Encoders and Position and Angle Transducers
A rotary encoder converts the movement of a shaft into an electrical signal that indicates position, speed or direction of rotation, while a linear transducer does the same for a movement in a straight line. Together they give the controller the position information needed by servo motors, positioning axes, cranes, packaging machines and machining equipment, either as pulses or as an absolute value transmitted digitally. The choice depends on the accuracy required, the controller interface and the environmental conditions.
An incremental encoder emits pulses on two channels, A and B, shifted by a quarter of a period, which lets the controller also determine the direction of rotation; a reference channel Z gives one pulse per revolution. Position is obtained by counting pulses, so after a power failure the axis must be returned to the reference point. An absolute encoder assigns a unique code to each shaft position, so the correct value is available immediately after start-up, and multiturn versions add a mechanism that also counts complete revolutions.
Reading can be optical, magnetic or inductive. The optical version offers high resolution but copes less well with oil, condensation and dirt, while the magnetic one tolerates dust and vibration better. For linear movements, potentiometric, LVDT-type inductive, magnetostrictive or magnetic tape transducers are used, and for angles, contactless angle sensors (magnetic or inductive) or, in difficult environments, resolvers. The interface - pulses, analogue signal, synchronous serial bus or fieldbus - must match the input of the controller you have.
How to choose
Incremental or absolute
Incremental is enough when the axis has a referencing procedure at start-up anyway; absolute is chosen when the position must be kept after a power failure or when reference-seeking movements are not acceptable.
Resolution and accuracy needed
Resolution tells how many distinct positions can be read, accuracy tells how close to the real value the reading is; a high resolution does not compensate for poor mechanical accuracy of the mounting.
Shaft type and fixing
Encoders with solid shaft, hollow shaft or mounting flange require different installations; choose by shaft diameter and by the permitted play, so as not to introduce errors through the connecting coupling.
Electrical and communication interface
Check whether the controller input accepts TTL or HTL differential signals, sine-cosine signals, an analogue output or a serial bus; the supply voltage must also match.
Speed and maximum output frequency
At high speeds, the pulse frequency can exceed what the counting input accepts; calculate the product of resolution and speed before fixing the number of pulses per revolution.
Operating environment
Temperature, vibration, shock, dust, oil and moisture dictate the IP protection rating and the reading technology; with strong shocks or heavy contamination, magnetic reading usually tolerates the conditions better.
Linear strokes and measuring length
For linear transducers, the useful stroke is chosen with a mechanical margin, and the construction type - rod, profile or tape - is matched to the available space and the mounting direction.
What to send for a quotation
- Type of measurement: rotation, linear displacement or limited angle
- Incremental or absolute encoder, single-turn or multiturn
- Desired resolution and the accuracy required by the application
- Interface accepted by the controller and the supply voltage
- Shaft size or linear stroke and the mounting type
- Environmental conditions: temperature, dust, oil, vibration
Typical applications
- Servo motors and positioning axes
- Cranes, overhead cranes and lifts
- Packaging and machining machines
- Hydraulic presses and injection moulding machines
Maintenance and spare parts
Encoders have no spare parts in the classic sense, but they fail from external causes: a rigid coupling that transmits shocks, a worn downstream bearing, a shielded cable poorly grounded or a damaged seal. Check periodically the mechanical fixing, the condition of the cable and the shield connection, because electrical noise produces false counts that are hard to trace. With linear transducers, watch for wear of the slider or the float and clean the guiding surface.
Brands we quote for this product type
- ASM Automation Sensorik Messtechnik
- ATEK Sensor Technologies
- BEGE
- Capacitec
- Contelec
- DIS Sensors
- Dynapar
- Elap
- elobau
- Eltra
- Encoder Products Company
- Fagor Automation
- Fiama
- Gurley Precision Instruments
- Heidenhain
- Hengstler
- Hohner Automation
- Johannes Hübner Giessen
- Kübler
- Leine & Linde
- Lenord, Bauer & Co.
- Lika Electronic
- Lion Precision
- Micro-Epsilon
- Nemicon
- Novotechnik
- Opkon
- POSITAL FRABA
- Renco Encoders
- Sakae
- Scancon
- Selet
- Siko
- Temposonics
- TR Electronic
- US Digital
- VAHLE
- Wachendorff
- WayCon Positionsmesstechnik
- Westlock Controls
Frequently asked questions
What is the difference between an incremental and an absolute encoder?
The incremental encoder counts pulses from a starting point, so it loses its position when the power is switched off and needs referencing. The absolute encoder sends a unique value for each shaft position, available immediately after restart, which makes it suitable for axes that cannot be moved to a reference point. The drawback is more complex electronics and a digital interface, and the choice is made according to the restart requirement and the controller inputs.
How do I choose the number of pulses per revolution?
Start from the minimum movement you need to detect: divide the travel of one revolution by the desired resolution and you get the number of pulses required. Then check the resulting frequency at maximum speed, because the controller input has a counting limit. If the application requires very fine resolution at high speed, a sine-cosine signal interface or a high-resolution absolute encoder may be a more practical solution than multiplying pulses.
What data do I provide for a quotation for an encoder or a transducer, and how long does delivery take?
State the type of measurement, the resolution, the controller interface, the supply voltage, the shaft size or linear stroke, the mounting type and the environmental conditions. If you are replacing an existing device, the code on the nameplate is generally enough to start the quotation. Delivery is 24–72 h when the item is in stock, locally or at the supplier, and for made-to-order versions it typically takes 1–4 weeks; it can take longer depending on the brand and on the specifications.
Why does the controller show wrong positions even though the encoder is new?
Frequent causes are a coupling slipping on the shaft, a cable shield not connected properly, cable routes running parallel to power cables, and a difference between the signal type of the encoder and the one expected by the input. First check the mechanical fixing and the shield connection, then the signal levels with an oscilloscope or a diagnostic indicator. A position that drifts gradually can indicate a mechanical problem, for example coupling slip.
Updated: 2026-11-20