Calibrators and Calibration Equipment
A calibrator generates or measures a known reference signal - voltage, current, temperature or pressure - to check whether another measuring instrument indicates the correct value. It is the basic equipment of any metrology department or of any team that maintains transmitters and process instruments.
Process calibrators can work as a source, generating a known signal, for example 4-20 mA, to test an indicator or controller, or as a reference meter, reading the signal of a transmitter with an accuracy superior to that of the instrument being checked; many models combine both functions in one portable device. For temperature, calibration is carried out either with dry-block calibrators, which simulate an environment at controlled temperature, or with liquid calibration baths for wider ranges.
What distinguishes a good calibrator is traceability to a national or international standard, documented by a certificate, and the instrument's own measurement uncertainty, which must be several times smaller than the tolerance of the instrument being checked - otherwise the calibration has no metrological value. The stability of the calibrator over time and the recommended interval for its own recalibration are as important as the initial accuracy in the datasheet.
How to choose
Type of physical quantity to calibrate
Voltage, current, temperature or pressure call for different calibrators; some multifunction models cover several quantities, with accuracy compromises compared with a dedicated instrument.
Own accuracy versus the tolerance of the instrument checked
The usual rule requires the uncertainty of the calibrator to be at least four times smaller than the permitted tolerance of the instrument tested, for a meaningful calibration.
Traceability and calibration certificate
Check whether the instrument's certificate is issued by an accredited laboratory and whether the traceability chain to the national standard is clearly documented.
Source function versus meter function
A calibrator that can both generate and read the signal reduces the number of instruments needed in the field, useful for teams that travel frequently.
Calibration range required
For temperature blocks, check the range covered against the real working range of the sensors in the installation, including at the lower and upper limits.
Recalibration interval of the calibrator itself
The instrument used as a reference must be recalibrated periodically at an accredited laboratory, otherwise all calibrations made with it become questionable.
What to send for a quotation
- The physical quantity to calibrate: voltage, current, temperature or pressure
- The range required and the tolerance of the instruments to be checked
- Whether a source function, a meter function or both are needed
- Whether the calibration certificate must be issued by an accredited laboratory
- The number of instruments needed and the estimated frequency of use
Typical applications
- Checking transmitters and sensors
- Calibration of process instruments
- Internal metrological control
- Metrology laboratories
Maintenance and spare parts
The calibrator itself must be recalibrated periodically at an accredited laboratory, at the interval recommended by the manufacturer, so that the certificates issued with it remain metrologically valid. Connectors and test leads are checked for contact resistance, and the internal batteries are replaced at the first signs of reading instability, because a weak supply can affect the accuracy of the generated signal.
Brands we quote for this product type
- Additel
- AOIP
- ATEQ
- Beamex
- Calmet
- CLOU Electronics
- Dostmann electronic
- Druck (Baker Hughes)
- EPRO Gallspach
- ETALON AG
- Flow Management Devices
- Fluke
- Fluke Calibration
- Furness Controls
- GFUVE
- Greisinger
- Hangzhou Songyang
- ITECH
- Kingsine Electric Automation
- KLEIBER Infrared
- KoCoS
- MBW Calibration
- Meatest
- Mecmesin
- Mesa Labs
- MeterTest
- MTE Meter Test Equipment
- Radian Research
- Sika
- Time Electronics
- Transmille
- WIKA
- ZERA
Frequently asked questions
What is the difference between a calibrator and a precision multimeter?
A multimeter measures a value that already exists in the circuit, with an accuracy sufficient for routine checks. A calibrator, besides the reference measurement function, can also generate a known signal with high precision, traceable to a standard, in order to check whether another instrument indicates the correct value. The essential difference is the purpose: the multimeter reads the state of the installation, while the calibrator checks whether other measuring instruments are correct.
How do I choose the accuracy of calibrators relative to the instruments I check?
The basic rule in metrology is a ratio of at least 4:1 between the accuracy of the calibrator and the permitted tolerance of the instrument checked, sometimes even 10:1 for critical applications. If this ratio is not respected, the calibration uncertainty comes dangerously close to the tolerance of the instrument, and the result no longer has value for the conformity decision. When choosing, start from the strictest instrument you intend to check.
What do I send for a quotation for calibrators, and how long does delivery take?
State the physical quantity to calibrate, the range required and the tolerance of the instruments you will check, plus whether you need a source function, a meter function or both. Mention whether the calibration certificate must be issued by an accredited laboratory, because this requirement can influence the model recommended. The delivery time is typically 1–4 weeks on order, depending on the manufacturer.
Can a dry-block temperature calibrator replace a liquid calibration bath?
The dry block is quicker to use and needs no immersion liquid, but it typically has slightly poorer temperature uniformity and a narrower range of application than a liquid bath. For sensors of unusual shape or for very tight uncertainty requirements, the liquid bath remains the preferred choice. For quick, repeated field checks, the dry block is usually sufficient.