Air conditioning systems
An air conditioning system keeps the temperature and, at times, the humidity of a space at a controlled level, using split units, multi-split units or VRF systems that serve several rooms from a single outdoor unit. It is used in offices, commercial spaces and industrial areas with thermal comfort requirements.
A split system has one outdoor and one indoor unit, suitable for a single room; multi-split connects several indoor units to a single outdoor unit, for a few zones with independent control; the VRF (variable refrigerant flow) system extends this principle to whole buildings, with dozens of indoor units and the possibility of recovering heat between zones that cool and those that heat at the same time. Capacity is sized according to the real thermal load of the space, not only the floor area, taking into account orientation, insulation, occupancy and heat gains from equipment. A system suited to commercial or industrial spaces has a refrigerant with low environmental impact, high energy efficiency at part load (where it operates most of the time), and the possibility of zone control, so as not to condition evenly spaces with uneven occupancy. The noise level of the indoor units in occupied spaces also matters, as do the maximum permitted length of the refrigerant piping runs to the outdoor unit and integration with a building management system, where one exists.
How to choose
Real thermal load of the conditioned space
It is calculated from floor area, height, insulation, orientation and internal heat gains (equipment, occupancy), not estimated only from square metres, a frequent mistake that leads to over- or undersizing.
System type: split, multi-split or VRF
A split is enough for a single room, multi-split covers a few independent zones, and VRF becomes economically justified in large buildings with many zones and the possibility of heat recovery between them.
Number of zones needing independent control
Zones with different orientation or occupancy need separate temperature control, which directly influences the architecture of the chosen system.
Length and configuration of the refrigerant piping runs
The distance between the outdoor unit and the indoor ones has a maximum limit allowed by the manufacturer, which can restrict the possible placement of the equipment.
Energy efficiency at part load
The system operates most of the time at part load, not at maximum capacity, so efficiency in this regime matters more for operating cost than performance at peak load.
Noise level allowed in the occupied space
Offices and commercial spaces have stricter noise requirements than industrial halls, which can influence the choice of indoor unit type.
Possibility of integration with the building management system
Where a building automation system already exists, protocol compatibility simplifies integration and monitoring of energy consumption.
What to send for a quotation
- Floor area and height of the space, plus the orientation and insulation of the building
- Number of zones needing independent temperature control
- Internal heat gains (equipment, occupancy, lighting)
- Estimated distance between the desired location of the outdoor and indoor units
- Noise requirements for the indoor units
- Desired delivery and commissioning date
Typical applications
- Offices
- Shopping centres
- Hotels
- Industrial spaces
- Server rooms and technical spaces
Maintenance and spare parts
The filters of the indoor units become clogged with dust and must be cleaned periodically, otherwise airflow drops and energy consumption rises. Periodic checks are recommended for the refrigerant level, cleaning the outdoor unit's heat exchanger of dust and leaves, and checking the condensate drain, especially before the warm season, when the system works at maximum load.
Brands we quote for this product type
Frequently asked questions
What is the difference between a multi-split system and a VRF one?
Multi-split connects a few indoor units, usually up to eight, to a single outdoor unit, suitable for a home or a small office. A VRF system supports dozens of indoor units on an extended network of refrigerant pipes and can recover heat between zones that cool and those that heat at the same time, which is justified in large buildings.
How is an air conditioning system correctly sized for a commercial space?
The real thermal load is calculated from floor area, insulation, orientation and the internal heat gains from equipment and occupancy, not only from square metres. The number of zones with independent control then influences the choice between split, multi-split or VRF.
What should be sent for an air conditioning system quotation, and how long does delivery take?
The area and characteristics of the space, the number of zones wanted and the internal heat gains. Delivery is to order, typically 1–4 weeks, depending on the manufacturer and on the complexity of the VRF configuration, if applicable.
Can a VRF system later be extended with additional indoor units?
Usually yes, within the nominal capacity of the installed outdoor unit; extension beyond this limit requires an additional outdoor unit or replacing the existing one with one of higher capacity.