An industrial analyzer is an instrument that measures, continuously or periodically, a chemical or physical property of a fluid, such as gas concentration, pH or conductivity, and sends the measured value to a control or display system. It is used for water quality monitoring, gas leak detection and emissions control.

The measuring principle differs with the property analysed: electrochemical or catalytic sensors detect the concentration of specific gases through their reaction with an electrode or a sensitive element, pH sensors use a glass electrode sensitive to hydrogen ions, and conductivity sensors measure the ability of a liquid to conduct electric current. There are portable versions, for spot checks or emergency interventions, and fixed versions, permanently installed in the process, with continuous transmission of the value to the automation system.

An analyzer suited to the industrial environment is recognised by the long-term stability of the measurement, that is the sensor drift between two calibrations, by ease of calibration and maintenance, and by the compatibility of the materials in contact with the measured fluid, especially for corrosive substances. The protection class of the housing and, where applicable, ATEX certification for flammable gas detectors are essential in hazardous areas. A standard output, 4-20mA or a digital protocol, for integration with the existing control system avoids improvised connection solutions.

How to choose

Property or substance to be measured

The type of analyzer, specific gas, pH, conductivity, dissolved oxygen and so on, must be chosen exactly for the substance or property being monitored; a generic or unsuitable sensor can give wrong readings without the operator noticing.

Measuring range and accuracy

The measuring range must comfortably cover the real process interval, and the required accuracy depends on the purpose: a safety alarm has different requirements from a measurement used for process optimisation.

Installation environment (fixed or portable)

Continuous monitoring of a fixed process point requires a permanently installed analyzer with an output to the control system, while spot checks or emergency interventions are done more efficiently with a portable device.

Compatibility of materials with the measured fluid

Corrosive or aggressive fluids require electrodes and sensor bodies made of resistant materials; the wrong choice leads to rapid deterioration of the sensitive element and incorrect readings.

Calibration frequency required

Some measuring technologies drift faster than others and require frequent calibration; easy access to the sensor for calibration or replacement reduces monitoring downtime.

Certification for hazardous areas (ATEX)

Flammable or explosive gas detectors installed in classified areas must have ATEX certification appropriate to that area, otherwise the installation is not compliant.

What to send for a quotation

  • The property or substance to be measured (specific gas, pH, conductivity and so on).
  • The measuring range needed and the accuracy required by the application.
  • The type of installation wanted (fixed, with output to automation, or portable).
  • The measured fluid or medium and the working temperature.
  • The need for ATEX certification, if the area is classified as explosive.
  • The required quantity and the desired deadline.

Typical applications

  • Water quality
  • Gas leak detection
  • Emissions control
  • Chemical processes

Maintenance and spare parts

The sensitive elements, electrodes, membranes and measuring cells, are the components that wear or become contaminated most often and need periodic cleaning or replacement. Regular calibration with reference solutions or gases is essential to maintain accuracy; the frequency depends on the technology and on how aggressive the measured medium is. The spare parts requested most often are the electrode or the sensor itself and the calibration solutions.

Brands we quote for this product type

Frequently asked questions

What is the difference between industrial analyzers and pressure or temperature sensors?

The analyzer measures a chemical property or the composition of a fluid, such as gas concentration, pH or conductivity, through a specific reaction or interaction with the sensitive element. Pressure or temperature sensors measure direct physical quantities, with much simpler measuring principles and, generally, lower calibration needs.

How do I choose an industrial analyzer for a new application?

Start from the exact substance or property to be measured and the real process range, then check whether the available technology is compatible with the measured fluid, including at temperature and chemical aggressiveness. The acceptable calibration frequency and the need for an output to the automation system complete the choice.

What information is needed for a quotation for industrial analyzers, and how long does delivery take?

We need the substance or property to be measured, the measuring range, the type of installation and the working fluid. Delivery is confirmed at order, typically 1–4 weeks, depending on the manufacturer and on the complexity of the initial calibration of the device.

How often should an industrial analyzer be calibrated?

The frequency depends on the sensor technology and on how aggressive the measured medium is; some electrochemical cells drift within a few months, others last a year or more. It is useful to have a calibration plan set from commissioning, with reference solutions or gases suited to the measured range.

Updated: 2026-11-12