Level Transmitters
A level transmitter is an instrument that measures, continuously or at a point, the height of a liquid, a paste or a granular solid material in a tank, silo or basin, and sends the signal to a control or display system. It is used for inventory monitoring, overfill prevention and automatic control of pumps or feed valves.
The main technologies are hydrostatic measurement (the pressure of the liquid column, simple and robust for liquids), contact or non-contact radar (suitable for aggressive, foaming or high-temperature liquids, with no moving parts), ultrasonic (economical, but sensitive to foam, steam or dense dust), and capacitive or float sensors for point level, used mainly as safety limit switches. The choice of technology depends more on the properties of the measured medium than on the accuracy desired on paper.
A level transmitter suited to industrial use is recognised by the compatibility of the wetted materials (body, diaphragm, probe) with the measured fluid or product, by the protection class of the housing for the installation environment and by signal stability over time, not just the initial accuracy in the catalogue. For tanks with foam, agitation or dense vapours, guided wave radar technology is generally more stable than ultrasonic; for explosive atmospheres, ATEX 2014/34/EU certification of the probe and the electronics is mandatory.
How to choose
Type of medium measured
A clean liquid, a viscous paste or a granular solid each have more suitable technologies; choosing a sensor designed for clean liquids on a product with foam or deposits gives unstable readings.
Measuring range (the actual height of the tank)
The range of the transmitter must cover the total height of the tank, not just the normal operating level, otherwise overfilling or complete emptying can no longer be signalled correctly.
Conditions inside the tank
Foam, dense vapours, strong agitation or deposits on the walls directly influence the choice between radar, ultrasonic or hydrostatic; ignoring them leads to fluctuating readings even with an expensive sensor.
Compatibility of wetted materials with the product
The body, diaphragm or probe must resist the measured fluid or product chemically in the long term, not just on first contact; slow corrosion falsifies the readings before it becomes visible.
Output type and integration into the existing system
The 4-20 mA analogue output, the digital signal or the fieldbus protocol must match what the automation or the existing display in the installation accepts.
Certifications for explosive atmospheres
In fuel or volatile chemical storage, the probe and the electronics of the transmitter must be ATEX certified, with a protection class suited to the installation area.
What to send for a quotation
- Type of medium measured: liquid, paste or granular solid
- Total height of the tank or silo
- Conditions inside: foam, agitation, vapours or deposits
- Tank material and the chemical compatibility required
- Desired output type: 4-20 mA, digital or fieldbus
- Required quantity and desired delivery deadline
Typical applications
- Industrial tanks
- Silos
- Process basins
- Pumping stations
- Process water storage tanks
Maintenance and spare parts
With level transmitters, the main problems come from deposits on the probe or on the diaphragm, which can distort the reading over time, and from moisture entering poorly sealed electrical connections. Periodic checks of the reading against a manual control measurement are recommended, together with cleaning the probe for products that leave deposits and inspecting the sealing gaskets of the electronics housing.
Brands we quote for this product type
- Agar Corporation
- AMETEK Drexelbrook
- AMETEK Magnetrol
- Anderson-Negele
- APLISENS
- BAMO
- BD Sensors
- Berthold Technologies
- Bindicator
- BinMaster
- Binsack Reedtechnik
- CAMLogic
- CAPTRON
- Cesare Bonetti
- Chemitec
- Delta Instruments
- Delta Mobrey
- Dinel
- Dynatrol
- E.L.B. Füllstandsgeräte
- EGE-Elektronik
- Elettrotec
- elobau
- Endress+Hauser
- Euroswitch
- FAFNIR
- Fantini Cosmi
- Gems Sensors
- Gestra Flowserve
- Giacomello
- GOK
- Hawk Measurement
- Heron Instruments
- HollySys
- HT Hydrotechnik
- Hycontrol
- In-Situ
- JOLA
- Keller
- KEYENCE
- Klay Instruments
- Kobold
- KRIWAN
- Labkotec
- microsonic
- Mollet
- Monitor Technologies
- Moore Industries
- NIVELCO
- NIVUS
- NOSHOK
- Pulsar Measurement
- Rechner Sensors
- Reinhausen (MR / MESSKO)
- Rittmeyer
- Ronan Engineering
- Scully Signal Company
- SEBA Hydrometrie
- Sensys (Sensor System Technology)
- Siemens Instrumentation
- Sinomeasure
- Solinst
- SOR Controls Group
- Supmea
- Teledyne ISCO
- Temposonics
- Tracerco
- UWT
- Van Essen Instruments
- Veeder-Root
- Vega
Frequently asked questions
What is the difference between a radar level transmitter and an ultrasonic one?
Radar uses electromagnetic waves and is more stable in the presence of foam, dense vapours or high temperatures, because it does not depend on the speed of sound in air. The ultrasonic type is accurate enough for clean liquids in normal conditions, but can give wrong readings in dusty, foamy or heavily steamy environments.
How do I choose a level transmitter for an industrial tank?
Start from the type of medium measured and the conditions inside — foam, agitation, deposits — then set the measuring range based on the total height of the tank, not just the normal working level. The chemical compatibility of the wetted materials with the product finally decides the technology and the exact model.
What must be sent for a quotation for level transmitters?
The type of medium, the tank height, the conditions inside, the required contact material and the desired output type are enough for a correct recommendation. Delivery is confirmed only at order, typically 1–4 weeks, depending on the technology and the manufacturer chosen.
Can a level transmitter be fitted on a tank with abrasive or viscous contents?
Yes, but non-contact technology (radar) is generally preferred for abrasive or viscous products, because it avoids mechanical wear of an immersed probe. If a contact sensor is chosen anyway, the probe material must be selected specifically for abrasion resistance.