiber, Scan and Vector vibrometers and the SMART Lab software, depending on the measured surface, the working distance and the frequency band.

Founded in 2004 · Headquarters: Darmstadt, Germany

Request a quote

Who is Optomet and what does it make?

Optomet is a German company from Darmstadt, founded in 2004, that develops and makes laser Doppler vibrometers for non-contact measurement of mechanical vibration. A laser vibrometer measures not only the frequency and amplitude but the whole signal over time, including the phase, with no added mass on the part and no cables, which matters for lightweight structures, hot parts or moving parts. The displacement resolution reaches 50 fm (femtometres), and the frequency band runs from direct current up to 50 MHz for the SMART series and up to 25 MHz for the CLASSIC series.

The SMART series combines the vibrometer, the data acquisition and the signal generator in a single instrument: SMART Single+ for one point, SMART Scan+ with scanning and a 7-inch touchscreen, SMART 3D-Scan with three synchronised laser heads, SMART Full Body with several instruments around the object, and the Multi-Fiber and 3D-Fiber fibre versions, all with the SMART Lab software. The CLASSIC series has vibrometers with a 633 nm helium-neon (HeNe) laser (Vector, for reflective surfaces, underwater measurements and small spots) and with a 1550 nm near-infrared laser (Nova, Nova-Xtra, Fiber and Scan), which measure on dark, rough or incandescent surfaces without preparation. The infrared lasers are safety class 1, so they do not require protective goggles.

Such instruments are of interest to the vibration laboratories of automotive component, turbine and aerospace manufacturers, to electronics laboratories, where the vibration of circuit boards is measured, and to institutes that validate finite element models. The choice depends on the surface, the working distance, the frequency band and the number of points, which is why the quotation starts from the part measured and the existing instrument.

What do we supply from the Optomet range?

ProductDescription
SMART Single+ and SMART Scan+Laser Doppler vibrometers with integrated data acquisition and signal generator: Single+ for single-point measurements, easy to carry, Scan+ with scanning, a 7-inch touchscreen and the option of extension to a 3D system, controlled from the SMART Lab software.
SMART 3D-Scan and SMART Full BodyThree-dimensional vibration systems: 3D-Scan uses three synchronised heads for whole surfaces, and Full Body places several Scan+ instruments around the object, to see the vibration from all angles.
CLASSIC Nova, Fiber and ScanVibrometers with a 1550 nm SWIR laser: Nova with a free beam, Fiber with small optical heads on a fibre, for tight spaces, and Scan, with a large optical aperture, for measurements on almost any surface, without preparing it.
CLASSIC VectorEntry-level vibrometer, with a 633 nm HeNe laser, for surfaces with good reflection, measurements through water and very small structures, where the size of the laser spot matters; a version with optics for microstructures is also available.

Why Optomet?

  • Non-contact measurement with no added mass — suited to lightweight structures, hot or moving parts, where accelerometers change the result
  • Displacement down to 50 fm — frequency band from direct current to 50 MHz for the SMART series, from microstructures to parts of over 10 m²
  • 1550 nm near-infrared laser — the Nova and Fiber series measure on dark, rough or incandescent surfaces, without reflective tape
  • 3D scanning vibrometers — SMART 3D-Scan uses three synchronised heads, with over 30 reference channels and 24 generator channels
  • Class 1 near-infrared (SWIR) laser — no protective goggles, with working distances from a few millimetres to over 300 m

Which Optomet codes and series are requested most often?

CodeDescription
SMART Single+Single-point laser vibrometer with integrated acquisition
SMART Scan+Scanning vibrometer, 7-inch touchscreen
SMART 3D-Scan3D scanning system with three synchronised heads
SMART Full Body3D system with several instruments around the object
SMART Multi-FiberSMART vibrometer with several fibre heads
SMART 3D-Fiber3D vibrometer with fibre heads
SMART DAQData acquisition system for vibrometers
SMART LabControl, acquisition and analysis software
CLASSIC Vector633 nm HeNe vibrometer, single point
CLASSIC Nova1550 nm SWIR vibrometer, free beam
CLASSIC FiberSWIR vibrometer with fibre optical heads
CLASSIC Fiber-MultiplexFibre vibrometer with optical switch for several points
CLASSIC ScanScanning SWIR vibrometer, large aperture

Where is Optomet equipment used?

  • Automotive and mechanical — brake discs, rotating parts and lightweight structures
  • Energy and turbines — turbine blades and discs, measurements from a distance
  • Aerospace — aircraft structures in a wind tunnel
  • Electronics — vibration of printed circuit boards
  • Research — validation of finite element models through scanning vibrometry

How do we supply Optomet in Romania?

We can quote Optomet laser vibrometers from the SMART and CLASSIC series, with free-beam or fibre heads, supplied to order. The lead time is usually 1–4 weeks to order, and depending on the specification it can be longer for 3D scanning systems. For a quotation send us the surface type (glossy, dark, hot, wet), the working distance, the frequency band and the maximum vibration velocity, the number of points to be measured, whether you need 2D or 3D scanning and the model of the existing vibrometer, if you are extending it. The exact lead time is confirmed in the quotation.

The HeNe or SWIR laser is recommended once we know the surface type, the working distance and the frequency band.

Frequently asked questions about Optomet

What does Optomet make?

Optomet, from Darmstadt, makes laser Doppler vibrometers for non-contact vibration measurement: single-point, scanning and three-dimensional instruments, with a HeNe or near-infrared laser, plus the SMART Lab software. They are used in industry, research and development.

When do I choose a vibrometer with a SWIR laser instead of a HeNe one?

The 1550 nm SWIR laser measures on dark, rough, incandescent or fibre surfaces, without reflective tape. The 633 nm HeNe laser is chosen for reflective surfaces, measurements through water or very small spots. Send us the surface and the distance for a recommendation.

Do you supply Optomet vibrometers in Romania, and how fast?

Yes, supplied to order, usually in 1–4 weeks; depending on the specification, the lead time can be longer, especially for 3D systems with several heads. The exact lead time is confirmed in the quotation, based on the application data.

Can I extend an existing Optomet vibrometer with scanning or a fibre head?

This can be checked on the basis of the model and series of the instrument, the software version and the interfaces. The Scan+ can be extended to a 3D system, and a fibre head can serve as a reference, and compatibility is confirmed after comparing the nameplate data.

What should I send for a quotation on a laser vibrometer?

Send the object measured and its surface, the working distance, the frequency band, the maximum vibration velocity, the number of points and whether you measure at a single point, over a surface or in 3D. The environment also matters: humidity, water between the instrument and the object, or a high temperature of the part.

How do I request a Optomet quotation?

Send the Optomet code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Optomet GmbH (manufacturer documentation)